PRODUCT SPECIFICATIONS

Item

SSA-S2000

 

 

User

512 Users

 

 

Power / Current

DC 12V / Max.110mA

 

 

Reader Port

External Reder Port 1ea : 26bit Wiegand for Exit

 

 

Reading Time (Card)

30ms

 

 

Door Open Time

00~99 Sec. (Default 3Sec.)

 

 

Input Port

5ea : Exit Button, Door Sensor, Aux#1, #2, #3

 

2ea : 2 Form-C Relay Output (COM, NO, NC) / DC12~18V, Rating Max.2A

Output Port

1ea : Chime Bell Output / DC5V, Rating Max.500mA

 

1ea : TTL Output / DC5V, Rating Max.20mA

 

 

LED Indicator

3 LED Indicators (Red, Green and Orange)

 

 

Beeper

Piezo Buzzer

 

 

Keypad

12 Key Numeric Keypad with Back Lighting

 

 

Operating Temperature

-30°C to +50°C

 

 

Operating Humidity

10% to 90% relative humidity non-condensing

 

 

Color / Material

Silver with Black/ Polycarbonate

Dimension (W x H x

87.0 x 109.0 x 31.0

D(mm))

 

 

 

Weight

220g

 

 

50_ product specifications

Image 50
Contents Standalone Rfid Access Controller Imagine the possibilitiesSafety information Safety informationImportant Safety Instructions This device may not cause harmful interference,Contents To specify the use of the tamper alarm To specify the input mode for AUXTo specify the input mode for the Door Contact Sensor alarmFeatures Product introductionMaster Card Cables WHAT’S IncludedQuick Guide Rings Diodes UF4004, 1N4001~4007 AT a Glance Front ViewCable Color Scheme Installation and External Connection Cable Selection DC12VBypass Diode Connection ConnectionOutput Connection External Reader Connection If you press the Exit button, the door will be opened InitializationBasic Operations Brown line with white stripes Wiegand Output SetupInitialization TTL Output Chime Bell OutputForced Initialization with External Line Hardware Forcible InitializationNo Master Card or Master PIN is ever registered Reader mode setupReader Mode Setup RF only Reader Mode Setup RF + P/W Reader Mode Setup PIN onlyButton Reader Mode Setup RF/PIN Combination ModeEnabling Keypad Input for the Card Number Registering Cards in a Combination of RF and P/W Modes To Register Cards in RF only ModeUser management Master PIN To Register Cards in PIN ModeRegistering Cards in RF Card / PIN Combination Mode To Delete a Registered Card or PIN Number To Specify the Retry Count for AN Unregistered ID Basic setupDuress Alarm To Specify the Delayed Start Time in Secure Mode  See the table below for your referenceTo Specify the Operation Time of the Door Contact Sensor To Specify the Limited Time for the Keypad InputTo Specify the Alarm Output Port for the Dismantled Device To Open or Close the Entry DoorDefault is set to not used To SET or Release the Quick ModeTo SET or Release the Toggle Mode for the Door Relay Buttons and press ENTYou can specify from 10 to Time setupTo Specify the Output Time if the Card is Authenticated To Specify the Output Time if the Card is not Authenticated To Specify the Duress TTL OutputTo Specify the Alarm Operation Time for AUX Enter the two-digit TTL relay output time and press ENT32 I/O Time Setup \ ` To SET the Chime Bell Function Advanced settingTo Specify the TTL Output Operation Mode To Specify the Input Mode for AUX To Specify the Chime Bell Operation Time36 고급 설정 To Specify the Input Mode for the Exit Button To Specify the Input Mode for the Door Contact SensorMute Additional featuresTo Specify the USE of the Tamper Alarm To Check the Output Specified for a Registered Card User To Check the Output Specified for AN Unregistered Card UserTo Check the Output Specified for AUX Press Button 3 and Button 6 in sequence and press ENT Other information Initial ValuesFunction Codes Sense if AUX 2 switches from L to H Sense if AUX 1 switches from L to HSense if AUX 1 switches from H to L Sense if AUX 2 switches from H to LTroubleshooting TroubleshootingTroubleshooting √ RF OnlyEInstall and use the product as usual √ Enter the command to delete the user 14 + ENTService center Check the operation status of the productUser cards to the factory default Using the keypadUnregistered numbers in 5 consecutive times default CIf SSA-S2000 responds when you press the Exit buttonS2000 Irrelevant data is transferredDisconnection or short-circuit Consult with a qualified technicianProduct Specifications Product specificationsCorrect disposal of batteries in this product