TERMINALS

VISTA-40 Installation and Setup Guide

Handset

{

26

27

TERMINALS

 

ON CONTROL

 

BROWN (TIP)

GREY (RING)

{GROUND

Incoming

 

Telco Line

 

28

29

30

GREEN(TIP)

(RING)RED

DIRECT

 

 

CONNECT

 

 

CORD

 

 

PLUG

EARTH GROUND

 

INCOMING TELCO LINE

TIP

RING

RJ31X

TIP

 

PREMISES

RING

 

JACK

 

PHONES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 3-8: Telephone Line Connections

Wiring Burglary, Panic and Smoke Detector Devices to Zones 1-9

The maximum zone resistance is 100 ohms for zones 1 and 8, and 300 ohms for all other zones (excluding the 2K EOL resistor).

To wire burglary and panic devices to zones 1-9, connect sensors/contacts to the hardwire zone terminals (10 through 23). See Figure 3-9. Connect N.C. and N.O. devices as follows:

Connect N.C. devices in series with the high (+) side of the loop. The 2K EOL resistor must be connected in series with the devices, following the last device.

Connect N.O. devices in parallel (across) the loop. The 2K EOL resistor must be connected across the loop wires at the last device.

Red Jumper

ZONE 2 ZONE 3

ZONE 4 ZONE 5

ZONE 6 ZONE 7

ZONE 8 ZONE 9

10

11

12

13

14

15

16

17

18

19

20

21

 

22

23

ZONE 1

 

 

 

 

 

 

 

 

 

LATCHING TYPE GLASS

 

Programmable Response

 

 

supportsNO/NC Burg contacts)

+

-

+

 

 

 

+

-

+

BREAK DETECTORS

(Fast/Normal) Loop

2-WIRE SMOKE DETECTOR LOOP

N.C.

 

N.C.

 

 

 

N.C.

 

N.C.

N.O.

 

N.O.

 

 

 

N.O.

 

N.O.

2k EOLR

 

2k EOLR

 

2k EOLR

 

2k EOLR

 

(Also

 

 

 

+

-

+

 

 

 

+

 

-

+

 

 

 

 

 

 

 

 

 

 

 

+

-

Fire

 

 

 

 

 

GLASS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Usage

 

 

 

 

 

 

 

BREAK

 

 

 

SMOKE

 

 

 

N.C.

 

N.C.

 

 

 

 

 

 

N.C.

 

 

 

 

 

 

 

 

 

N.C.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N.C.

 

 

 

 

N.O.

 

N.O.

 

 

 

N.O.

 

 

N.C.

 

 

Burg.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Usage

2k EOLR

 

2k EOLR

 

 

 

 

 

 

 

N.O.

 

 

 

 

 

2k EOLR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

hw_zones-001-V0

 

Zone resistance (Excluding EOLR):

2k EOLR

ZONE 1,8: 100 OHMS MAXIMUM

ALL OTHER ZONES: 300 OHMS MAXIMUM

 

Zone response time:

ZONES 1-8: 350mSec-500mSec

ZONE 9: Programmable for Fast: 10mSec-15mSec Normal: 350mSec-500mSec

(default response)

