HP Web-Based Enterprise Services 4.5 Errors When the Director or WCCProxy is Restarted Too Soon

Page 21

Overall WEBES Release Notes

1.6 WEBES Known Issues

1.6.1.12Errors When the Director or WCCProxy is Restarted Too Soon

This release note applies to both the desta Director and WCCproxy services.

After the command to stop one of these services completes, such as desta stop or

net stop desta_service, the operating system sometimes requires a few more seconds to stop all WEBES related processes and release their resources (such as sockets). On rare occasions, restarting too soon after stopping can result in errors in the Director log file, and the services also may fail to restart.

To avoid this issue, wait 10 more seconds before restarting, after the command completes.

In Windows, this means you also must avoid cycling the services using the one-step “restart” option available within the Services Manager, because it stops and restarts a service too quickly. Instead, take separate steps in the Services Manager to stop the service, wait 10 seconds, and then start the service.

1.6.1.13 Service Cockpit Compatibility

Hewlett-Packard Service Cockpit is not compatible with WEBES 4.2 or higher. In other words, Service Cockpit does not successfully launch WEBES tools on systems running WEBES version 4.2 or higher, including this version.

1.6.1.14 Upgrading Versions Older Than Two Releases

If you have already installed a WEBES version that is more than two releases older than the latest version, you need to uninstall the existing version and install the latest version.

There are known problems with migrating previous data when upgrading older versions, which may result in undesired changes in notification preferences, as well as other issues.

1.6.1.15 WEBES Uninstall Affects ISEE Client WCCProxy

WEBES and the ISEE Client both require the WCCProxy. In some cases, you may decide to uninstall WEBES but leave an ISEE Client on the system.

If so, you must manually restart the WCCProxy after WEBES uninstallation, because removing WEBES will leave the WCCProxy in a stopped state:

Windows:

C:\>net start wccproxy

UNIX variants:

#

/usr/sbin/wccproxy start

OpenVMS:

$

wccproxy start

Rev. 9/8/06

Web-Based Enterprise Services Release Notes 1–13

Image 21
Contents Software Version Web-Based Enterprise Services Release NotesIi Web-Based Enterprise Services Release Notes Web-Based Enterprise Services Release Notes Page Contents System Event Analyzer ContentsComputer Crash Analysis Tool Further Information Overall Webes Release Notes Summary Hardware RequirementsOverall Webes Release Notes Summary Overall Webes Release Notes Operating System Requirements Operating System RequirementsTest Environment Overall Webes Release Notes Test EnvironmentWindows Overall Webes Release Notes 1.5 New in this Release New in this ReleaseRedHat Linux not Patched OpenVMSIntegrity Servers Overall Webes Release Notes New in this ReleaseMiscellaneous Virtual Library System VLSOverall Webes Release Notes 1.5 New in this Release General Webes Issues Webes Known IssuesInstalling Webes on Unsupported Platforms Overall Webes Release Notes Webes Known IssuesError During Reading of Obligation Information Webes Installation Issue on ISEE-OSEM HostIntermittent Socket Errors Webes Configuration Information Not Restored Webes Output Log Files Grow Without BoundWorkaround Webes Temporary Files Use Disk Space Backward CompatibilityWorkarounds Director Process Stopping When Out of Memory Upgrade Requires Reinitialized LogDirector Process Not Responding Service Cockpit Compatibility Errors When the Director or WCCProxy is Restarted Too SoonWebes Uninstall Affects Isee Client WCCProxy Upgrading Versions Older Than Two ReleasesChanging Time Zone Causes Incorrect Report Time Errors From desta siclqsap on CommandsClassNotFoundExceptions in Director Log Windows Webes IssuesInstallation Prompts When File Fails to Delete Webes Installation Appears to HangAddition Webes Configuration is Not Migrated for Windows ItaniumCcat Not Available on Windows Itanium Uninstall of Previous Webes May Hang Installation Internal ErrorDesta msg -chgport Command Path Update Required on Terminal Server InstallationWindows Itanium Webes Removal Leaves Files Behind Linux Webes Issues Segmentation Fault Error MessageDirector May Require Restart Set ODS-5 Attributes Before Issuing Webes CLI Commands OpenVMS Webes IssuesCannot Get Local Host Name Jfex ErrorsContinuous CPU Usage After Daylight Savings Time Change New OpenVMS Patch Removal FeatureUpgrade Requires Same Node as Install Alternate Boot Start and Stop MethodsCannot Get Smtp Notification on OpenVMS Run the following commands to stop the Smtp debug logging Overall Webes Release Notes Further Information Further InformationOverall Webes Release Notes 1.7 Further Information System Event Analyzer System Event Analyzer Summary Supported ProductsKZPSC/KZPAC/KZPBA/KZPCM/KZPSA/KZPCC/KSPEA System Event Analyzer Supported ProductsSEA Known Issues General SEA IssuesSystem Event Analyzer SEA Known Issues File Not Found Error In Desta Log File Serial Number Prevents Rules from WorkingFields Contain Unavailable Transferring Files with FTP Duplicate Callouts with both DECevent and Webes InstalledInsert the following code at the beginning of the file SEA Problem Reports Not Received by Osem SEA Command Line Interface IssuesCa Command Changed to wsea Entering CommandsWindows interprets it as With either of the following paths $ wsea n analyze svctoolscommoncommon.ca.examples*.zpd SEA Web Interface IssuesNode Name Change Causes Connection or Notification Failure Enabling Text Entry in Other Logs PaneNull-Pointer Errors High Volume of Events Hangs InterfaceNull-Pointer Errors from Large Log Files Cannot Activate a Running NodeJavaScript Error When Viewing Director Settings JavaScript ErrorsTime-out Issue Multiple Sessions using Mozilla and NetscapeTip Services Fail to StartLinux Run the following commands for all platformsMultiple Java Installs May Affect Web Interface Windows SEA Issues Old SEA Example File Names Migrated But InaccessibleSEA EVA Collections Too Big for Isee to Send to HP Execute the following command Windows Event Log May Not Grow to Configured Size Incomplete Uninstall of Older VersionXP Internet Explorer Does Not Have Java Webes Directory Tree Missing or Access Denied Test Command Generates ErrorWebes Commands Not Recognized Hewlett-Packard Service Tools Entry on Start Menu is EmptyNewly Added EVA Not Listed in SEA Web Interface Napp Error DescriptionHP-UX SEA Issues Resuming from Standby Loses Network ResourcesNo Binary Event Log Linux SEA Issues 6.1 C/C++ Runtime Libraries Version 6.1.1 or Later RequiredAdding Managed Entities Corrupts Director OpenVMS SEA Issues Insufficient Privilege or File Protection Violation Slow Response Generating Other Logs List Webes Commands Return Error Activating ImageExclude Node Names from Filespecs CAAgent Processes Created But Not DisappearingSystem Event Analyzer Further Information System Event Analyzer 2.4 Further Information Page Computer Crash Analysis Tool Ccat Known Issues General Ccat IssuesComputer Crash Analysis Tool Summary CLI Commands Not Recognized Windows Ccat IssuesComputer Crash Analysis Tool Ccat Known Issues Ccat IVP File Not FoundInability To Execute CLI Commands OpenVMS Ccat IssuesComputer Crash Analysis Tool Further Information Computer Crash Analysis Tool 3.4 Further Information