Samsung SSA-S2000W Using the keypad, If you hear the buzzer sound after a certain time, Manual

Page 48

troubleshooting

Problem

Action

 

 

SSA-S2000 can recognize a

1) Check if the buzzer sounds when you press a key.

presented RF card but can not

- If you hear the buzzer sound

recognize the RF card number

cMaster Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT)

using the keypad.

dEnter the command to enable the keypad input: 73 + ENT

 

 

eFor more information, refer to the section of enabling or disabling the keypad

 

input for a card number in the user manual.

 

- If you hear the buzzer sound after a certain time

 

cThe keypad input will be suspended for one minute (default) if you enter

 

unregistered numbers in 5 consecutive times (default).

 

dTo change the retry count for an unauthenticated access

 

Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT)

 

Enter the command to set the retry count for an unauthenticated access 82 + ENT

 

Enter a new retry count: two digits + ENT (ex. 10 + ENT €the retry count is 10.)

 

For more information, refer to the retry count setting section in the user manual.

 

eTo change the keypad suspension time

 

Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT)

 

Enter the command to change the keypad suspension time: 60 + ENT

 

Enter a new time: two digits + ENT (ex. 10 + ENT € the keypad input will be

 

suspended for 10 minutes.)

 

For more information, refer to the applicable section for the keypad suspension in the user

 

manual.

 

- If the buzzer stays inactive

 

cInitialize the product.

 

Initializing the product will restore all your settings regarding the Master Card

 

and user cards to the factory default.

 

2) If the problem persists after you have followed the procedures above, contact a

 

designated service center.

 

 

The Exit button does not work at

1) Check if the Exit button is connected to SSA-S2000 properly.

all.

- Ensure that the Exit button is of the NO type.

 

2) Check if the Exit button works normally.

 

- Check the connection cable between the Exit button and SSA-S2000 for any disconnection or short-

 

circuit.

 

- Try to connect the two lines on the Exit button.

 

cIf SSA-S2000 responds when you press the Exit button

 

Replace the Exit button  it is defective

 

dIf SSA-S2000 does not respond at all

 

Initialize the product  the product malfunctions or is damaged.

 

(Initializing will restore all data settings to the default.)

 

For more information, refer to the initialization section in the user manual.

 

3) If the problem persists after you have followed the procedures above, contact a

 

designated service center.

 

 

48_ Troubleshooting

Image 48
Contents Standalone Rfid Access Controller Imagine the possibilitiesSafety information Safety informationImportant Safety Instructions This device may not cause harmful interference,Contents To specify the input mode for AUX To specify the input mode for the DoorTo specify the use of the tamper alarm Contact Sensor alarmFeatures Product introductionWHAT’S Included Quick Guide Rings Diodes UF4004, 1N4001~4007Master Card Cables AT a Glance Front ViewCable Color Scheme Installation and External Connection Cable Selection DC12VBypass Diode Connection ConnectionOutput Connection External Reader Connection Initialization Basic OperationsIf you press the Exit button, the door will be opened Wiegand Output Setup InitializationBrown line with white stripes TTL Output Chime Bell OutputForced Initialization with External Line Hardware Forcible InitializationReader mode setup Reader Mode Setup RF onlyNo Master Card or Master PIN is ever registered Reader Mode Setup RF + P/W Reader Mode Setup PIN onlyReader Mode Setup RF/PIN Combination Mode Enabling Keypad Input for the Card NumberButton To Register Cards in RF only Mode User managementRegistering Cards in a Combination of RF and P/W Modes To Register Cards in PIN Mode Registering Cards in RF Card / PIN Combination ModeMaster PIN To Delete a Registered Card or PIN Number Basic setup Duress AlarmTo Specify the Retry Count for AN Unregistered ID To Specify the Delayed Start Time in Secure Mode  See the table below for your referenceTo Specify the Operation Time of the Door Contact Sensor To Specify the Limited Time for the Keypad InputTo Specify the Alarm Output Port for the Dismantled Device To Open or Close the Entry DoorTo SET or Release the Quick Mode To SET or Release the Toggle Mode for the Door RelayDefault is set to not used Buttons and press ENTTime setup To Specify the Output Time if the Card is AuthenticatedYou can specify from 10 to To Specify the Output Time if the Card is not Authenticated To Specify the Duress TTL OutputTo Specify the Alarm Operation Time for AUX Enter the two-digit TTL relay output time and press ENT32 I/O Time Setup \ ` Advanced setting To Specify the TTL Output Operation ModeTo SET the Chime Bell Function To Specify the Input Mode for AUX To Specify the Chime Bell Operation Time36 고급 설정 To Specify the Input Mode for the Exit Button To Specify the Input Mode for the Door Contact SensorAdditional features To Specify the USE of the Tamper AlarmMute To Check the Output Specified for a Registered Card User To Check the Output Specified for AN Unregistered Card UserTo Check the Output Specified for AUX Press Button 3 and Button 6 in sequence and press ENT Other information Initial ValuesFunction Codes Sense if AUX 1 switches from L to H Sense if AUX 1 switches from H to LSense if AUX 2 switches from L to H Sense if AUX 2 switches from H to LTroubleshooting TroubleshootingTroubleshooting √ RF Only√ Enter the command to delete the user 14 + ENT Service centerEInstall and use the product as usual Check the operation status of the productUsing the keypad Unregistered numbers in 5 consecutive times defaultUser cards to the factory default CIf SSA-S2000 responds when you press the Exit buttonIrrelevant data is transferred Disconnection or short-circuitS2000 Consult with a qualified technicianProduct Specifications Product specificationsCorrect disposal of batteries in this product