other information
INITIAL VALUES
This product operates in the following initial values:
For changing the settings or registering/deleting the user card, refer to the applicable section in this document.
1)Entry permitted for a registered card
-The door control relay operates for 3 seconds.
-The green LED indicator flashes for 3 seconds.
2)Entry denied for an unregistered card
-The alarm relay operates for 2 seconds.
-The red LED indicator flashes for 2 seconds.
3)Duress Mode Password : 00
The TTL output port produces a signal for 3 seconds in Duress mode.
4)QUICK MODE : Disabled
5)Chime Bell Output : Enabled
Chime Bell Operating Time : 0.5 second
6)Melody Sound : Enabled
7)Keypad Input Limited Use : 20 seconds
8)When an input signal is sensed : ‘H’ ‘L’ (common for all inputs)
9)When a TTL output signal is sensed : ‘H
10)Patrol Mode Delay Time : 00 minute
11)Door Sensor Sensing Time : 00 second
12)Retry count for an unauthenticated entry : 05 times
13)Alarm for Dismantled Device : Disabled
Dismantled device Alarm Output Port : 02 (Alarm Relay)
14)Toggle Mode : Disabled
15)Control Lock by the Door Sensor : Disabled
42_ Additional Features