Samsung SSA-S2000W user manual Cable Color Scheme

Page 9

CABLE COLOR SCHEME

2-PIN Connector

 

I/O Pins

 

Signal

Cable Color

 

 

 

 

 

Power (+12V)

 

DC +12V

 

Red

Earth-grounding

 

GND(-)

 

Black

 

 

 

 

 

10-PIN Connector

I/O Pins

 

Signal

Cable Color

 

 

 

 

Door Control Relay (NC)

NC(RL1)

 

Blue with White stripes

 

 

 

 

Door Control Relay (COM)

COM(RL1)

 

Gray with Red stripes

 

 

 

 

Door Control Relay (NO)

NO(RL1)

 

White with Red stripes

 

 

 

 

Alarm Relay (NC)

NC(RL2)

 

Purple with White stripes

 

 

 

 

Alarm Relay (COM)

COM(RL2)

 

White

 

 

 

 

Alarm Relay (NO)

NO(RL2)

 

Purple

 

 

 

 

Exit Button

EXIT

 

Orange

 

 

 

 

Door Contact Sensor

CONTACT

 

Yellow with Red stripes

 

 

 

 

Aux Input #1

AUX IN 1

 

Green

 

 

 

 

Aux Input #2

AUX IN 2

 

Green with White stripes

 

 

 

 

7-PIN Connector

I/O Pins

 

Signal

Cable Color

 

 

 

 

Wiegand Data Input 0

DATA_0

 

Pink

 

 

 

 

Wiegand Data Input 1

DATA_1

 

Sky blue

 

 

 

 

TTL Output

TTL

 

Orange with White stripes

 

 

 

 

Chime Bell Output

CHI

 

Brown with White stripes

 

 

 

 

Aux Input #3

AUX IN 3

 

Green with Red stripes

 

 

 

 

RESERVED 1

 

 

Blue with Red stripes

 

 

 

 

RESERVED 2

 

 

Yellow with Red stripes

 

 

 

 

3-PIN Connector

I/O Pins

Signal

Cable Color

 

 

 

RESERVED 1

 

Black with White stripes

 

 

 

RESERVED 2

 

Red with White stripes

 

 

 

RESERVED 3

 

Black

 

 

 

PRODUCT INTRODUCTION

English _ 9

Image 9
Contents Imagine the possibilities Standalone Rfid Access ControllerSafety information Safety informationThis device may not cause harmful interference, Important Safety InstructionsContents To specify the input mode for the Door To specify the input mode for AUXTo specify the use of the tamper alarm Contact Sensor alarmProduct introduction FeaturesWHAT’S Included Quick Guide Rings Diodes UF4004, 1N4001~4007Master Card Cables Front View AT a GlanceCable Color Scheme Installation and External Connection DC12V Cable SelectionConnection Bypass Diode ConnectionOutput Connection External Reader Connection Initialization Basic OperationsIf you press the Exit button, the door will be opened Initialization Wiegand Output SetupBrown line with white stripes TTL Output Chime Bell OutputHardware Forcible Initialization Forced Initialization with External LineReader mode setup Reader Mode Setup RF onlyNo Master Card or Master PIN is ever registered Reader Mode Setup PIN only Reader Mode Setup RF + P/WReader Mode Setup RF/PIN Combination Mode Enabling Keypad Input for the Card NumberButton To Register Cards in RF only Mode User managementRegistering Cards in a Combination of RF and P/W Modes To Register Cards in PIN Mode Registering Cards in RF Card / PIN Combination ModeMaster PIN To Delete a Registered Card or PIN Number Basic setup Duress AlarmTo Specify the Retry Count for AN Unregistered ID  See the table below for your reference To Specify the Delayed Start Time in Secure ModeTo Specify the Limited Time for the Keypad Input To Specify the Operation Time of the Door Contact SensorTo Open or Close the Entry Door To Specify the Alarm Output Port for the Dismantled DeviceTo SET or Release the Toggle Mode for the Door Relay To SET or Release the Quick ModeDefault is set to not used Buttons and press ENTTime setup To Specify the Output Time if the Card is AuthenticatedYou can specify from 10 to To Specify the Duress TTL Output To Specify the Output Time if the Card is not AuthenticatedEnter the two-digit TTL relay output time and press ENT To Specify the Alarm Operation Time for AUX32 I/O Time Setup \ ` Advanced setting To Specify the TTL Output Operation ModeTo SET the Chime Bell Function To Specify the Chime Bell Operation Time To Specify the Input Mode for AUX36 고급 설정 To Specify the Input Mode for the Door Contact Sensor To Specify the Input Mode for the Exit ButtonAdditional features To Specify the USE of the Tamper AlarmMute To Check the Output Specified for AN Unregistered Card User To Check the Output Specified for a Registered Card UserTo Check the Output Specified for AUX Press Button 3 and Button 6 in sequence and press ENT Initial Values Other informationFunction Codes Sense if AUX 1 switches from H to L Sense if AUX 1 switches from L to HSense if AUX 2 switches from L to H Sense if AUX 2 switches from H to LTroubleshooting Troubleshooting√ RF Only TroubleshootingService center √ Enter the command to delete the user 14 + ENTEInstall and use the product as usual Check the operation status of the productUnregistered numbers in 5 consecutive times default Using the keypadUser cards to the factory default CIf SSA-S2000 responds when you press the Exit buttonDisconnection or short-circuit Irrelevant data is transferredS2000 Consult with a qualified technicianProduct specifications Product SpecificationsCorrect disposal of batteries in this product