TROUBLESHOOTING

TROUBLESHOOTING

OBSERVED FAULT WARNING: Never service heater while it is plugged in, connected to propane supply, operating, or hot. Severe burns and electrical shock can occur.

OBSERVED FAULT

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

Fan does not turn when heater is

1.

No electrical power to heater

1.

Check voltage to electrical

plugged in

 

 

 

outlet. If voltage is good,

 

 

 

 

check heater power cord for

 

 

 

 

breaks

 

2.

Fan hitting inside of heater

2.

Adjust motor/fan guard to

 

 

shell

 

keep fan from hitting inside of

 

 

 

 

heater shell. Bend fan guard if

 

 

 

 

necessary

 

3.

Fan blades bent

3.

Replace fan. See Fan, page 8

 

4.

Defective motor

4.

Replace motor. See Motor,

 

 

 

 

page 7

 

 

 

 

 

Heater will not ignite

1.

User did not follow installa-

1.

Repeat installation and opera-

 

 

tion or operation instructions

 

tion instructions. See Installa-

 

 

properly

 

tion and Operation, page 5

 

2.

No spark at ignitor. To test for

2.

A) Check ignitor wire. Tighten

 

 

spark, follow step 9 under Ig-

 

or reattach loose ignitor wire.

 

 

nitor, page 8. If you see spark

 

See Figure 14, page 8 for

 

 

at ignitor, have heater serviced

 

ignitor wire location

 

 

by qualified service person. If

 

B) Set gap between ignitor

 

 

no spark seen:

 

electrode and target plate to

 

 

A) Loose or disconnected

 

0.17" (4.3 mm)

 

 

ignitor wire

 

C) Tighten nut holding piezo

 

 

B) Wrong spark gap

 

ignitor to base of heater

 

 

C) Piezo ignitor loose

 

D) Replace ignitor electrode.

 

 

D) Bad ignitor electrode

 

See Ignitor, page 8

 

 

 

 

 

Heater shuts down while run-

1.

High surrounding air tem-

1.

This can happen when running

ning

 

perature causing thermal limit

 

heater in temperatures above

 

 

device to shut down heater

 

85° F (29° C). Run heater in

 

2.

Restricted air flow

 

cooler temperatures

 

2.

Check heater inlet and outlet.

 

3.

Damaged fan

 

Remove any obstructions

 

3.

Replace fan. See Fan, page 8

 

4.

Excessive dust or debris in

4.

Clean heater. See Mainte-

 

 

surrounding area

 

nance, page 6

POSSIBLE CAUSE WARNING:Useonlyinareas free of high dust content.

105339-01C

www.desatech.com

9

Image 9
Contents GENERAL HAZARD WARNING WARNING Not for home or recreational vehicle use SAFETY INFORMATIONUNPACKING SAFETY INFORMATIONPRODUCT IDENTIFICATION PROPANE SUPPLYASSEMBLY THEORY OF OPERATIONVENTILATION OPERATION INSTALLATIONMAINTENANCE OPERATIONSTORAGE SERVICE PROCEDURES MAINTENANCEContinued ELECTRICAL SYSTEMFigure 14 - Removing Ignitor Wire from SERVICE PROCEDURESContinued IGNITOROBSERVED FAULT TROUBLESHOOTINGPOSSIBLE CAUSE REMEDYMODELS RCLP50VA AND 50-F ILLUSTRATED PARTS BREAKDOWN1 2 3 2 2 19 21 22 24 29 4MODELS RCLP50VA AND 50-F PARTS LISTTECHNICAL SERVICE SPECIFICATIONSREPLACEMENT PARTS ACCESSORY105339-01C KEEP THIS WARRANTY WARRANTY AND REPAIR SERVICELIMITED WARRANTY WARRANTY SERVICETABLA DE CONTENIDO ADVERTENCIA GENERAL DE PELIGROINFORMACIÓN DE SEGURIDAD IDENTIFICACIÓN DEL PRODUCTO DESEMPAQUESUMINISTRO DE PROPANO ContinuaciónVENTILACIÓN TEORÍA DE FUNCIONAMIENTOENSAMBLAJE tener un espacio abierto al aireINSTALACIÓN FUNCIONAMIENTOPARA ENCENDER EL CALENTADOR ALMACENAMIENTO FUNCIONAMIENTOMANTENIMIENTO ContinuaciónPROCEDIMIENTOS DE SERVICIO MANTENIMIENTOContinuación SISTEMA ELÉCTRICOSERVICIO Continuación PROCEDIMIENTOS DEVENTILADOR ENCENDEDORFALLA OBSERVADA SOLUCIÓN DE PROBLEMASCAUSA POSIBLE REMEDIOMODELOS RCLP50VA Y 50-F CLASIFICACIÓN ILUSTRADA DE PIEZAS1 2 3 2 2 19 29 4 16 20LISTA DE PIEZAS MODELOS RCLP50VA Y 50-FCámara de combustión SERVICIO TÉCNICO ESPECIFICACIONESPIEZAS DE REPUESTO ACCESORIOSNOTAS GUARDE ESTA GARANTÍA GARANTÍA Y SERVICIO DE REPARACIÓNGARANTÍA LIMITADA SERVICIO DE GARANTÍATABLE DES MATIÈRES AVERTISSEMENT DE RISQUE GÉNÉRALINFORMATION RELATIVE À LA SÉCURITÉ DÉBALLAGE INFORMATION RELATIVE ÀLA SÉCURITÉ SuiteIDENTIFICATION DU PRODUIT Figure 1 - Modèle à 50 000 BTU/hTHÉORIE DE FONCTIONNEMENT APPROVISIONNEMENT EN PROPANEVENTILATION ASSEMBLAGEASSEMBLAGE INSTALLATIONSuite Figure 3 - Retrait de la vis sur le dessusFONCTIONNEMENT INSTALLATIONSuite POUR ALLUMER LAPPAREIL DE CHAUFFAGEFONCTIONNEMENT ENTREPOSAGEENTRETIEN Figure 12 - Retrait ou installation de la Figure 11 - Emplacement de la vis darrêtPROCÉDURES DENTRETIEN CIRCUIT ÉLECTRIQUEVENTILATEUR SuiteALLUMEUR Figure 14 - Retrait du fil de lallumeur deDÉPANNAGE SOLUTIONPROBLÈME OBSERVÉ CAUSE POSSIBLEACCESSOIRE SERVICE TECHNIQUESPÉCIFICATIONS PIÈCES DE RECHANGEMODÈLES RCLP50VA ET 50-F VUE DÉTAILLÉE DES PIÈCES1 2 3 2 2 19 21 29 4MODÈLES RCLP50VA ET 50-F LISTE DES PIÈCESPage 105339-01C SERVICE DE RÉPARATION SERVICE DE GARANTIE ET DE RÉPARATIONCONSERVEZ CETTE GARANTIE GARANTIE LIMITÉE