Schumacher INC-14825A Calculating Charge Time, Hydrometer or Electronic Method, Example

Page 12

10.CALCULATING CHARGE TIME

The Hydrometer or Electronic Method

To find the time needed to fully charge your battery, determine the battery’s charge level with a hydrometer or electronic Percent-of-Charge Tester. The following table will help you convert hydrometer readings to percent of charge values.

SPECIFIC GRAVITY

PERCENT OF CHARGE

PERCENT OF CHARGE

 

 

NEEDED

1.265

100%

0%

1.225

75%

25%

1.155

25%

75%

1.120

0%

100%

When you know the percent of charge and the Amp Hour (AH) rating of your battery, you can calculate the approximate time needed to bring your battery to a full charge.

To convert Reserve Capacity to Amp Hours, divide Reserve Capacity by 2, and add 16:

Example:

Amp Hour Rating = Reserve Capacity + 16 2

NOTE: The Reserve Capacity can be obtained from the battery specification sheet or the owner’s manual.

To calculate the time needed for a charge:

1.Find the percent of charge needed. (A battery at 50 percent charge that will be charged to 100 percent needs another 50 percent (.50)).

2.Multiply the Amp Hour Rating by the charge needed (.50) and divide by the charger setting (17 amps average).

3.Multiply the results by 1.25 and you will have the total time needed, in hours, to bring the battery to full charge.

4.Add an additional hour for a deep-cycle battery.

Example:

Amp Hour Rating x % of charge needed x 1.25 = hours of charge Charger Setting

100 (AH Rating) x .50 (charge needed) x 1.25 = 3.676 hours 17 (Charger Setting)

100 x .50 x 1.25 = 3.676

17

You would need to charge your 100-Ampere Hour Battery for a little more than 3 hours using the above example.

8

Image 12
Contents Guide D’UTILISATION Page Índice Table DES Matières Page Important Safety Instructions Risk of electric shock or firePersonal Precautions Risk of explosive gases Preparing to ChargeRisk of explosion and contact with battery acid DC Connection PrecautionsCharger Location Follow These precautions When connecting BatteryBattery Charging AC Connections Features Automatic Temperature CompensationOperating Instructions Thermal RunawayAutomatic Charging Mode Desulfation ModeMaintain Mode Float-Mode Monitoring Power Saving ModeCalculating Charge Time Hydrometer or Electronic MethodExample To calculate the time needed for a chargeMaintenance Instructions Troubleshooting Problem Possible Cause REASON/SOLUTIONStorage Instructions Problem Possible Cause REASON/SOLUTION SpecificationsBefore Returning for Repairs Page Advertencia Instrucciones Importantes DE Seguridad El riesgo de descarga eléctrica o incendioPrecauciones Personales Riesgo de gases explosivos Preparación Para LA CargaUbicación DEL Cargador Riesgo de contacto con el ácido de la bateríaPrecauciones DE Conexión EN CC Siga Estas Indicaciones Cuando Conecte LA BateriaCarga DE BATERÍA, Conexiones DE CA Características Instrucciones DE OperaciónCompensación de Temperatura Automática Escape termalCarga Modo de carga automáticaCarga anulada Modo de desulfataciónModo de Ahorro de Energía Notas generales sobre la cargaEjemplo Instrucciones DE Mantenimiento Instrucciones DE AlmacenajeLocalización Y Solución DE Problemas Posible Causa LED CargandoAntes DE Devolver a Reparaciones EspecificacionesEléctricas MecánicasPage Page Consignes DE Sécurité Importantes Risque de choc électrique ou d’incendiePrécautions Personnelles Risque de gaz explosifs Préparation Pour LE ChargementEmplacement DU Chargeur Le risque de contact avec l’acide de batteriePrécautions SUR LA Connexion C.C Suivre CES Précautions EN Raccordant LA BatterieCaractéristiques Consignes D’UTILISATIONCompensation Automatique de Température Fugueur ThermalMode de chargement automatique Mode de désulfatationMode Entretien Contrôlant le Mode de monitor Le chargementLe Mode Économique ExempleConsignes D’ENTRETIEN Directives D’ENTREPOSAGETableau DE Dépannage Problème Cause Possible RAISON/SOLUTION Avant DE L’ENVOYER Pour RéparationDonnées d’alimentation Données mécaniquesConnexions