Desa RCLP50-F Service Procedures, Continued, Removing Ignitor Wire from, Piezo Ignitor

Page 8
IGNITOR

SERVICE PROCEDURES

Continued

FAN

1.Remove three screws that attach fan guard to heater shell.

2.Remove motor and fan guard from heater shell (see Figure 10, page 7).

3.Use hex wrench to loosen set screw that holds fan to motor shaft (see Figure 11, page 7).

4.Remove fan. Be careful not to damage the fan blade pitch.

5a. If replacing fan, remove old fan and discard. Go to step 7 below.

5b. If cleaning fan, use soft cloth moistened with kerosene or solvent.

6.Dry fan thoroughly.

7.Place fan onto motor shaft of new motor. Make sure set screw contacts flat surface on motor shaft. Tighten set screw firmly (40-50 inch-pounds).

8.Place motor and fan guard into rear of heater shell. Make sure power cord is properly lo- cated (see Figure 13, page 7).

9.Insert three screws through heater shell and into fan guard. Tighten screws firmly.

IGNITOR

1.Remove motor and fan guard from heater (see Motor, page 7, steps 1 through 5).

2.Remove black ignitor wire from piezo ignitor. Access ignitor wire through underside of heater base (see Figure 14). Push wire up through bushing in heater shell.

3.Remove ignitor mounting screw from rear head using nut-driver or standard screwdriver (see Figure 15).

4.Remove ignitor from rear head.

5.Install new ignitor. Attach ignitor to rear head with ignitor mounting screw.

6.Run ignitor wire from new ignitor through bushing in heater shell. Attach ignitor wire to piezo ignitor.

7.Set gap between ignitor electrode and target plate to 0.17" (4.3 mm) (see Figure 16).

Figure 14 - Removing Ignitor Wire from WARNING: Make sure heater is disconnected from propane supply. Heater could ignite caus- ing severe burns.

8.Test for spark. Push piezo ignitor button and watch for spark between ignitor electrode and target plate.

9.Place motor and fan guard into rear of heater shell (see Motor, page 7, steps 9 and 10).

Piezo

Ignitor

Ignitor Wire

Piezo Ignitor Bushing

Figure 15 - Removing Ignitor MountingUnderside of

Heater Base

Figure 14 - Removing Ignitor Wire from

Piezo Ignitor

Rear

Head Screw and Ignitor

Ignitor

Ignitor

 

Mounting

 

Screw

 

Figure 15 - Removing Ignitor Mounting
Screw and Ignitor

Target Plate

Ignitor

 

Electrode

Figure 16 - Clearance between IgnitorGap

Area

Figure 16 - Clearance between Ignitor
Electrode and Target Plate

8

www.desatech.com

105339-01C

Image 8
Contents GENERAL HAZARD WARNING SAFETY INFORMATION WARNING Not for home or recreational vehicle useSAFETY INFORMATION UNPACKINGPRODUCT IDENTIFICATION PROPANE SUPPLYVENTILATION ASSEMBLYTHEORY OF OPERATION INSTALLATION OPERATIONSTORAGE MAINTENANCEOPERATION MAINTENANCE SERVICE PROCEDURESContinued ELECTRICAL SYSTEMSERVICE PROCEDURES Figure 14 - Removing Ignitor Wire fromContinued IGNITORTROUBLESHOOTING OBSERVED FAULTPOSSIBLE CAUSE REMEDYILLUSTRATED PARTS BREAKDOWN MODELS RCLP50VA AND 50-F1 2 3 2 2 19 21 22 24 29 4PARTS LIST MODELS RCLP50VA AND 50-FSPECIFICATIONS TECHNICAL SERVICEREPLACEMENT PARTS ACCESSORY105339-01C WARRANTY AND REPAIR SERVICE KEEP THIS WARRANTYLIMITED WARRANTY WARRANTY SERVICEADVERTENCIA GENERAL DE PELIGRO TABLA DE CONTENIDOINFORMACIÓN DE SEGURIDAD DESEMPAQUE IDENTIFICACIÓN DEL PRODUCTOSUMINISTRO DE PROPANO ContinuaciónTEORÍA DE FUNCIONAMIENTO VENTILACIÓNENSAMBLAJE tener un espacio abierto al airePARA ENCENDER EL CALENTADOR INSTALACIÓNFUNCIONAMIENTO FUNCIONAMIENTO ALMACENAMIENTOMANTENIMIENTO ContinuaciónMANTENIMIENTO PROCEDIMIENTOS DE SERVICIOContinuación SISTEMA ELÉCTRICOPROCEDIMIENTOS DE SERVICIO ContinuaciónVENTILADOR ENCENDEDORSOLUCIÓN DE PROBLEMAS FALLA OBSERVADACAUSA POSIBLE REMEDIOCLASIFICACIÓN ILUSTRADA DE PIEZAS MODELOS RCLP50VA Y 50-F1 2 3 2 2 19 29 4 16 20Cámara de combustión LISTA DE PIEZASMODELOS RCLP50VA Y 50-F ESPECIFICACIONES SERVICIO TÉCNICOPIEZAS DE REPUESTO ACCESORIOSNOTAS GARANTÍA Y SERVICIO DE REPARACIÓN GUARDE ESTA GARANTÍAGARANTÍA LIMITADA SERVICIO DE GARANTÍAAVERTISSEMENT DE RISQUE GÉNÉRAL TABLE DES MATIÈRESINFORMATION RELATIVE À LA SÉCURITÉ INFORMATION RELATIVE ÀLA SÉCURITÉ Suite DÉBALLAGEIDENTIFICATION DU PRODUIT Figure 1 - Modèle à 50 000 BTU/hAPPROVISIONNEMENT EN PROPANE THÉORIE DE FONCTIONNEMENTVENTILATION ASSEMBLAGEINSTALLATION ASSEMBLAGESuite Figure 3 - Retrait de la vis sur le dessusINSTALLATION FONCTIONNEMENTSuite POUR ALLUMER LAPPAREIL DE CHAUFFAGEENTRETIEN FONCTIONNEMENTENTREPOSAGE Figure 11 - Emplacement de la vis darrêt Figure 12 - Retrait ou installation de laPROCÉDURES DENTRETIEN CIRCUIT ÉLECTRIQUESuite VENTILATEURALLUMEUR Figure 14 - Retrait du fil de lallumeur deSOLUTION DÉPANNAGEPROBLÈME OBSERVÉ CAUSE POSSIBLESERVICE TECHNIQUE ACCESSOIRESPÉCIFICATIONS PIÈCES DE RECHANGEVUE DÉTAILLÉE DES PIÈCES MODÈLES RCLP50VA ET 50-F1 2 3 2 2 19 21 29 4LISTE DES PIÈCES MODÈLES RCLP50VA ET 50-FPage 105339-01C SERVICE DE GARANTIE ET DE RÉPARATION SERVICE DE RÉPARATIONCONSERVEZ CETTE GARANTIE GARANTIE LIMITÉE