Toshiba RAV-SM800XT-E, RAV-SM560XT-E service manual Installation Place, Remote controller usage

Page 34

9-5-1. Installation Place

A place which provides the spaces around the indoor unit as shown in the above diagram.

A place where there is no obstacle near the air inlet and outlet.

A place that allows easy installation of the piping to the outdoor unit.

A place which allows the Front panel to be opened.

CAUTION

Direct sunlight or fluorescent light to the indoor unit’s wireless receiver should be avoided.

The microprocessor in the indoor unit should not be too close to RF noise sources.

(For details, see the owner’s manual.)

<Remote controller>

A place where there are no obstacles such as a curtain that may block the signal from the indoor unit.

Do not install the remote controller in a place exposed to direct sunlight or close to a heating source, such as a stove.

Keep the remote controller at least 1 m apart from the nearest TV set or stereo equipment. (This is necessary to prevent image disturbances or noise interference.)

The location of the remote controller should be determined as shown below.

<Remote controller usage>

Under Ceiling Installation

Ceiling

7

m

 

 

 

 

 

 

 

 

 

Wall

 

 

 

 

 

 

 

 

m

m

 

Remote controller

 

 

5

m

5

 

 

Reception range

 

 

 

*7

 

 

 

 

 

Reception

Remote

 

 

range

 

 

controller

9-5-2. Before Installation

<Remove the Air inlet grille>

1.Open the Air inlet grille by both hands.

2.Loosen three screws for fixing the Panel arm. Do not remove the screws at this time.

1

2

2

1

Screw

Panel arm

Fig. 9-5-3

3.First, move the Air inlet grille upward, then turn it backwards.

4.Remove the Grille stopper from the axis of the Front panel. After that, remove the Air inlet grille.

5.Remove the Panel arms from the Front panel.

 

3

Panel arm

 

 

Grille stopper

3

 

 

5

 

 

Fig. 9-5-4

9-5-3. After Installation <Install the Air inlet grille>

1.Insert the three Panel Arms on the Air inlet grille and fix each securely by screws.

Fig. 9-5-1

Console Installation

7 m

Remote controller

5

m

 

WallReception range

Reception range

5 m m *7

Remote controller

Panel arm

Fig. 9-5-5

CAUTION

The screws that fixed with Panel Arms must not

be loose.

Floor

* Axial distance

Fig. 9-5-2

NOTICE

The Paper pattern is inside the package box cover. Do not bend and dispose of it before installing.

– 32 –

Image 34
Contents AIR-CONDITIONER Contents Specifications Indoor UnitOperation characteristic curve Cooling Heating CurrentOutdoor Unit RAV-SM560AT-E RAV-SM800AT-EConstruction Views Outdoor Unit RAV-SM560AT-E Outdoor Unit RAV-SM800AT-E Systematic Refrigerating Cycle Diagram RAV-SM560XT-E / RAV-SM560AT-ERAV-SM800XT-E / RAV-SM800AT-E Indoor unitWiring Diagram Color IdentificationL N Board Specification of Electrical Parts Parts name Type SpecificationsRefrigerant R410A Safety During Installation/ServicingRefrigerant Piping Installation Piping materials and joints usedOuter diameter mm R410A R22 1 Thicknesses of annealed copper pipes Thickness mmProcessing of piping materials Clutch type Wing nut type Width·m kgf·cm ·m kgf·mRequired tools ToolsGeneral tools Conventional tools can be used 1 Configuration of refrigerant charging Recharging of RefrigerantBrazing of Pipes Activated flux Characteristics required for fluxTypes of flux Noncorrosive flux Filler FluxControl Block Diagram OperationAir volume control When power supply is resetOperation mode selection Operation DescriptionCool air discharge preventive control 1 Cold draft preventing controlLouver control Freeze preventive control Low temperature releaseHigh-temp release control Filter sign displayOperation How to set auto restart functionAuto Restart Function MotionsHow to turn off filter check lamp How to cancel auto restart functionPower failure during timer operation Filter Check LampUnder Ceiling Installation Installation ProcedureInstallation Diagram of Indoor and Outdoor Units Console InstallationPrecautions for Safety To Disconnect the Appliance from Main Power SupplyPage Accessory parts Accessory parts and Parts to be procured locallyParts to be procured locally Selection of Installation Place Avoid installing in the following placesRemote controller usage Installation PlaceRemote controller Before Installation Remove the Air inlet grilleCondition for Installation Install the indoor unitInstall the Suspension bolts Piping and Drain Hose InstallationConnect the Flexible pipe 5 to the large pipe Gas side Unit must not decline more than 15 mm in either Cutting a hole and mounting the Installation plateAxis Drain Piping Work DrainageRefrigerant Piping Tightening connection Evacuating Heat insulation For RAV-SM560AT-E model Electrical Work Final Installation Checks LED indication and code checking Environment Before troubleshooting TroubleshootingSummary of Troubleshooting Troubleshooting procedureSelf-Diagnosis by Remote Control Check Code How to use remote control in service modeJudgement and action No display in the setting at shipment Operation Troubleshooting for Each Check Code 1A error YESError 1C error* Except RAV-SM560AT-E 1E error 1D error1F error Connector normal? 20 TE, TO, TS sensor TA sensor TC, TCJ sensor Caracteristics-1 Caracteristics-2Caracteristics-3 TD sensor Caracteristics-4Compressor does not operate Inspection procedurePrimary check Cooling and heating model Are all of compressor cords normal? Detachments How to install the Air inlet grilleRemove the Panel arms from the Front panel Open 3 Cap screws and remove the screws How to remove the Drain pan Assembly Pan assembly Refrigeration How to remove the Refrigeration assemblyHow to remove the Multiblade fan Part name Procedures RemarksFan motor No. Part name Procedure Remarks DetachmentProcedure Remarks Requirement Connection with the power terminal Part name Procedure Remarks ‡ Compressor Perform works of items 1 ‚, ƒ, „, … Fan guard Remove the upper cabinet Discharge port cabinet for the heat ex Requirement Part name… Control P.C Remove the inverter box from P.C. board base Loosen the flange nut by turning clock † Compressor Perform works of items , ‚, ƒ, „, Ø4 x 10L , 2 pcs. per one reactor Product Exploded Views and Parts List Indoor Unit E-Parts AssyAir Inlet Grille Inverter 21,22 16,17 Outdoor Unit Inverter Assy, RAV-SM560AT-E 702 TE Sensor TS Sensor To Sensor TD Sensor 701 705 703 704Inverter BOX Outdoor Unit Inverter Assy, RAV-SM800AT-E