Quadra-Fire CB1200I, CB1200MI-MBK CB1200-I Pellet Insert, Welcome to the Quadra-Fire Family

Page 2

CB1200-I Pellet Insert

R

and Welcome to the Quadra-Fire Family!

Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and performance.

This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum operation of

our stoves, inserts and fireplaces. And yet we are old-fash- ioned when it comes to craftsmanship. Each unit is meticu- lously fabricated and surfaces are hand-finished for lasting beauty and enjoyment. Our pledge to quality is completed as each model undergoes a quality control inspection. From design, to fabrication, to shipping:

We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing Quadra-Fire.

NOTE: Consult insurance carrier, local building inspector, fire officials or authorities having jurisdiction over restrictions, installation inspection and permits.

CLEARANCE TO COMBUSTIBLES LABEL LOCATED INSIDE HOPPER LID

SERIAL NUMBER & MANUFACTURE DATE LABEL LOCATED UNDER TOP ON INSIDE OF HOPPER BODY

CAUTION: HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. Operate this unit with fuel hopper lid closed. Failure to do so may result in emissions products' combustion from the hopper under certain conditions. Maintain hopper seal in good condition. Do no over fill the hopper.

ATTENTION: CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS. Opérez cet appareil avec le couvercle de la trémie fermé. Le défaut de ne pas suivre les instructions peut résulter, sous certaines conditions, en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine.

Safety and clearance section located on inside of hopper lid./Serial Number section located under top on inside of hopper body.

La section se réfé dux distances et mescres de sécurité est située à l'intérieut du couvércle de la tré la bôitre à feu. La section du numéro de série est située en dessous du couvercle à l'intérieur de la trémie.

 

 

 

 

Tested and

 

 

O-T L

 

 

Portland

 

Report / Rapport

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Listed by

 

 

Oregon USA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

US

 

 

 

 

 

#061-S-13-2

 

1200-I Pellet Insert

 

 

1445 Highway North, Colville, WA 99114

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OMNI-Test Laboratories, Inc.

 

 

 

 

 

 

 

 

 

www.quadrafire.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for

Appareil de

chauffage inséré de combustible solide/de type de boulettes. Accepté dans

 

 

 

l'installation

dans les maisons mobiles.

Cet appareil

a été

testé et enregistré pour

 

 

 

Mobile Home Installation. This appliance has been tested and listed for

 

 

 

use in Manufactured Homes in accordance with OAR 814-23-9000

l'usage dans

les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909.

 

 

 

through 814-23-909.

 

 

 

 

 

 

 

 

 

 

 

 

 

Testé

à: ASTM

1509-95,

UL127,

ULC628-M93,

ULC

S610-M87, ULC/ORD

 

 

Tested to: ASTM E1509-95, UL127, ULC S628-93, ULC S610-M87,

C1482-M1990, Room Heating Pellet Burning Type, (UM) 84-HUD POUR USAGE

 

 

AVEC LES BOUL TT S DE BOIS OU DE COMBUSTIBLE DE MAIS ÉCOSSÉ DES

 

 

ULC/ORD C1482-M1990, Room Heating Pellet Burning Type, (UM) 84-HUD

CHAMPS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOR USE ONLY WITH PELLETIZED WOOD OR SHELLED FIELD CORN FUEL.

Consommahon maximale à l'entrée (sans pertes) 2.5 kg/h.

 

 

 

 

 

 

 

 

 

 

Input Rating Maximum 5.5 lb fuel/hr.

 

 

 

 

 

 

Puissance Électrique: 115 VAC, 60 Hz, Début 4.1 Amps, Courir 1.1 Amps,

 

 

Electrical Rating: 115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 AMPS.

 

Éloignez le

fil électrique

de

l'appareil. Ne pas faire passer le fil

électrique au

 

 

 

dessus ou en dessous de l'appareil.

 

 

 

 

 

 

 

 

 

 

 

 

 

Route power cord away from unit. Do not route cord under or in front of

 

 

 

 

 

 

 

 

 

 

 

 

 

DANGER: Il y a risque de décharge électrique. Déconnectez le fil électrique de la

 

 

appliance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Risk of

electrical shock. Disconnect power supply before

prise de contact avant le service.

 

 

 

 

 

 

 

 

 

 

 

 

 

DANGER:

Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez

 

 

servicing. Replace glass only with 5mm ceramic available from your dealer.

votre fournisseur.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To start, set thermostat above room temperature, the stove will light

our allumer, monter la température du thermostat au dessus de la température de

 

 

automatically. To shutdown, set thermostat to below room temperature. For

la pièce, le poêle s'allumera automatiquement.

Pour

éteindre,

descendre la

 

 

further instruction refer to owner's manual.Keep viewing and ash removal doors

température du thermostat en dessous de la température de la pièce. Pour des

 

 

tightly closed during operation.

