HP xw2x220c Blade manual Site planning assistance from HP

Page 73

L

line voltage 34

M

main building electrcial ground

36

maintenance precautions 13

 

metallic particular contamination

16

N

non-redundant power 34

O

Onboard Administrator 45

operating environment, recommended 18 operational space requirements 20

P

phone numbers 67 power cap 39

power configurations 39, 46

power distribution safety grounding 36 power options 33

power panel ground 36 power quality 32 power redundancy 33 power requirements 29

power supply specification 47, 50

R

raceway systems 35 Rack Airflow Kit 19 rack footprints 22 rack installation 26, 27 rack options 53

rack placement, additional considerations 27 rack requirements 52

rack stability 58

rack tie-down option kit 28 rack warnings 58

rack-free environment requirements 53 raised floor grounding 37

raised floor loading 12

recommneded operating environment 18 related documents 6

required information 67 requirements, airflow 58 requirements, rack-free environment 53

requirements, space 58

S

safety considerations

58

 

 

safety, computer room

13

 

 

single-phase AC configuration

39

site planning assistance from HP

7

site planning considerations

8, 62

space requirements 19

 

 

space requirements, delivery

20

space requirements, operational

20

specifications 47, 50, 51

 

 

support 67

 

 

 

T

technical support 67 telephone numbers 67 third-party racks 27 three-phase AC configuration 45

W

warnings 20, 37, 53, 58 website, HP 67 weight, estimating 57 wire selection 34 wiring connections 38

Index 73

Image 73
Contents HP BladeSystem c-Class Site Planning Guide Intended audience Contents Conversion factors and formulas Technical support About this document IntroductionRelated documentation Ashrae guidelines for site planning General site preparation guidelinesHP site planning assistance Computer room preparation Site planning considerationsPage Basic air distribution systems Air conditioning system specificationsAir conditioning ducts Cabling requirementsRaised floor loading Floor loadingAverage floor loading Installation and maintenance precautions Computer room safetyFire protection Fire suppressionLighting requirements for equipment servicing Working space for component accessEnvironmental elements Environmental requirementsHumidity level Dust and pollutionMetallic particulate contamination Electrostatic discharge prevention Acoustic noise specificationAshrae Recommended operating environmentSpace requirements Airflow requirementsBlanking panels HP Rack Airflow Optimization KitOperational space requirements Delivery space requirementsEquipment clearance and floor loading Floor plan grid HP BladeSystem enclosure environmental specifications Rack and accessory footprintsFront door clearance Environmental requirements Environmental requirements Best practices for deployment in rows Third-party racks Rack placement and arrangement for proper airflowRack tie-down option kit Power requirements Power requirements and considerationsElectrical factors Power consumption Electrical load requirements circuit breaker sizing Power considerations Power qualityFactors affecting power quality Power system protectionPower redundancy Power optionsWire selection Non-redundant powerDistribution hardware Line voltage selectionGrounding systems Grounding requirementsRaceway systems electrical conduits Lahj Building distributionPower panel ground Power distribution safety grounding LahjComputer safety ground Dual power source groundingRaised floor high-frequency noise grounding Cabinet performance grounding high frequency groundWiring connections System installation guidelinesEquipment grounding implementation details Dynamic Power Capping Power configurationHP BladeSystem enclosure single-phase power configuration Data communications cablesPower requirements and considerations Power requirements and considerations Power requirements and considerations C7000 PDU example PDU installationC3000 PDU example HP BladeSystem c7000 Enclosure three-phase AC configuration HP BladeSystem c7000 Enclosure DC configuration HP BladeSystem enclosure DC power configurationSingle-phase HP 2250W Power Supply specification Power supply specificationsHP BladeSystem c3000 Enclosure DC configuation Specification Value Specification Value DC power supply specification Enclosure specifications Hardware specifications and requirementsHP BladeSystem c7000 Enclosure specifications HP BladeSystem c3000 Enclosure specificationsRack requirements HP 10000 G2 rack specificationsRack-free environment requirements Example configurations Configuration scenariosExample minimum configuration Example typical configurationExample maximum configuration Estimating power and cooling Estimating total weight Preparing for installation Preparing for installation Additional rack considerations General component placement guidelinesRack configuration software Sample checklists Sample installation scheduleIs there a completed floor plan? Delivery survey Page Conversion factors Conversion factors and formulasFormulas Before you contact HP Technical supportHP contact information Acronyms and abbreviations UPS Glossary Apparent powerKVA Index Site planning assistance from HP

xw2x220c Blade specifications

The HP xw2x220c Blade is designed for organizations that require a high-performance, space-efficient computing solution. This blade server epitomizes the commitment to enhancing data center efficiency and maximizing computing power without compromising on reliability.

One of the standout features of the HP xw2x220c Blade is its compact form factor, which enables organizations to fit a substantial amount of computing power in a small footprint. This is particularly beneficial for businesses with limited space, as they can host more servers within the same physical environment. The blade is optimized for virtualization, allowing it to handle multiple workloads simultaneously, which translates to cost savings and better resource utilization.

The server is powered by advanced Intel Xeon processors, ensuring efficient processing capabilities for demanding applications. The HP xw2x220c Blade supports multiple CPU options, allowing organizations to select the configuration that best meets their workload requirements. Leveraging Intel's latest technologies, it offers enhanced performance while maintaining energy efficiency, which is a critical consideration in today’s environmentally conscious technological landscape.

In terms of memory, the xw2x220c Blade supports high-capacity DDR4 RAM, which enhances data access speeds and ensures smooth operation even during heavy loads. The architecture of the blade also includes advanced cooling technology that optimizes airflow to maintain optimal temperatures, thereby prolonging hardware lifespan and reliability.

Network connectivity is a vital feature, and the HP xw2x220c Blade offers multiple Ethernet ports for flexible networking options, as well as support for fibre channel connections. This enables seamless integration into existing network configurations, ensuring high-speed data transfer rates that are crucial for real-time applications.

Security features are also integrated into the HP xw2x220c Blade, including options for secure boot, system integrity verification, and advanced encryption capabilities. These attributes protect sensitive data from unauthorized access and potential breaches, which is essential for organizations dealing with confidential information.

In conclusion, the HP xw2x220c Blade is a formidable choice for businesses seeking a compact, powerful, and efficient computing solution. Its combination of advanced processing capabilities, extensive memory support, flexible networking options, and robust security features makes it well-suited for a variety of applications, making it an essential component for modern data centers.