a.Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off. If you are just cleaning the firepot, there is no need to unplug the appliance.

b.Pull firepot cleaning rod OUT and IN a couple of times to help shake debris loose. If rod is hard to pull, it may be necessary to use your firepot clean-out tool to chip away material that has built up on the bottom plate of the firepot and to push out any clinkers. Larger clinkers may have to be removed from the top of the firepot. Corn clinkers can be especially difficult to break up.

c.The firepot floor plate must be fully closed when finished. See Figure 27.1 on page 27.

WARNING

Fire Risk.

NEVER pull firepot cleaning rods or cleaning slide plates when appliance is operating.

Hot pellets may fall into ashpan and may start a fire or have mis-starts due to lack of vacuum.

4.Cleaning Ash Pan

Frequency: Weekly or every 5 bags of fuel

By: Homeowner

Locate the ash pan underneath the firepot and using a slight pull up and out remove the ash pan. Empty into

anon-combustible container and re-install ash pan.

See Disposal of Ashes.

5.Disposal of Ashes

Frequency: As needed

By: Homeowner

Ashes should be placed in a metal container with a tight-fitting lid. The closed container of ashes should be placed on a non-combustible floor or on the ground, well away from all combustible materials, pending final disposal.

If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have been thoroughly cooled.

3.Ash Removal from Firebox

Frequency: Weekly or more frequently depending on ash build-up.

By: Homeowner

a.There must not be any hot ashes in the firebox during cleaning so allow the appliance to completely cool. The firebox ash should be removed every time the firepot is cleaned. Frequent cleaning of the ash in the firebox will help slow down the build-up of ash in the exhaust blower and vent system.

b.Plug in your appliance, if unplugged, and turn the thermostat on and immediatley shut it off to start the exhaust blower on its cycle time. It will pull fly ash out the exhaust instead of into the room.

c.Open cast hinged face. Directly underneath the firebox door and to the left and right of the firepot are 2 cleaning slide plates with finger holes. Pull both slide plates out and then open the glass door. Sweep the remaining ash from the firebox into the 2 open holes. A paint brush works well for this. Close slide plates.

d.This ash is deposited in the same ash pan as the firepot debris. The ash pan should be emptied every time you clean the firebox. Remember to place the ash and debris into a metal or noncombustible container.

e.The 2 cleaning slide plates must be fully closed when cleaning is complete. See Disposal of Ashes.

WARNING

Disposal of Ashes

Ashes should be placed in metal container with tight fitting lid.

Ashes should be retained in closed container until all cinders have thoroughly cooled.

6.Cleaning the Hopper

Frequency: Monthly or after burning 1 ton of fuel

By: Homeowner

After burning approximately 1 ton of fuel or changing fuels you will need to clean the hopper to prevent saw- dust build-up.

A combination of sawdust and pellets on the auger reduces the amount of fuel supply to the firepot. This can result in nuisance shutdowns and mis-starts.

a.Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off.

bEmpty the hopper of any remaining pellets.

c.Vacuum the hopper and feed tube.

Page 34

7014-188B

February 3, 2010

Image 34
Contents CB1200MI-MBK Hot glass will cause burnsCB1200-I Pellet Insert Welcome to the Quadra-Fire FamilyTable of Contents Listing and Code Approvals Appliance Certification BTU & Efficiency SpecificationsGlass Specifications Mobile Home ApprovedDesign, Installation & Location Consider- ations Appliance LocationThermostat Location CB1200-I Pellet Insert Locating Your Appliance & ChimneyNegative Pressure DraftTools And Supplies Needed CB1200-I Pellet Insert Fire SafetyInspect Appliance & Components and Pre-Use Check List 3Dimensions and Clearances Appliance DimensionsShown with Rear Vent and Optional Outside Air Rear Shroud Kit is Required for Built-In InstallationInch 0mm Clearance to Exposed Section and Face Trim Floor Protection Zero Clearance InstallationsNon-Zero Clearance Installations Inches MillimetersConverting k to R Thermal Conductivity k valueThermal Resistance R value Converting R to kAltering the Factory-Built Fireplace S629M, Standard for 650oC FACTORY-BUILT ChimneysChimney and Exhaust Connection Vent InformationVenting Termination Requirements CB1200-I Pellet Insert Equivalent Feet of Pipe Pipe Selection ChartExample of 3 Elbow-Rear Vent Termination Calculation Venting Systems Full Reline With Outside Air HorizontalCB1200-I Pellet Insert Full Reline With Outside Air Vertical Mobile Home Rear Shroud Installation 7Appliance Set-UpFor Top Vent Installation Rear Vent Installation PreparationInstalling Rear Shroud Attaching Shroud to Hopper BodyTo adjust hopper Adjustable Hopper OptionsGrille Installation CB1200-I Pellet Insert Outside Air Kit InstructionsAdjustable Hearth Support Size 9D x 45W, 2 to 10 Height AdjustmentCB1200-I Pellet Insert Panel and Trim Set CB1200-I Pellet Insert Panel and Trim Set Cont’d Completed ViewCB1200-I Pellet Insert Optional Brick Set Installation Brick Clip InstallationRight Thermostat InstallationTop Log, Left Front LogWood Pellets Shelled Field Corn Cont’d 8Operating InstructionsFuel Size, Material and Storage Shelled Field CornStarting Your First Fire CB1200-I Pellet Insert General Operating InformationBefore Your First Fire Thermostat Calls For HeatFeed Rate Adjustment Instructions CB1200-I Pellet Insert Fire CharacteristicsIgnition Cycles CB1200-I Pellet Insert Frequently Asked Questions Issues SolutionsTroubleshooting SymptomTroubleshooting Cont’d Symptom Possible Cause Corrective ActionTroubleshooting Cont’d Maintaining & Servicing Your Appliance 10Proper Shutdown ProcedureQuick Reference Maintenance Chart Types of FuelCleaning the Hopper Cleaning Firepot with Cleaning Rod & Firepot Clean-Out ToolCleaning Ash Pan See Disposal of Ashes Frequency As neededCleaning Exhaust Path Cleaning Heat Exchanger Chambers & Drop TubeCleaning Beneath Heat Exchanger Cleaning the GlassDoor Gasket Inspection Cleaning Exhaust Blower Requires No LubricationPreparing Firebox for Non-Burn Season Frequency Yearly CB1200-I Pellet Insert High Ash Fuel Content Maintenance Immediate Attention and Cleaning is RequiredBefore removing the side frame. Use a pow Ered Phillips head screw driver to remove ScrewsIgniter Replacement Baffle Removal CB 200-I Pellet Insert Reference MaterialsComponent Function Thermostat Vacuum SwitchWiring Harness See .1 below Snap Disc #1 Convection Blower 125FCB1200-I Pellet Insert Component Locations Control BoxCB1200-I Pellet Insert Exploded Drawing CB1200-I Pellet Insert Service Parts and Accessories Important this is Dated Information HOW to OrderStocked At Depot Description Comments Part Number DR-CB12-NL-BStocked Description Comments Part NumberCB1200-I Pellet Insert Fasteners Stocked at DepotCB1200-I Pellet Insert Service And Maintenance Log Date of Service Performed By Description of ServiceCB1200-I Pellet Insert Warranty Policy CB1200-I Pellet Insert Contact Information