12-4. Outdoor Unit (RAV-SM800AT-E)

4

 

11

5

 

 

 

 

 

 

 

 

37

10

 

 

 

 

 

 

 

 

 

8

9

 

 

 

 

 

 

 

32

36

 

2

 

 

21,22

34 24

 

 

 

 

 

 

 

 

 

 

23

 

7

 

 

 

30

35

 

 

 

 

 

1

 

 

 

14

 

6

 

 

 

 

 

 

 

 

 

31

 

 

 

 

 

3

 

 

 

 

 

13

 

 

 

 

27

28 25

 

 

 

15 18

 

 

 

 

 

29

 

 

 

33

19

 

 

 

16,17

26

 

 

 

20

 

 

 

12

 

 

 

Location

Part

Description

No.

No.

 

 

 

 

01

43191634

Cabinet, Air Outled

02

43191636

Cabinet, Front, Ass’y

03

43191635

Cabinet, Side, Ass’y

04

43191637

Panel, Upper

05

43005489

Guard, Fin

06

43191630

Guard, Fan, PP-K

07

43122065

Bell Mouth, Plastic

08

43047667

Nut, Flange

09

43120123

Fan, Propeller, PJ491, AS-G

10

43121693

Motor, Fan, ICF-140-63-1

11

4314G117

Condenser, Ass’y

12

43191515

Panel, Front, Piping

13

43191605

Panel, Back, Piping

14

43119390

Hanger

15

43041772

Compressor Ass’y

16

43050407

Thermostat, Bimetal

17

43063317

Holder, Thermostat

18

43005482

Base Ass’y

19

43049739

Cushion, Rubber

Location

Part

No.

Description

No.

2043097204 Nut

2143046344 Valve, 4-WAY, CHV-0213

2243046348 Coil, Solenoid, VHV-01A150A1

2343046385 Valve, Pulse, Modulating, SKV-18D26

2443046386 Coil, PMV, DKV-MO25743BO

2543048066 Accumulator Ass’y

2643146584 Valve, Packed, 9.52DIA, HKT9.52

2743047401 Bonnet, 3/8 IN, 9.52 CU

2843146613 Valve, Ball, B5/8F

2943195029 Bonnet

3043148169 Strainer

3143148176 Strainer

3243058266 Reactor, CH-47-Z-K

3343063321 Holder, Sensor, 4-8, 9.52

3443063322 Holder, Sensor, 6-11.4, 12.7

3543063325 Holder, Sensor, 6-6.35, 8

3643063332 Holder, Sensor

3743032441 Nipple, Drain

– 83 –

Image 85
Contents AIR-CONDITIONER Contents Indoor Unit SpecificationsCurrent Operation characteristic curve Cooling HeatingRAV-SM560AT-E RAV-SM800AT-E Outdoor UnitConstruction Views Outdoor Unit RAV-SM560AT-E Outdoor Unit RAV-SM800AT-E RAV-SM560XT-E / RAV-SM560AT-E Systematic Refrigerating Cycle DiagramIndoor unit RAV-SM800XT-E / RAV-SM800AT-EColor Identification Wiring DiagramL N Board Parts name Type Specifications Specification of Electrical PartsRefrigerant Piping Installation Safety During Installation/ServicingRefrigerant R410A Piping materials and joints usedOuter diameter mm R410A R22 1 Thicknesses of annealed copper pipes Thickness mmProcessing of piping materials Width Clutch type Wing nut type·m kgf·m ·m kgf·cmRequired tools ToolsGeneral tools Conventional tools can be used Recharging of Refrigerant 1 Configuration of refrigerant chargingBrazing of Pipes Types of flux Noncorrosive flux Characteristics required for fluxActivated flux Filler FluxOperation Control Block DiagramOperation mode selection When power supply is resetAir volume control Operation Description1 Cold draft preventing control Cool air discharge preventive controlHigh-temp release control Freeze preventive control Low temperature releaseLouver control Filter sign displayAuto Restart Function How to set auto restart functionOperation MotionsPower failure during timer operation How to cancel auto restart functionHow to turn off filter check lamp Filter Check LampInstallation Diagram of Indoor and Outdoor Units Installation ProcedureUnder Ceiling Installation Console InstallationTo Disconnect the Appliance from Main Power Supply Precautions for SafetyPage Accessory parts Accessory parts and Parts to be procured locallyParts to be procured locally Avoid installing in the following places Selection of Installation PlaceRemote controller Installation PlaceRemote controller usage Before Installation Remove the Air inlet grilleInstall the Suspension bolts Install the indoor unitCondition for Installation Piping and Drain Hose InstallationConnect the Flexible pipe 5 to the large pipe Gas side Unit must not decline more than 15 mm in either Cutting a hole and mounting the Installation plateAxis Drainage Drain Piping WorkRefrigerant Piping Tightening connection Evacuating Heat insulation For RAV-SM560AT-E model Electrical Work Final Installation Checks LED indication and code checking Environment Summary of Troubleshooting TroubleshootingBefore troubleshooting Troubleshooting procedureHow to use remote control in service mode Self-Diagnosis by Remote Control Check CodeJudgement and action No display in the setting at shipment Operation YES Troubleshooting for Each Check Code 1A errorError 1C error* Except RAV-SM560AT-E 1E error 1D error1F error Connector normal? Caracteristics-3 TA sensor TC, TCJ sensor Caracteristics-1 Caracteristics-220 TE, TO, TS sensor TD sensor Caracteristics-4Compressor does not operate Inspection procedurePrimary check Cooling and heating model Are all of compressor cords normal? Detachments How to install the Air inlet grilleRemove the Panel arms from the Front panel Open 3 Cap screws and remove the screws How to remove the Drain pan Refrigeration How to remove the Refrigeration assembly Assembly Pan assemblyHow to remove the Multiblade fan Part name Procedures RemarksFan motor Detachment No. Part name Procedure RemarksProcedure Remarks Requirement Connection with the power terminal Part name Procedure Remarks ‡ Compressor Perform works of items 1 ‚, ƒ, „, … Fan guard Remove the upper cabinet Discharge port cabinet for the heat ex Part name Requirement… Control P.C Remove the inverter box from P.C. board base Loosen the flange nut by turning clock † Compressor Perform works of items , ‚, ƒ, „, Ø4 x 10L , 2 pcs. per one reactor Product Indoor Unit E-Parts Assy Exploded Views and Parts ListAir Inlet Grille Inverter 21,22 16,17 702 TE Sensor TS Sensor To Sensor TD Sensor 701 705 703 704 Outdoor Unit Inverter Assy, RAV-SM560AT-EOutdoor Unit Inverter Assy, RAV-SM800AT-E Inverter BOX