WARNING: To reduce the risk of personal injury or damage to the equipment, always load the heaviest item first from the bottom of the rack up. This makes the rack bottom-heavy and helps prevent the rack from becoming unstable. Refer to Configuration Factors.

WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that:

The leveling feet are extended to the floor.

The full weight of the rack rests on the leveling feet.

The stabilizing feet are attached to the rack if it is a single-rack installation.

The racks are coupled together in multiple-rack installations.

Only one component is extended at a time. A rack may become unstable if more than one component is extended for any reason.

CAUTION: To reduce the risk of damage to the equipment when installing third-party options:

Do not permit optional equipment to impede airflow around the enclosure or to increase the internal rack temperature beyond the maximum allowable limits.

Do not exceed the manufacturer’s TMRA.

IMPORTANT: HP strongly recommends that you configure the rack using the HP eCo-Enterprise Configurator, which provides factory default racking. The latest version of this software is available on the HP website (http://h30099.www3.hp.com/eGlue/eco/begin.do).

When loading your components, observe the general guidelines:

For detailed instructions on installing specific component or third-party hardware, see the user documentation that shipped with that component.

Before installing components into the rack, see the "Electrostatic Discharge ("Electrostatic discharge prevention" on page 17)" section.

Use the configuration prepared by the eCo Enterprise Configurator as a guideline for installation components.

Load the heavier components first from the bottom of the rack.

Be sure to balance the weight load among bayed racks. For example, if you have several UPS units and several servers, do not load all of the UPS units into one rack. Instead, distribute them evenly in the bottom positions of each rack.

Allow a minimum clearance of 76 cm (30 in) between the wall and the rear of the rack to provide adequate access for installation and service.

Rack configuration software

To help you plan your rack configuration more efficiently, HP provides eCo-Enterprise Configurator, a powerful web-based service that enables you to build, store, and export end-to-end rack configurations. HP strongly recommends that you configure the rack using the eCo-Enterprise Configurator, which provides factory default racking. The latest version of the software is available on the HP website (http://h30099.www3.hp.com/eGlue/eco/begin.do).

Preparing for installation 61

Image 61
Contents HP BladeSystem c-Class Site Planning Guide Intended audience Contents Conversion factors and formulas Technical support About this document IntroductionRelated documentation Ashrae guidelines for site planning General site preparation guidelinesHP site planning assistance Computer room preparation Site planning considerationsPage Basic air distribution systems Air conditioning system specificationsAir conditioning ducts Cabling requirementsRaised floor loading Floor loadingAverage floor loading Installation and maintenance precautions Computer room safetyFire protection Fire suppressionLighting requirements for equipment servicing Working space for component accessEnvironmental elements Environmental requirementsHumidity level Dust and pollutionMetallic particulate contamination Electrostatic discharge prevention Acoustic noise specificationAshrae Recommended operating environmentSpace requirements Airflow requirementsBlanking panels HP Rack Airflow Optimization KitOperational space requirements Delivery space requirementsEquipment clearance and floor loading Floor plan grid HP BladeSystem enclosure environmental specifications Rack and accessory footprintsFront door clearance Environmental requirements Environmental requirements Best practices for deployment in rows Third-party racks Rack placement and arrangement for proper airflowRack tie-down option kit Power requirements Power requirements and considerationsElectrical factors Power consumption Electrical load requirements circuit breaker sizing Power considerations Power qualityFactors affecting power quality Power system protectionPower redundancy Power optionsWire selection Non-redundant powerDistribution hardware Line voltage selectionGrounding systems Grounding requirementsRaceway systems electrical conduits Lahj Building distributionPower panel ground Power distribution safety grounding LahjComputer safety ground Dual power source groundingRaised floor high-frequency noise grounding Cabinet performance grounding high frequency groundWiring connections System installation guidelinesEquipment grounding implementation details Dynamic Power Capping Power configurationHP BladeSystem enclosure single-phase power configuration Data communications cablesPower requirements and considerations Power requirements and considerations Power requirements and considerations C7000 PDU example PDU installationC3000 PDU example HP BladeSystem c7000 Enclosure three-phase AC configuration HP BladeSystem c7000 Enclosure DC configuration HP BladeSystem enclosure DC power configurationSingle-phase HP 2250W Power Supply specification Power supply specificationsHP BladeSystem c3000 Enclosure DC configuation Specification Value Specification Value DC power supply specification Enclosure specifications Hardware specifications and requirementsHP BladeSystem c7000 Enclosure specifications HP BladeSystem c3000 Enclosure specificationsRack requirements HP 10000 G2 rack specificationsRack-free environment requirements Example configurations Configuration scenariosExample minimum configuration Example typical configurationExample maximum configuration Estimating power and cooling Estimating total weight Preparing for installation Preparing for installation Additional rack considerations General component placement guidelinesRack configuration software Sample checklists Sample installation scheduleIs there a completed floor plan? Delivery survey Page Conversion factors Conversion factors and formulasFormulas Before you contact HP Technical supportHP contact information Acronyms and abbreviations UPS Glossary Apparent powerKVA Index Site planning assistance from HP

xw2x220c Blade specifications

The HP xw2x220c Blade is designed for organizations that require a high-performance, space-efficient computing solution. This blade server epitomizes the commitment to enhancing data center efficiency and maximizing computing power without compromising on reliability.

One of the standout features of the HP xw2x220c Blade is its compact form factor, which enables organizations to fit a substantial amount of computing power in a small footprint. This is particularly beneficial for businesses with limited space, as they can host more servers within the same physical environment. The blade is optimized for virtualization, allowing it to handle multiple workloads simultaneously, which translates to cost savings and better resource utilization.

The server is powered by advanced Intel Xeon processors, ensuring efficient processing capabilities for demanding applications. The HP xw2x220c Blade supports multiple CPU options, allowing organizations to select the configuration that best meets their workload requirements. Leveraging Intel's latest technologies, it offers enhanced performance while maintaining energy efficiency, which is a critical consideration in today’s environmentally conscious technological landscape.

In terms of memory, the xw2x220c Blade supports high-capacity DDR4 RAM, which enhances data access speeds and ensures smooth operation even during heavy loads. The architecture of the blade also includes advanced cooling technology that optimizes airflow to maintain optimal temperatures, thereby prolonging hardware lifespan and reliability.

Network connectivity is a vital feature, and the HP xw2x220c Blade offers multiple Ethernet ports for flexible networking options, as well as support for fibre channel connections. This enables seamless integration into existing network configurations, ensuring high-speed data transfer rates that are crucial for real-time applications.

Security features are also integrated into the HP xw2x220c Blade, including options for secure boot, system integrity verification, and advanced encryption capabilities. These attributes protect sensitive data from unauthorized access and potential breaches, which is essential for organizations dealing with confidential information.

In conclusion, the HP xw2x220c Blade is a formidable choice for businesses seeking a compact, powerful, and efficient computing solution. Its combination of advanced processing capabilities, extensive memory support, flexible networking options, and robust security features makes it well-suited for a variety of applications, making it an essential component for modern data centers.