Preliminary Specifications

 

Deluxe series – cooling & electric heat

 

 

Dry Air 25

 

 

 

 

4100 series units

 

 

Dry Air 25

 

230/208V Models

AZ41E07D

AZ41E09D

 

AZ41E12D

AZ41E15D

AZ41E07DAP

AZ41E09DAP

AZ41E12DAP

Capacity

 

 

 

 

 

 

 

 

Cooling BTUH

7,300/7,100

9,450/9,250

 

11,800/11,600

14,700/14,500

6,800/6,600

9,000/8,800

11,200/11,000

EER (BTU/Watt)

12.8/12.8

12.3/12.3

 

11.8/11.8

10.6/10.6

12.2/12.2

11.8/11.8

11.3/11.3

Dehumidification Pts/Hr

1.7

2.7

 

3.5

4.6

2.3

3.4

4.4

Features

 

 

 

 

 

 

 

 

Refrigerant type

R-410A

R-410A

 

R-410A

R-410A

R-410A

R-410A

R-410A

CFM, indoor fan high

290

340

 

420

409

220

280

330

CFM, indoor fan low

218

229

 

323

324

190

208

270

Vent CFM (full open/partial open)

50/40

70/45

 

75/45

75/45

50/40

70/45

75/45

Power/Ratings

 

 

 

 

 

 

 

 

Power factor

89%

93%

 

93%

90%/92%

86%/87%

92%

92%

Sensible heat ratio @ 230 volts

80%

75%

 

70%

70%

60%

60%

60%

Watts

570/555

770/755

 

1000/985

1390/1370

555/540

765/745

995/975

Cooling Amperes, F.L.

2.8/3.0

3.6/3.9

 

4.7/5.1

6.7/7.2

2.8/3.0

3.6/3.9

4.7/5.1

Amperes, L.R.

19.0

21.0

 

29.5

31.0

19.0

21.0

29.5

Weight (Net/Ship)

89.5/102.5

99.9/112.9

 

99.4/112.4

100.3/113.3

97.0/110.0

105.2/118.2

105.4/118.4

 

 

 

 

 

 

 

 

 

265V Models

AZ41E07E

AZ41E09E

 

AZ41E12E

AZ41E15E

AZ41E07EAP

AZ41E09EAP

AZ41E12EAP

Capacity

 

 

 

 

 

 

 

 

Cooling BTUH

7,300

9,450

 

11,800

14,700

6,800

9,000

11,200

EER (BTU/Watt)

12.8

12.3

 

11.8

10.6

12.2

11.8

11.3

Dehumidification Pts/Hr

1.7

2.7

 

3.5

4.6

2.3

3.4

4.4

Features

 

 

 

 

 

 

 

 

CFM, indoor fan high

290

340

 

420

406

220

280

330

CFM, indoor fan low

215

229

 

323

324

190

208

270

Vent CFM (full open/partial open)

50/40

70/45

 

75/45

75/45

50/40

70/45

75/45

Power/Ratings

 

 

 

 

 

 

 

 

Power factor

90%

91%

 

92%

92%

87%

90%

92%

Sensible heat ratio @ 265 volts

80%

75%

 

70%

70%

60%

60%

60%

Watts

570

770

 

1000

1390

555

765

995

Cooling Amperes, F.L.

2.4

3.2

 

4.1

5.7

2.4

3.2

4.1

Amperes, L.R.

12.0

16.5

 

23.5

26.0

12.0

16.5

23.5

Weight (Net/Ship)

91.3/104.3

101.2/114.2

 

99.9/112.9

101.0/114.0

97.4/110.5

104.9/117.9

108.0/121.0

 

 

Deluxe series – heat pump units**

 

 

 

 

 

6100 series units

 

230/208V Models

 

AZ61H07D

AZ61H09D

AZ61H12D

AZ61H15D

Capacity

 

 

 

 

 

Cooling BTUH

 

7,200/7,000

9,400/9,200

11,800/11,600

14,800/14,600

EER (BTU/Watt)

 

13.2/13.2

12.7/12.7

12.1/12.1

11.2/11.2

Dehumidification Pts/Hr

 

1.7

2.7

3.5

4.5

Features

 

 

 

 

 

Refrigerant type

 

R-410A

R-410A

R-410A

R-410A

CFM, indoor fan high

 

340

360

370

370

CFM, indoor fan low

 

194

212

284

290

Vent CFM (full open/partial open)

 

50/40

70/45

75/45

75/45

Power/Ratings

 

 

 

 

 

Power factor

 

91%

92%

92%

91%/92%

Sensible heat ratio @ 230 volts

 

85%

75%

70%

65%

Cooling Watts

 

545/530

740/725

975/960

1,325/1,305

Cooling Amperes, F.L.

 

2.6/2.8

3.5/3.8

4.6/5.0

6.3/6.8

Amperes, L.R.

 

19.0

21.0

29.5

31.0

Reverse cycle heat BTUH

 

6,400/6,200

8,300/8,100

10,600/10,400

14,000/13,900

COP

 

4.0/4.0

3.8/3.8

3.7/3.7

3.3/3.3

Heating Watts

 

470/455

645/630

850/835

1,245/1,235

Heating Amperes

 

2.2/2.4

3.1/3.3

4.1/4.5

5.8/6.3

Weight (Net/Ship)

 

94.1/107.1

101.4/114.4

102.1/115.1

100.8/113.8

 

 

 

 

 

265V Models

 

AZ61H07E

AZ61H09E

AZ61H12E

AZ61H15E

Capacity

 

 

 

 

 

Cooling BTUH

 

7,200

9,400

11,800

14,800

EER (BTU/Watt)

 

13.2

12.7

12.1

11.2

Dehumidification Pts/Hr

 

1.7

2.7

3.5

4.5

Features

 

 

 

 

 

Refrigerant type

 

R-410A

R-410A

R-410A

R-410A

CFM, indoor fan high

 

340

360

370

370

CFM, indoor fan low

 

194

211

284

290

Vent CFM (full open/partial open)

 

50/40

70/45

75/45

75/45

Power/Ratings

 

 

 

 

 

Power factor

 

94%

90%

92%

93%

Sensible heat ratio @ 265 volts

 

85%

75%

70%

65%

Cooling Watts

 

545

740

975

1,325

Cooling Amperes, F.L.

