12-2. Indoor Unit

 

 

 

222

220

 

 

 

 

 

 

 

 

217

 

 

 

 

 

218

224

 

227

 

 

 

 

 

 

 

 

 

 

208

214

 

 

 

 

 

 

 

 

 

 

207

 

 

223

 

 

 

 

 

 

 

208

 

 

 

203

 

212

 

 

216

 

235

 

 

 

 

206

 

 

 

219

 

 

 

 

 

 

 

204

 

 

 

 

202

 

 

 

221

225

 

 

 

 

 

 

 

213

 

 

226

 

 

 

 

 

 

 

210

211

 

229

 

 

 

 

 

 

 

 

 

 

 

209

215

233

228

 

 

 

 

 

 

 

 

231

 

235

 

234

201

205

 

 

 

 

230

 

 

232

 

 

 

Location

Part

Description

No.

No.

 

 

 

 

201

43T09312

Air Inlet Grille

202

43T00357

Panel Arm Assy

203

43T00358

Front Panel Assy

204

43T01004

Mark

205

43T79303

Drain Band

206

43T80302

Air Filter

207

43T00359

Cap Screw C

208

43T00360

Cap Screw LR

209

43T20303

Fan Cover

210

43T20304

Motor Band Assy

211

43T20305

Multiblade Fan

212

43T19309

Screw Set (D-T)

213

43T21325

Fan Motor

214

43T72301

Drain Pan Assy

215

43T79304

Drain Hose Assy

216

43T19303

Louver Motor Assy

217

43T09313

Horizontal Louver

218

43T44331

Refrigeration Assy, 12.7

 

 

(SM560XT-E)

218

43T44332

Refrigeration Assy, 15.9

 

 

(SM800XT-E)

 

 

 

Location

Part

Description

No.

No.

 

 

 

 

219

43T03303

Back Body Assy

220

43T09314

Vertical Louver

221

43T49303

Pipe Holder

222

43T19304

Cover Body L

223

43T19305

Cover Body R

224

43T19306

Cover Body LD

225

43T19307

Bush Body R

226

43T19308

Bush Body D

227

43T82302

Installation Plate

228

43T60314

Terminal Cover

229

43T62303

Connector Cover

230

43T83003

Remote control Holder

231

43T69309

Wireless Remote control

232

43T85399

Owner’s Manual

233

43T49304

Flexible pipe, 12.7 Assy

 

 

(SM560XT-E)

233

43T49310

Flexible pipe, 15.9 Assy

 

 

(SM800XT-E)

234

43T80003

Filter Frame

235

43T00365

Grille Stopper Assy

 

 

 

– 81 –

Image 83
Contents AIR-CONDITIONER Contents Indoor Unit SpecificationsCurrent Operation characteristic curve Cooling HeatingRAV-SM560AT-E RAV-SM800AT-E Outdoor UnitConstruction Views Outdoor Unit RAV-SM560AT-E Outdoor Unit RAV-SM800AT-E RAV-SM560XT-E / RAV-SM560AT-E Systematic Refrigerating Cycle DiagramIndoor unit RAV-SM800XT-E / RAV-SM800AT-EColor Identification Wiring DiagramL N Board Parts name Type Specifications Specification of Electrical PartsPiping materials and joints used Safety During Installation/ServicingRefrigerant Piping Installation Refrigerant R410AProcessing of piping materials 1 Thicknesses of annealed copper pipes Thickness mmOuter diameter mm R410A R22 Width Clutch type Wing nut type·m kgf·m ·m kgf·cmGeneral tools Conventional tools can be used ToolsRequired tools Recharging of Refrigerant 1 Configuration of refrigerant chargingBrazing of Pipes Filler Flux Characteristics required for fluxTypes of flux Noncorrosive flux Activated fluxOperation Control Block DiagramOperation Description When power supply is resetOperation mode selection Air volume control1 Cold draft preventing control Cool air discharge preventive controlFilter sign display Freeze preventive control Low temperature releaseHigh-temp release control Louver controlMotions How to set auto restart functionAuto Restart Function OperationFilter Check Lamp How to cancel auto restart functionPower failure during timer operation How to turn off filter check lampConsole Installation Installation ProcedureInstallation Diagram of Indoor and Outdoor Units Under Ceiling InstallationTo Disconnect the Appliance from Main Power Supply Precautions for SafetyPage Parts to be procured locally Accessory parts and Parts to be procured locallyAccessory parts Avoid installing in the following places Selection of Installation PlaceBefore Installation Remove the Air inlet grille Installation PlaceRemote controller Remote controller usagePiping and Drain Hose Installation Install the indoor unitInstall the Suspension bolts Condition for InstallationConnect the Flexible pipe 5 to the large pipe Gas side Axis Cutting a hole and mounting the Installation plateUnit must not decline more than 15 mm in either Drainage Drain Piping WorkRefrigerant Piping Tightening connection Evacuating Heat insulation For RAV-SM560AT-E model Electrical Work Final Installation Checks LED indication and code checking Environment Troubleshooting procedure TroubleshootingSummary of Troubleshooting Before troubleshootingHow to use remote control in service mode Self-Diagnosis by Remote Control Check CodeJudgement and action No display in the setting at shipment Operation YES Troubleshooting for Each Check Code 1A errorError 1C error* Except RAV-SM560AT-E 1F error 1D error1E error Connector normal? TD sensor Caracteristics-4 TA sensor TC, TCJ sensor Caracteristics-1 Caracteristics-2Caracteristics-3 20 TE, TO, TS sensorPrimary check Inspection procedureCompressor does not operate Cooling and heating model Are all of compressor cords normal? Remove the Panel arms from the Front panel How to install the Air inlet grilleDetachments Open 3 Cap screws and remove the screws How to remove the Drain pan Refrigeration How to remove the Refrigeration assembly Assembly Pan assemblyFan motor Part name Procedures RemarksHow to remove the Multiblade fan Detachment No. Part name Procedure RemarksProcedure Remarks Requirement Connection with the power terminal Part name Procedure Remarks ‡ Compressor Perform works of items 1 ‚, ƒ, „, … Fan guard Remove the upper cabinet Discharge port cabinet for the heat ex Part name Requirement… Control P.C Remove the inverter box from P.C. board base Loosen the flange nut by turning clock † Compressor Perform works of items , ‚, ƒ, „, Ø4 x 10L , 2 pcs. per one reactor Product Indoor Unit E-Parts Assy Exploded Views and Parts ListAir Inlet Grille Inverter 21,22 16,17 702 TE Sensor TS Sensor To Sensor TD Sensor 701 705 703 704 Outdoor Unit Inverter Assy, RAV-SM560AT-EOutdoor Unit Inverter Assy, RAV-SM800AT-E Inverter BOX