Toshiba RAV-SM560XT-E, RAV-SM800XT-E service manual Outdoor Unit RAV-SM560AT-E

Page 7

2-2. Outdoor Unit (RAV-SM560AT-E)

 

Drain hole (Ø25)

Drain hole (2-Ø20 x 88 long hole)

 

 

 

 

 

 

 

 

 

83

 

 

600

 

 

 

97

 

 

A legs

 

 

 

115.3

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

308

hole(Longpitch

anchorFor bolt)

302

holeØ6pitch

153

150

11

76

 

270

330

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

B legs

21

780

31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

521

49.5147

25

 

 

 

220

 

 

 

(49.3)

 

115.3

Discharge guide mounting hole

 

Discharge guard

 

(4-Ø4 embossing)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

center dividing)

 

 

 

 

21

593 598

 

 

 

31

 

 

(Fan500

 

 

 

23

 

 

 

 

 

 

 

 

 

 

 

 

90.6

132

 

 

500 (Fan center dividing)

Charge port 31

Protective net mounting hole

 

 

 

 

(2-Ø4 embossing)

 

 

 

 

216

134

Valve cover

Earth terminal

43

707

30

Protective net mounting hole

 

 

(4-Ø4 embossing)

 

60

 

 

475

Refrigerant pipe connecting port

(Ø12.7 flare at gas side) Refrigerant pipe connecting port (Ø6.4 flare at liquid side)

Space required for service

 

 

600

 

 

52

 

 

36

11

R15

2-Ø6 hole

308

302

Product

external line

 

 

 

Ø11 x 14 U-shape hole

Details of A legs

 

Ø11 x 14 U-

 

 

shape holes 2-Ø6 hole

308

302

Product

external

 

 

 

 

line

11

36

R15

 

 

52

 

 

 

600

Details of B legs

2-Ø11 x 14 U-shape holes

600

 

(For Ø8–Ø10 anchor bolt)

 

 

 

150 moreor

Suction port

 

 

 

 

 

 

 

300

 

 

 

or more

365

150

 

 

or more

Discharge (Minimum

 

 

port

distance up to wall)

 

500

Discharge

2-Ø11 x 14 long hole

 

or more

 

 

port

(For Ø8–Ø10 anchor bolt)

 

 

 

– 5 –

Image 7
Contents AIR-CONDITIONER Contents Indoor Unit SpecificationsCurrent Operation characteristic curve Cooling HeatingRAV-SM560AT-E RAV-SM800AT-E Outdoor UnitConstruction Views Outdoor Unit RAV-SM560AT-E Outdoor Unit RAV-SM800AT-E RAV-SM560XT-E / RAV-SM560AT-E Systematic Refrigerating Cycle DiagramIndoor unit RAV-SM800XT-E / RAV-SM800AT-EColor Identification Wiring DiagramL N Board Parts name Type Specifications Specification of Electrical PartsPiping materials and joints used Safety During Installation/ServicingRefrigerant Piping Installation Refrigerant R410AOuter diameter mm R410A R22 1 Thicknesses of annealed copper pipes Thickness mmProcessing of piping materials Width Clutch type Wing nut type·m kgf·m ·m kgf·cmRequired tools ToolsGeneral tools Conventional tools can be used Recharging of Refrigerant 1 Configuration of refrigerant chargingBrazing of Pipes Filler Flux Characteristics required for fluxTypes of flux Noncorrosive flux Activated fluxOperation Control Block DiagramOperation Description When power supply is resetOperation mode selection Air volume control1 Cold draft preventing control Cool air discharge preventive controlFilter sign display Freeze preventive control Low temperature releaseHigh-temp release control Louver controlMotions How to set auto restart functionAuto Restart Function OperationFilter Check Lamp How to cancel auto restart functionPower failure during timer operation How to turn off filter check lampConsole Installation Installation ProcedureInstallation Diagram of Indoor and Outdoor Units Under Ceiling InstallationTo Disconnect the Appliance from Main Power Supply Precautions for SafetyPage Accessory parts Accessory parts and Parts to be procured locallyParts to be procured locally Avoid installing in the following places Selection of Installation PlaceBefore Installation Remove the Air inlet grille Installation PlaceRemote controller Remote controller usagePiping and Drain Hose Installation Install the indoor unitInstall the Suspension bolts Condition for InstallationConnect the Flexible pipe 5 to the large pipe Gas side Unit must not decline more than 15 mm in either Cutting a hole and mounting the Installation plateAxis Drainage Drain Piping WorkRefrigerant Piping Tightening connection Evacuating Heat insulation For RAV-SM560AT-E model Electrical Work Final Installation Checks LED indication and code checking Environment Troubleshooting procedure TroubleshootingSummary of Troubleshooting Before troubleshootingHow to use remote control in service mode Self-Diagnosis by Remote Control Check CodeJudgement and action No display in the setting at shipment Operation YES Troubleshooting for Each Check Code 1A errorError 1C error* Except RAV-SM560AT-E 1E error 1D error1F error Connector normal? TD sensor Caracteristics-4 TA sensor TC, TCJ sensor Caracteristics-1 Caracteristics-2Caracteristics-3 20 TE, TO, TS sensorCompressor does not operate Inspection procedurePrimary check Cooling and heating model Are all of compressor cords normal? Detachments How to install the Air inlet grilleRemove the Panel arms from the Front panel Open 3 Cap screws and remove the screws How to remove the Drain pan Refrigeration How to remove the Refrigeration assembly Assembly Pan assemblyHow to remove the Multiblade fan Part name Procedures RemarksFan motor Detachment No. Part name Procedure RemarksProcedure Remarks Requirement Connection with the power terminal Part name Procedure Remarks ‡ Compressor Perform works of items 1 ‚, ƒ, „, … Fan guard Remove the upper cabinet Discharge port cabinet for the heat ex Part name Requirement… Control P.C Remove the inverter box from P.C. board base Loosen the flange nut by turning clock † Compressor Perform works of items , ‚, ƒ, „, Ø4 x 10L , 2 pcs. per one reactor Product Indoor Unit E-Parts Assy Exploded Views and Parts ListAir Inlet Grille Inverter 21,22 16,17 702 TE Sensor TS Sensor To Sensor TD Sensor 701 705 703 704 Outdoor Unit Inverter Assy, RAV-SM560AT-EOutdoor Unit Inverter Assy, RAV-SM800AT-E Inverter BOX