GE Zoneline 6100 Series Air Conditioner Manual and Specifications

Page 2

Quick Reference

Full Specs on pages 52 and 53

ALL UNITS REQUIRE POWER CONNECTION KIT

Power Connection Kit determines resistance heat output 7000 Btuh units are not offered with 4.7 KW resistance heater

4100 Series Cooling with Electric Heat

MODEL

COOLING

EER

NUMBER

(Btuh)

 

AZ41E07DA*

7300/7100

12.8/12.8

AZ41E09DA*

9450/9250

12.3/12.3

AZ41E12DA*

11800/11600

11.8/11.8

AZ41E15DA*

14700/14500

10.6/10.6

AZ41E07EA*

7300

12.8

AZ41E09EA*

9450

12.3

AZ41E12EA*

11800

11.8

AZ41E15EA*

14700

10.6

Dry Air 25

4100 Series Cooling with Electric Heat

MODEL

COOLING

EER

NUMBER

(Btuh)

 

AZ41E07DAP

6800/6600

12.2/12.2

AZ41E09DAP

9000/8800

11.8/11.8

AZ41E12DAP

11200/11000

11.3/11.3

AZ41E07EAP

6800

12.2

AZ41E09EAP

9000

11.8

AZ41E12EAP

11200

11.3

6100 Series Heat Pump with Backup Electric Heat

MODEL

COOLING

EER

Reverse Cycle

COP

NUMBER

(Btuh)

BTUH

 

 

 

 

 

 

 

AZ61H07DA*

7200/7000

13.2/13.2

6400/6200

4.0/4.0

AZ61H09DA*

9400/9200

12.7/12.7

8300/8100

3.8/3.8

AZ61H12DA*

11800/11600

12.1/12.1

10600/10400

3.7/3.7

AZ61H15DA*

14800/14600

11.2/11.2

14000/13900

3.3/3.3

AZ61H07EA*

7200

13.2

6400

4.0

AZ61H09EA*

9400

12.7

8300

3.8

AZ61H12EA*

11800

12.1

10600

3.7

AZ61H15EA*

14800

11.2

14000

3.3

4100 and 6100 Series Control Panel

*Dual-rated 230/208-volt units are shown with ratings separated by “/”. Units with single rating are 265-volt units.

2

Image 2
Contents GE Zoneline packaged terminal air conditioners Quick Reference 6100 Series Control Panel230/208-Volt Line Cord Connection Units Power Connection KitsZoneline Chassis Nomenclature Volt Sub-Base and Direct Connected UnitsDeluxe Dry Air 25 Models Cooling With Resistance HeatTable of Contents Introduction Deluxe Line Standard FeaturesDeluxe Line Optional Features Advantages of the GE Zoneline SystemOptional Accessories of the Zoneline System Zoneline SystemZoneline Features Resistance heatFeatures and Benefits Compressor Restart Delay Fan-Only Setting HIGH/LOWFan-Cycle Switch SmartFan Electronic Temperature LimitingCorrosion Protection Optional Up-Front Air FiltersConcealed Manual Vent Control Internal Condensate Removal ICRTo change modes Auxiliary Control SettingsAuxiliary Control-Aux Set Button Press AUX SET AU appears on the displayTemperature limits-Cool Important CDC Comments all series applicable CDC Terminal Location and Typical WiringCentral Desk Control Resistance Heat Models Field Wiring TerminalRemote Thermostat Control RAK806 Universal Control Cover LabelRAK148D1 RAK148P1 Feature Heat Pump Electric HeatHeat Pump Models Low-Voltage Conductors Zoneline SeriesType Function For remote thermostat operation follow the steps belowHeat Pumps and Energy Savings Balance PointHeat pump defrost Zoneline 6100 Series Heat Pump Operation Zoneline 6100 SeriesZoneline Heat Pump Heat Source Logic Heat pump condensateHigh Wall Mount For units Application CommentsAir Distribution 16-1/4 MIN. x 42-1/4 MIN DimensionsAdditional 16-1/2 MIN. x 42-3/8 MINSub-Base RAK204U No receptacle, no wiring will accept anyWall Case Choice of wall cases is available for Zoneline unitsSub-bases for the 265-volt units Wall Case Installation DataGeneral Masonry Wall Construction Architectural Window Louver InstallationWindow, Curtain and Panel Wall Construction Brick, Frame, Stucco Shingle ConstructionCase Angles Installation of Wall Case in Wall OpeningPreparation of the Wall Case for All Types of Construction Framing for Wall Case Brick Veneer and Frame ConstructionFrame and Brick Veneer Installation Cord set connected Wall Section Detailed Side ViewWall Case Receptacle Wall Case Installation Cord SET Connected AS Reqd Geappliances.com TOP View RAK204 Series SUB-BASE Installation and Electrical Data RAB71A/77 Wall CaseCondensate Disposal Systems Wall Case with RAD10 Drain KIT External Drain. See page 36 for internal drainInternal Drain. See page 35 for external drain Replacements of Existing Ducted Units Ducted InstallationsNew Ducted Installations Ducted Application ConsiderationsDuct Adapter Extension has 1/2 Insulation Com RAG63 Bittersweet Chocolate Exterior GrillesOutdoor Grille Exterior Architectural Treatments Special Outdoor Grilles 230/208-Volt Permanently Connected Units Or 277-Volt Unit Installation Permanently Connected Units230/208-Volt Line-Cord Connected Units 230/208 Volt Sub-Base and Direct-Connected UnitsEssential Elements Ordering Overview Electrical Wiring Information 4100/6100 SeriesReplacement of Existing Chassis Volt Units Maximum Connected LoadLatent System Capacity Formula for Calculating Operating Costs Using Above Data Normal Yearly Operating DataTypical 4100 Series, 230/208-Volt Wiring Diagram Typical 4100 Series, 230/208-Volt Schematic Diagram Typical 6100 Series, 230/208-Volt Wiring Diagram Typical 6100 Series, 230/208-Volt Schematic Diagram Suggested Bid Form Specifications Each shall consist of the following sections and componentsAlternate specification for molded wall case Receptacles/Sub-Bases 6 1 H 1 2 D a DPreliminary Specifications CapacityComplete Accessory List Kit Number DescriptionGeneral Installation Suggestions Replacement Installations Zoneline WarrantyDucted Installation Comments New InstallationsGeappliances.com Page Category Alphabetical IndexExterior Grille Color Samples Beige Maple BittersweetYears of innovation and we’re just getting started