 

 

 

 

 

 

 

 

 

 

instructions supplémentaires, référez vous au manuel du propriétaire. Gardez la

 

 

 

 

 

 

 

 

 

 

 

 

porte d'ouverture et la porte des cendres fermées hermétiquement durant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

l'opération.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Masonry or Zero Clearance Minimum Clearances to Combustible

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MANTEL

 

 

 

 

 

 

 

 

Maçonnene ou zéro distance foyer distances minimales à tout matériel combustible.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Louvers to combustible wall

 

6” (152mm)

A Lucarne au mur combustible

 

152mm

 

 

 

 

 

WALL

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

B Insert top to mantel

 

 

12” (305mm)

B Dessus de l'insert à la tablette de cheminée

305mm

 

 

 

 

 

SIDE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C Front Facing

 

 

 

3” (76mm)

 

C Revêtement facial

 

 

76mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D* Hearth Extension - Front

 

6" (152mm)

D* Protechion de sol - frontal

 

152mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E* Protechon ole sol - côté

 

 

203mm

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E* Hearth Extension - Side

 

8” (203mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*See hearth protection note above

 

*Voir les notes sur la protechion ole sol ci-dessus.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SAMPLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE

7014-080C

 

 

 

 

U.S. ENVIRONMENTAL PROTECTION AGENCY

OMNI Test Laboratories, Inc., Beaverton, Or Report/Rapport 061-S-12-2

 

 

QUADRA-FIRE

 

 

 

 

 

 

 

 

 

 

This model is exempt from EPA certification under 40 CFR 60.531 by definition [Wood Heater (A) "Air-to-Fuel Ratio"].

 

1200-I PELLET INSERT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2009 2010

2011

 

JAN

 

 

FEB MAR APR MAY JUNE JULY

AUG

SEPT OCT

NOV

DEC

 

 

SERIAL NO. / NUMÉRO DU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

007C

 

 

 

 

 

 

 

 

 

 

 

 

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE

Made in China/Fait Aux Chine

 

 

 

 

 

 

 

7014-080C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test Lab &

Report No.

Model Name

Manufactured Date

Serial Number

Page

7014-188B

February 3, 2010

Image 2
Contents CB1200MI-MBK Hot glass will cause burnsCB1200-I Pellet Insert Welcome to the Quadra-Fire FamilyTable of Contents Listing and Code Approvals Appliance Certification BTU & Efficiency SpecificationsGlass Specifications Mobile Home ApprovedDesign, Installation & Location Consider- ations Appliance LocationThermostat Location CB1200-I Pellet Insert Locating Your Appliance & ChimneyNegative Pressure DraftInspect Appliance & Components and Pre-Use Check List CB1200-I Pellet Insert Fire SafetyTools And Supplies Needed 3Dimensions and Clearances Appliance DimensionsInch 0mm Clearance to Exposed Section and Face Trim Rear Shroud Kit is Required for Built-In InstallationShown with Rear Vent and Optional Outside Air Floor Protection Zero Clearance InstallationsNon-Zero Clearance Installations Inches MillimetersConverting k to R Thermal Conductivity k valueThermal Resistance R value Converting R to kAltering the Factory-Built Fireplace S629M, Standard for 650oC FACTORY-BUILT ChimneysVenting Termination Requirements Vent InformationChimney and Exhaust Connection Example of 3 Elbow-Rear Vent Termination Calculation Pipe Selection ChartCB1200-I Pellet Insert Equivalent Feet of Pipe Venting Systems Full Reline With Outside Air HorizontalCB1200-I Pellet Insert Full Reline With Outside Air Vertical Mobile Home Rear Shroud Installation 7Appliance Set-UpFor Top Vent Installation Rear Vent Installation PreparationInstalling Rear Shroud Attaching Shroud to Hopper BodyTo adjust hopper Adjustable Hopper OptionsGrille Installation CB1200-I Pellet Insert Outside Air Kit InstructionsAdjustable Hearth Support Size 9D x 45W, 2 to 10 Height AdjustmentCB1200-I Pellet Insert Panel and Trim Set CB1200-I Pellet Insert Panel and Trim Set Cont’d Completed ViewCB1200-I Pellet Insert Optional Brick Set Installation Brick Clip InstallationRight Thermostat InstallationTop Log, Left Front LogWood Pellets Shelled Field Corn Cont’d 8Operating InstructionsFuel Size, Material and Storage Shelled Field CornStarting Your First Fire CB1200-I Pellet Insert General Operating InformationBefore Your First Fire Thermostat Calls For HeatIgnition Cycles CB1200-I Pellet Insert Fire CharacteristicsFeed Rate Adjustment Instructions CB1200-I Pellet Insert Frequently Asked Questions Issues SolutionsTroubleshooting SymptomTroubleshooting Cont’d Symptom Possible Cause Corrective ActionTroubleshooting Cont’d Maintaining & Servicing Your Appliance 10Proper Shutdown ProcedureQuick Reference Maintenance Chart Types of FuelCleaning the Hopper Cleaning Firepot with Cleaning Rod & Firepot Clean-Out ToolCleaning Ash Pan See Disposal of Ashes Frequency As neededCleaning Exhaust Path Cleaning Heat Exchanger Chambers & Drop TubeCleaning Beneath Heat Exchanger Cleaning the GlassPreparing Firebox for Non-Burn Season Frequency Yearly Cleaning Exhaust Blower Requires No LubricationDoor Gasket Inspection CB1200-I Pellet Insert High Ash Fuel Content Maintenance Immediate Attention and Cleaning is RequiredBefore removing the side frame. Use a pow Ered Phillips head screw driver to remove ScrewsIgniter Replacement Baffle Removal Component Function Reference MaterialsCB 200-I Pellet Insert Thermostat Vacuum SwitchWiring Harness See .1 below Snap Disc #1 Convection Blower 125FCB1200-I Pellet Insert Component Locations Control BoxCB1200-I Pellet Insert Exploded Drawing CB1200-I Pellet Insert Service Parts and Accessories Important this is Dated Information HOW to OrderStocked At Depot Description Comments Part Number DR-CB12-NL-BStocked Description Comments Part NumberCB1200-I Pellet Insert Fasteners Stocked at DepotCB1200-I Pellet Insert Service And Maintenance Log Date of Service Performed By Description of ServiceCB1200-I Pellet Insert Warranty Policy CB1200-I Pellet Insert Contact Information