Quadra-Fire CB1200MI-MBK, CB1200I Thermostat Installation, Top Log, Left, Right, Front Log

Page 25

R

CB1200-I Pellet Insert

I. Optional Log Set Placement Instructions

CAUTION

Logs are FRAGILE. Use extreme care when handling or cleaning logs.

1.Place the front log in first as shown in Figure 25.1 charred area surrounding firepot.

2.Set the left and right logs onto the front log, placing the holes in the base of the left and right logs over the locating pins in the front log. See Figure 25.2. Ensure that the charred ends are facing the firepot.

LOCATING PINS

Figure 25.1

Charred Areas in the Back

Top Log, Left

Top Log

 

Right

 

Front Log

Figure 25.2

NOTE:

Due to the abrasive nature of a pellet appliance fire, the logs are not covered under warranty. Any placement vari- ation other than shown here can cause excessive heat and shall void the appliance warranty.

J. Thermostat Installation

1. A 12 volt AC thermostat is required to operate this pellet appliance. You may use the included wall mount thermo- stat or purchase an optional programmable thermostat or remote control. The included thermostat is equipped with an adjustable heat anticipator. The current rating is

.05 amps. The anticipator needs to be adjusted to the lowest setting available.

2.When mounting a thermostat on a wall, be sure to follow your thermostat installation instructions carefully.

NOTE: Thermostat must be mounted level for accu- rate readings. The thermostat should be mounted on an inside wall and not in direct line with the appliance convection air. Remove any packaging from inside the thermostat before using.

NOTE: If the thermostat is located too close to the appliance, you may need to set the temperature setting slightly higher to maintain the desired tem- perature in your home.

3.Open right side plane to access a 4 screw terminal block located on the bottom right hand side next to the power cord inlet. The center 2 screws are for the thermostat wires. The outer 2 are the mounting screws for the ter- minal block. Figure 25.3.

Caution

Shock hazard.

• Do NOT remove grounding prong from plug.

Plug directly into properly grounded 3 prong receptacle.

Route cord away from appliance.

Do NOT route cord under or in front of appli- ance.

Terminal Block

Center 2 Screws for

Thermostat Wires

Power Outlet

Figure 25.3

February 3, 2010

7014-188B

Page 25

Image 25
Contents Hot glass will cause burns CB1200MI-MBKWelcome to the Quadra-Fire Family CB1200-I Pellet InsertTable of Contents Glass Specifications Appliance Certification BTU & Efficiency SpecificationsListing and Code Approvals Mobile Home ApprovedAppliance Location Design, Installation & Location Consider- ationsNegative Pressure CB1200-I Pellet Insert Locating Your Appliance & ChimneyThermostat Location DraftTools And Supplies Needed CB1200-I Pellet Insert Fire SafetyInspect Appliance & Components and Pre-Use Check List Appliance Dimensions 3Dimensions and ClearancesShown with Rear Vent and Optional Outside Air Rear Shroud Kit is Required for Built-In InstallationInch 0mm Clearance to Exposed Section and Face Trim Non-Zero Clearance Installations Zero Clearance InstallationsFloor Protection Inches MillimetersThermal Resistance R value Thermal Conductivity k valueConverting k to R Converting R to kS629M, Standard for 650oC FACTORY-BUILT Chimneys Altering the Factory-Built FireplaceChimney and Exhaust Connection Vent InformationVenting Termination Requirements CB1200-I Pellet Insert Equivalent Feet of Pipe Pipe Selection ChartExample of 3 Elbow-Rear Vent Termination Calculation Full Reline With Outside Air Horizontal Venting SystemsCB1200-I Pellet Insert Full Reline With Outside Air Vertical Mobile Home 7Appliance Set-Up Rear Shroud InstallationInstalling Rear Shroud Rear Vent Installation PreparationFor Top Vent Installation Attaching Shroud to Hopper BodyGrille Installation Adjustable Hopper OptionsTo adjust hopper CB1200-I Pellet Insert Outside Air Kit InstructionsSize 9D x 45W, 2 to 10 Height Adjustment Adjustable Hearth SupportCB1200-I Pellet Insert Panel and Trim Set Completed View CB1200-I Pellet Insert Panel and Trim Set Cont’dBrick Clip Installation CB1200-I Pellet Insert Optional Brick Set InstallationTop Log, Left Thermostat InstallationRight Front LogFuel Size, Material and Storage 8Operating InstructionsWood Pellets Shelled Field Corn Cont’d Shelled Field CornBefore Your First Fire CB1200-I Pellet Insert General Operating InformationStarting Your First Fire Thermostat Calls For HeatFeed Rate Adjustment Instructions CB1200-I Pellet Insert Fire CharacteristicsIgnition Cycles Issues Solutions CB1200-I Pellet Insert Frequently Asked QuestionsSymptom TroubleshootingSymptom Possible Cause Corrective Action Troubleshooting Cont’dTroubleshooting Cont’d Quick Reference Maintenance Chart 10Proper Shutdown ProcedureMaintaining & Servicing Your Appliance Types of FuelCleaning Ash Pan Cleaning Firepot with Cleaning Rod & Firepot Clean-Out ToolCleaning the Hopper See Disposal of Ashes Frequency As neededCleaning Beneath Heat Exchanger Cleaning Heat Exchanger Chambers & Drop TubeCleaning Exhaust Path Cleaning the GlassDoor Gasket Inspection Cleaning Exhaust Blower Requires No LubricationPreparing Firebox for Non-Burn Season Frequency Yearly Immediate Attention and Cleaning is Required CB1200-I Pellet Insert High Ash Fuel Content MaintenanceEred Phillips head screw driver to remove Screws Before removing the side frame. Use a powIgniter Replacement Baffle Removal CB 200-I Pellet Insert Reference MaterialsComponent Function Wiring Harness See .1 below Vacuum SwitchThermostat Snap Disc #1 Convection Blower 125FControl Box CB1200-I Pellet Insert Component LocationsCB1200-I Pellet Insert Exploded Drawing Important this is Dated Information HOW to Order CB1200-I Pellet Insert Service Parts and AccessoriesDR-CB12-NL-B Stocked At Depot Description Comments Part NumberDescription Comments Part Number StockedCB1200-I Pellet Insert Stocked at Depot FastenersDate of Service Performed By Description of Service CB1200-I Pellet Insert Service And Maintenance LogCB1200-I Pellet Insert Warranty Policy CB1200-I Pellet Insert Contact Information