 

2.2

3.1

4.0

5.4

Amperes, L.R.

 

12.0

16.5

23.5

26.0

Reverse cycle heat BTUH

 

6,400

8,300

10,600

14,000

COP

 

4.0

3.8

3.7

3.3

Heating Watts

 

470

645

850

1,245

Heating Amperes

 

2.0

2.7

3.6

5.0

Weight (Net/Ship)*

 

94.6/107.6

103.6/116.6

103.6/116.6

104.3/117.3

**ICR adds 3 pounds to unit weight

 

 

 

 

**Corrosion model BTUH and watts may vary.

 

 

 

 

Preliminary specifications subject to change.

53

Image 53
Contents GE Zoneline packaged terminal air conditioners 6100 Series Control Panel Quick ReferenceZoneline Chassis Nomenclature Power Connection Kits230/208-Volt Line Cord Connection Units Volt Sub-Base and Direct Connected UnitsCooling With Resistance Heat Deluxe Dry Air 25 ModelsTable of Contents Deluxe Line Optional Features Deluxe Line Standard FeaturesIntroduction Advantages of the GE Zoneline SystemZoneline System Optional Accessories of the Zoneline SystemResistance heat Zoneline FeaturesFeatures and Benefits Fan-Cycle Switch SmartFan Fan-Only Setting HIGH/LOWCompressor Restart Delay Electronic Temperature LimitingConcealed Manual Vent Control Up-Front Air FiltersCorrosion Protection Optional Internal Condensate Removal ICRAuxiliary Control-Aux Set Button Auxiliary Control SettingsTo change modes Press AUX SET AU appears on the displayTemperature limits-Cool Important CDC Comments all series applicable CDC Terminal Location and Typical WiringCentral Desk Control Remote Thermostat Control Field Wiring TerminalResistance Heat Models RAK806 Universal Control Cover LabelRAK148D1 RAK148P1 Feature Heat Pump Electric HeatHeat Pump Models Type Function Zoneline SeriesLow-Voltage Conductors For remote thermostat operation follow the steps belowBalance Point Heat Pumps and Energy SavingsZoneline Heat Pump Heat Source Logic Heat Pump Operation Zoneline 6100 SeriesHeat pump defrost Zoneline 6100 Series Heat pump condensateHigh Wall Mount For units Application CommentsAir Distribution Additional Dimensions16-1/4 MIN. x 42-1/4 MIN 16-1/2 MIN. x 42-3/8 MINWall Case RAK204U No receptacle, no wiring will accept anySub-Base Choice of wall cases is available for Zoneline unitsSub-bases for the 265-volt units Wall Case Installation DataGeneral Window, Curtain and Panel Wall Construction Architectural Window Louver InstallationMasonry Wall Construction Brick, Frame, Stucco Shingle ConstructionCase Angles Installation of Wall Case in Wall OpeningPreparation of the Wall Case for All Types of Construction Brick Veneer and Frame Construction Framing for Wall CaseWall Section Detailed Side View Frame and Brick Veneer Installation Cord set connectedWall Case Receptacle Wall Case Installation Cord SET Connected AS Reqd Geappliances.com TOP View RAB71A/77 Wall Case RAK204 Series SUB-BASE Installation and Electrical DataCondensate Disposal Systems External Drain. See page 36 for internal drain Wall Case with RAD10 Drain KITInternal Drain. See page 35 for external drain New Ducted Installations Ducted InstallationsReplacements of Existing Ducted Units Ducted Application ConsiderationsDuct Adapter Extension has 1/2 Insulation Com RAG63 Bittersweet Chocolate Exterior GrillesOutdoor Grille Exterior Architectural Treatments Special Outdoor Grilles 230/208-Volt Line-Cord Connected Units Or 277-Volt Unit Installation Permanently Connected Units230/208-Volt Permanently Connected Units 230/208 Volt Sub-Base and Direct-Connected UnitsEssential Elements Ordering Overview Electrical Wiring Information 4100/6100 SeriesReplacement of Existing Chassis Volt Units Maximum Connected LoadLatent System Capacity Normal Yearly Operating Data Formula for Calculating Operating Costs Using Above DataTypical 4100 Series, 230/208-Volt Wiring Diagram Typical 4100 Series, 230/208-Volt Schematic Diagram Typical 6100 Series, 230/208-Volt Wiring Diagram Typical 6100 Series, 230/208-Volt Schematic Diagram Each shall consist of the following sections and components Suggested Bid Form SpecificationsAlternate specification for molded wall case 6 1 H 1 2 D a D Receptacles/Sub-BasesCapacity Preliminary SpecificationsKit Number Description Complete Accessory ListGeneral Installation Suggestions Ducted Installation Comments Zoneline WarrantyReplacement Installations New InstallationsGeappliances.com Page Exterior Grille Color Samples Alphabetical IndexCategory Beige Maple BittersweetYears of innovation and we’re just getting started