HP xw2x220c Blade manual Hardware specifications and requirements, Enclosure specifications

Page 51

Hardware specifications and requirements

Enclosure specifications

The HP ProLiant c-Class enclosure specifications are provided for site planning purposes. For the latest specfications, see the HP website (http://www.hp.com/go/bladesystem/documentation).

HP BladeSystem c7000 Enclosure specifications

Specification

Value

 

 

Product dimensions

 

 

 

Height

442.0 mm (17.4 in)

 

 

Depth

813.0 mm (32.0 in)

 

 

Width

447.0 mm (17.6 in)

 

 

Shipping dimensions

 

 

 

Height

759.00 mm (29.88 in)

 

 

Depth

1013.00 mm (39.88 in)

 

 

Width

607.00 mm (23.88 in)

 

 

Single-phase enclosure weight*

 

 

 

Unboxed

54.9 kg (121.0 lb)

 

 

Shipping

74.4 kg (164.0 lb)

 

 

Three-phase enclosure weight*

 

 

 

Unboxed

68.0 kg (150.0 lb)

 

 

Shipping

87.5 kg (193.0 lb)

 

 

Maximum enclosure weight

 

 

 

Unboxed

204.0 kg (450.0 lb)

 

 

Shipping

223.6 kg (493.0 lb)

 

 

* No components installed.

 

HP BladeSystem c3000 Enclosure specifications

Specification

Value

 

 

Product dimensions

 

 

 

Height

264.50 mm (10.42 in)

 

 

Depth

835.00 mm (32.88 in)

 

 

Width

485.00 mm (19.10 in)

 

 

Shipping dimensions

 

 

 

Hardware specifications and requirements 51

Image 51
Contents HP BladeSystem c-Class Site Planning Guide Intended audience Contents Conversion factors and formulas Technical support Introduction About this documentRelated documentation General site preparation guidelines Ashrae guidelines for site planningHP site planning assistance Computer room preparation Site planning considerationsPage Basic air distribution systems Air conditioning system specificationsAir conditioning ducts Cabling requirementsFloor loading Raised floor loadingAverage floor loading Fire suppression Computer room safetyInstallation and maintenance precautions Fire protectionLighting requirements for equipment servicing Working space for component accessDust and pollution Environmental requirementsEnvironmental elements Humidity levelMetallic particulate contamination Electrostatic discharge prevention Acoustic noise specificationAshrae Recommended operating environmentHP Rack Airflow Optimization Kit Airflow requirementsSpace requirements Blanking panelsDelivery space requirements Operational space requirementsEquipment clearance and floor loading Floor plan grid HP BladeSystem enclosure environmental specifications Rack and accessory footprintsFront door clearance Environmental requirements Environmental requirements Best practices for deployment in rows Third-party racks Rack placement and arrangement for proper airflowRack tie-down option kit Power requirements and considerations Power requirementsElectrical factors Power consumption Electrical load requirements circuit breaker sizing Power system protection Power qualityPower considerations Factors affecting power qualityPower redundancy Power optionsLine voltage selection Non-redundant powerWire selection Distribution hardwareBuilding distribution Grounding requirementsGrounding systems Raceway systems electrical conduits LahjDual power source grounding Power distribution safety grounding LahjPower panel ground Computer safety groundRaised floor high-frequency noise grounding Cabinet performance grounding high frequency groundSystem installation guidelines Wiring connectionsEquipment grounding implementation details Data communications cables Power configurationDynamic Power Capping HP BladeSystem enclosure single-phase power configurationPower requirements and considerations Power requirements and considerations Power requirements and considerations C7000 PDU example PDU installationC3000 PDU example HP BladeSystem c7000 Enclosure three-phase AC configuration HP BladeSystem c7000 Enclosure DC configuration HP BladeSystem enclosure DC power configurationPower supply specifications Single-phase HP 2250W Power Supply specificationHP BladeSystem c3000 Enclosure DC configuation Specification Value Specification Value DC power supply specification HP BladeSystem c3000 Enclosure specifications Hardware specifications and requirementsEnclosure specifications HP BladeSystem c7000 Enclosure specificationsRack requirements HP 10000 G2 rack specificationsRack-free environment requirements Example typical configuration Configuration scenariosExample configurations Example minimum configurationExample maximum configuration Estimating power and cooling Estimating total weight Preparing for installation Preparing for installation Additional rack considerations General component placement guidelinesRack configuration software Sample checklists Sample installation scheduleIs there a completed floor plan? Delivery survey Page Conversion factors and formulas Conversion factorsFormulas Technical support Before you contact HPHP contact information Acronyms and abbreviations UPS Glossary Apparent powerKVA Index Site planning assistance from HP