Samsung SSA-S2000W user manual To SET or Release the Quick Mode, Buttons and press ENT

Page 28

basic setup

TO SET OR RELEASE THE QUICK MODE

The QUICK mode is applicable to RF ONLY mode (01) and PIN ONLY mode (03) and RF/PIN combination mode (05), which enables you to open the door by simply pressing ENT without the need of the PIN number. (This is useful for the normal business hours when the door entries and exits occur frequently.)

1. Present the Master Card to the device.

2. Press Button 4 and Button 3 in sequence and press ENT .

To release the QUICK mode, repeat Step 1 above, select the

tˆš›Œ™Gjˆ™‹

X Y Z

\ ]

`

lzj W lu{

< 4 4 > buttons and press ENT .

iŒ““

zzhTzYWWW

The default is set to “not used”.

X Y Z

[ \ ]

^ _ `

lzj W lu{

iŒ““

zzhTzYWWW

TO SET OR RELEASE THE TOGGLE MODE FOR THE DOOR RELAY

In the Toggle mode, the door opens if it is closed or vice versa by presenting a registered card or entering the PIN.

1. Present the Master Card to the device.

2. Press Button 4 and Button 5 in sequence and press ENT .

To release the Toggle mode, repeat Step 1 above, select the < 4 6 > buttons and press ENT .

The default is set to “not used”.

tˆš›Œ™Gjˆ™‹

X Y Z

\ ]

`

lzj W lu{

iŒ““

zzhTzYWWW

X Y Z

[\ ] ^ _ `

lzj W lu{

iŒ““

zzhTzYWWW

28_ Basic Setup

Image 28
Contents Standalone Rfid Access Controller Imagine the possibilitiesSafety information Safety informationImportant Safety Instructions This device may not cause harmful interference,Contents To specify the input mode for AUX To specify the input mode for the DoorTo specify the use of the tamper alarm Contact Sensor alarmFeatures Product introductionQuick Guide Rings Diodes UF4004, 1N4001~4007 WHAT’S IncludedMaster Card Cables AT a Glance Front ViewCable Color Scheme Installation and External Connection Cable Selection DC12VBypass Diode Connection ConnectionOutput Connection External Reader Connection Basic Operations InitializationIf you press the Exit button, the door will be opened Wiegand Output Setup InitializationBrown line with white stripes TTL Output Chime Bell OutputForced Initialization with External Line Hardware Forcible InitializationReader Mode Setup RF only Reader mode setupNo Master Card or Master PIN is ever registered Reader Mode Setup RF + P/W Reader Mode Setup PIN onlyEnabling Keypad Input for the Card Number Reader Mode Setup RF/PIN Combination ModeButton User management To Register Cards in RF only ModeRegistering Cards in a Combination of RF and P/W Modes Registering Cards in RF Card / PIN Combination Mode To Register Cards in PIN ModeMaster PIN To Delete a Registered Card or PIN Number Duress Alarm Basic setupTo Specify the Retry Count for AN Unregistered ID To Specify the Delayed Start Time in Secure Mode  See the table below for your referenceTo Specify the Operation Time of the Door Contact Sensor To Specify the Limited Time for the Keypad InputTo Specify the Alarm Output Port for the Dismantled Device To Open or Close the Entry DoorTo SET or Release the Quick Mode To SET or Release the Toggle Mode for the Door RelayDefault is set to not used Buttons and press ENTTo Specify the Output Time if the Card is Authenticated Time setupYou can specify from 10 to To Specify the Output Time if the Card is not Authenticated To Specify the Duress TTL OutputTo Specify the Alarm Operation Time for AUX Enter the two-digit TTL relay output time and press ENT32 I/O Time Setup \ ` To Specify the TTL Output Operation Mode Advanced settingTo SET the Chime Bell Function To Specify the Input Mode for AUX To Specify the Chime Bell Operation Time36 고급 설정 To Specify the Input Mode for the Exit Button To Specify the Input Mode for the Door Contact SensorTo Specify the USE of the Tamper Alarm Additional featuresMute To Check the Output Specified for a Registered Card User To Check the Output Specified for AN Unregistered Card UserTo Check the Output Specified for AUX Press Button 3 and Button 6 in sequence and press ENT Other information Initial ValuesFunction Codes Sense if AUX 1 switches from L to H Sense if AUX 1 switches from H to LSense if AUX 2 switches from L to H Sense if AUX 2 switches from H to LTroubleshooting TroubleshootingTroubleshooting √ RF Only√ Enter the command to delete the user 14 + ENT Service centerEInstall and use the product as usual Check the operation status of the productUsing the keypad Unregistered numbers in 5 consecutive times defaultUser cards to the factory default CIf SSA-S2000 responds when you press the Exit buttonIrrelevant data is transferred Disconnection or short-circuitS2000 Consult with a qualified technicianProduct Specifications Product specificationsCorrect disposal of batteries in this product