HP xw2x220c Blade manual Power quality, Power considerations, Factors affecting power quality

Page 32

Power quality

Most HP products are designed to operate over a wide range of voltages and frequencies. The products are tested and shown to comply with certain EMC Specifications. However, damage can occur if these ranges are exceeded. Severe electrical disturbances can exceed the design specifications of the equipment.

Factors affecting power quality

Common factors that affect power quality include the following:

Electrical storms

Utility service brownouts or sags

Faults in the power generation equipment

Large inductive loads, such as motors and welders

Load fluctuations occurring within the facility distribution system

Loose connections or other faults in the distribution system wiring

Power system protection

HP products can be protected from the sources of many of these electrical disturbances by using the following:

A dedicated power distribution system

Power conditioning equipment

Over- and under-voltage protection and detection circuits

Lightning arresters on power cables to protect equipment against electrical storms

The power distribution system is designed to provide immunity to power interruptions. However, testing cannot conclusively rule out loss of service. Use the following guidelines to provide the best possible performance of power distribution systems for HP computer equipment:

Dedicated power source—Isolates the power distribution system from other circuits in the facility.

Online uninterruptible power supply (UPS)—Keeps input voltage to devices constant and should be considered if outages of one-half cycle or more are common.

Auto-start generators–provide backup power to the UPS.

Missing-phase and low-voltage detectors—initiate a transfer of the UPS to generator power when a severe power interruption occurs. For peripheral equipment, these devices are recommended but optional.

For each situation, refer to qualified contractors or consultants.

Power considerations

Power is best managed within the rack by the use of one or more rack-mounted PDUs. Depending on the configuration, it may be necessary or preferable to use multiple PDUs to connect all devices inside the rack.

Power requirements and considerations 32

Image 32
Contents HP BladeSystem c-Class Site Planning Guide Intended audience Contents Conversion factors and formulas Technical support Related documentation IntroductionAbout this document HP site planning assistance General site preparation guidelinesAshrae guidelines for site planning Site planning considerations Computer room preparationPage Air conditioning system specifications Basic air distribution systemsCabling requirements Air conditioning ductsAverage floor loading Floor loadingRaised floor loading Computer room safety Installation and maintenance precautionsFire protection Fire suppressionWorking space for component access Lighting requirements for equipment servicingEnvironmental requirements Environmental elementsHumidity level Dust and pollutionMetallic particulate contamination Acoustic noise specification Electrostatic discharge preventionRecommended operating environment AshraeAirflow requirements Space requirementsBlanking panels HP Rack Airflow Optimization KitEquipment clearance and floor loading Delivery space requirementsOperational space requirements Floor plan grid Rack and accessory footprints HP BladeSystem enclosure environmental specificationsFront door clearance Environmental requirements Environmental requirements Best practices for deployment in rows Rack placement and arrangement for proper airflow Third-party racksRack tie-down option kit Electrical factors Power requirements and considerationsPower requirements Power consumption Electrical load requirements circuit breaker sizing Power quality Power considerationsFactors affecting power quality Power system protectionPower options Power redundancyNon-redundant power Wire selectionDistribution hardware Line voltage selectionGrounding requirements Grounding systemsRaceway systems electrical conduits Lahj Building distributionPower distribution safety grounding Lahj Power panel groundComputer safety ground Dual power source groundingCabinet performance grounding high frequency ground Raised floor high-frequency noise groundingEquipment grounding implementation details System installation guidelinesWiring connections Power configuration Dynamic Power CappingHP BladeSystem enclosure single-phase power configuration Data communications cablesPower requirements and considerations Power requirements and considerations Power requirements and considerations PDU installation C7000 PDU exampleC3000 PDU example HP BladeSystem c7000 Enclosure three-phase AC configuration HP BladeSystem enclosure DC power configuration HP BladeSystem c7000 Enclosure DC configurationHP BladeSystem c3000 Enclosure DC configuation Power supply specificationsSingle-phase HP 2250W Power Supply specification Specification Value Specification Value DC power supply specification Hardware specifications and requirements Enclosure specificationsHP BladeSystem c7000 Enclosure specifications HP BladeSystem c3000 Enclosure specificationsHP 10000 G2 rack specifications Rack requirementsRack-free environment requirements Configuration scenarios Example configurationsExample minimum configuration Example typical configurationExample maximum configuration Estimating power and cooling Estimating total weight Preparing for installation Preparing for installation General component placement guidelines Additional rack considerationsRack configuration software Sample installation schedule Sample checklistsIs there a completed floor plan? Delivery survey Page Formulas Conversion factors and formulasConversion factors HP contact information Technical supportBefore you contact HP Acronyms and abbreviations UPS Apparent power GlossaryKVA Index Site planning assistance from HP

xw2x220c Blade specifications

The HP xw2x220c Blade is designed for organizations that require a high-performance, space-efficient computing solution. This blade server epitomizes the commitment to enhancing data center efficiency and maximizing computing power without compromising on reliability.

One of the standout features of the HP xw2x220c Blade is its compact form factor, which enables organizations to fit a substantial amount of computing power in a small footprint. This is particularly beneficial for businesses with limited space, as they can host more servers within the same physical environment. The blade is optimized for virtualization, allowing it to handle multiple workloads simultaneously, which translates to cost savings and better resource utilization.

The server is powered by advanced Intel Xeon processors, ensuring efficient processing capabilities for demanding applications. The HP xw2x220c Blade supports multiple CPU options, allowing organizations to select the configuration that best meets their workload requirements. Leveraging Intel's latest technologies, it offers enhanced performance while maintaining energy efficiency, which is a critical consideration in today’s environmentally conscious technological landscape.

In terms of memory, the xw2x220c Blade supports high-capacity DDR4 RAM, which enhances data access speeds and ensures smooth operation even during heavy loads. The architecture of the blade also includes advanced cooling technology that optimizes airflow to maintain optimal temperatures, thereby prolonging hardware lifespan and reliability.

Network connectivity is a vital feature, and the HP xw2x220c Blade offers multiple Ethernet ports for flexible networking options, as well as support for fibre channel connections. This enables seamless integration into existing network configurations, ensuring high-speed data transfer rates that are crucial for real-time applications.

Security features are also integrated into the HP xw2x220c Blade, including options for secure boot, system integrity verification, and advanced encryption capabilities. These attributes protect sensitive data from unauthorized access and potential breaches, which is essential for organizations dealing with confidential information.

In conclusion, the HP xw2x220c Blade is a formidable choice for businesses seeking a compact, powerful, and efficient computing solution. Its combination of advanced processing capabilities, extensive memory support, flexible networking options, and robust security features makes it well-suited for a variety of applications, making it an essential component for modern data centers.