Figure 3-9: Wiring Connections for Zones 1-9

3-6

Image 16
Contents $0&29,67$ 3DUWLWLRQHG6HFXULW\6\VWHPQVWDOODWLRQDQG6HWXS*XLGH N7001V5 5/04 Rev APage Table of Contents Index List of Figures Conventions Used in This Manual PRODUCT MODEL NUMBERSFeatures General DescriptionS E C T I O N About the VISTA-40Additional Features VISTA-40Installation and Setup GuideEvent Log Setting-Upa Partitioned System PartitioningTheory of Partitioning S E C T I O NVISTA-40Installation and Setup Guide Installing the Control Installing the Cabinet LockMounting the Control Cabinet Grade A Mercantile Premises Listing GuidelinesVISTA-40Installation and Setup Guide Installing the Control’s Circuit BoardStep Action Installing the Keypads Section 3 - Installing the ControlWire Run Length/Gauge Table Wire GaugeInstalling External Sounders VISTA-40Installation and Setup GuideAlarm Output Supervision Wiring the Alarm OutputTelephone Line Connections Section 3 - Installing the ControlSupervising the Alarm Output Using a Siren DriverVISTA-40Installation and Setup Guide Figure 3-9 Wiring Connections for ZonesTERMINALS ON CONTROLSection 3 - Installing the Control Using 2-WireSmoke Detectors on ZoneCompatible 2-WireSmoke Detectors Using 4-WireSmoke Detectors on ZonesVISTA-40InstallationTOand Setup Guide Using Smoke Power Reversal ModuleInstalling the 333PRM Smoke Detectors Compatible with the 333PRMSection 3 - Installing the Control FOUR-WIREDETECTOR CIRCUITFOUR-WIREDETECTOR CIRCUIT CONTROL PANELInstalling RPM Devices VISTA-40Installation and Setup GuideUsing 2-WireLatching Glassbreaks on Zone 3-10Section 3 - Installing the Control 3-11Step Action Figure 3-16 Polling Loop Connections to theVISTA-40Installation and Setup Guide Using the 4297 Polling Loop Extender3-12 Polling Loop SupervisionWireless Zone Expansion Section 3 - Installing the ControlRF System Installation Advisories Installation and Setup of the 5881 RF ReceiversVISTA-40Installation and Setup Guide 3-14Step Action StepSection 3 - Installing the Control Installing the 5800TM ModuleThe 5800TM must not be installed within 5800 Series Transmitter SetupInstalling Relay Devices VISTA-40Installation and Setup GuideTransmitter Battery Life Installing the 4204 Relay ModulesInstalling the Ground Start Module Section 3 - Installing the ControlInstalling X10 Devices The wire that reads + 50VDC is the RING sideInstalling a Remote Keyswitch VISTA-40Installation and Setup GuideKeyswitch Tamper Operation Wiring for the Remote KeyswitchInstalling a 4100SM Remote Keypad SounderLong Range Radio Connected to the J7 Triggers Section 3 - Installing the ControlInstalling the 4285/4286 VIP Module VISTA-40Installation and Setup GuideConnecting the 4100SM to a Serial Printer UL installationsSection 3 - Installing the Control 3-21Step Action Step ActionVISTA-40Installation and Setup Guide Installing the Audio Alarm Verification Module3-22 Connecting the Transformer Section 3 - Installing the Control3-23 UVCM AND UVST SUMMARY OF CONNECTIONSVISTA-40Installation and Setup Guide Power Limiting Outputs3-24 OutputDetermining the Control’s Power Supply Load Panel Earth Ground ConnectionsSection 3 - Installing the Control AC Power Outlet Ground Available fromDetermining the Size of the Standby Battery VISTA-40Installation and Setup GuideTable 3 Alarm Output Current Load AlarmSection 3 - Installing the Control Table 6 Battery Selection TableRecommended Battery 3-27VISTA-40Installation and Setup Guide 3-28Programming Program ModesEntering and Exiting Programming Mode Data Field Programming Mode#93 Menu Mode Programming VISTA-40Installation and Setup GuideEntry Errors 1Enter Program Mode Installer Code +VISTA-40Installation and Setup Guide #93 Menu Mode Programming CommandsMAIN MENU OPTIONSZone Number Designations VISTA-40Installation and Setup GuideZone Defaults Communication DefaultsZone Response Type Definitions Communication Defaults for ZonesType 05 Trouble by Day/Alarm by Night Section 4 - ProgrammingZone Input Type Definitions VISTA-40Installation and Setup GuideType 06 24-HourSilent Alarm Type 07 24-HourAudible AlarmProgramming for Access Control Programming for 4100SMSection 4 - Programming StepVISTA-40Installation and Setup Guide Data Field Descriptions About Data Field ProgrammingProgramming Data Fields Installer CodeVISTA-40Installation and Setup Guide Alarm Sounder Duration partition-specificKeyswitch Assignment Prevent Fire Timeout24 25 26 Power-Upin Previous StatePABX Access Code Section 5 - Data Field Descriptions38 39 VISTA-40Installation and Setup GuideDownload Command Enables Enable Open/Close report for Keyswitch45 46 47 48 49 Section 5 - Data Field DescriptionsFIELD TITLE and DATA ENTRIES59 60 61 62 VISTA-40Installation and Setup GuideAlarm Code for Zones Alarm Code for Zones74 75 76 77 Supervisory and Restore CodesAlarm Code for Zones Alarm Code for Zones82 83 84 VISTA-40Installation and Setup GuideNon-AlarmReport Codes Second Digit Restore Report Timing1*01 1*02 1*03 1*04 1*05 1*09 1*28 1*29 1*30 1*311*33 1*341*36 1*371*38 1*391*49 1*531*57 1*582*02 2*172*18 2*19Downloading Primer General InformationRemote Downloading is not a UL Listed feature Access SecurityGetting On-Linewith a Control Panel VISTA-40Installation and Setup GuideOn-LineControl Functions Stage What HappensTelco Handoff Direct-WireDownloadingSection 24 - Downloading Primer VISTA-40Installation and Setup Guide Setting the Real-TimeClock Setting the Time and DateS E C T I O N General InformationVISTA-40Installation and Setup Guide User Access Codes User Codes & Levels of AuthorityLevel 0 Installer User 1 Code S E C T I O NMultiple Partition Access VISTA-40Installation and Setup GuideEXAMPLE OF MULTIPLE PARTITION ACCESS Level 6 Duress CodesSection 9 - User Access Codes Adding a Master, Manager, or Operator CodePROMPTEXPLANATION Changing a Master, Manager, or Operator Code Adding an RF Key to an Existing UserDeleting a Master, Manager, or Operator Code Exiting the User Edit ModeTesting the System Battery TestDialer Test Burglary Walk-TestCode + 5 TESTTesting Wireless Transmitters VISTA-40Installation and Setup GuideStep Action 1Enter Installer Code + Transmitter ID Sniffer ModeTo the Installer Trouble ConditionsSection 10 - Testing The System Power FailureVISTA-40Installation and Setup Guide Contacting Technical SupportTechnical Support ATLIS-FAXFAXBACK Automated Fax Retrieval SystemUL Installation Requirements UL365 Police Station Connected Burglar AlarmRegulatory Agency Statements A P P E N D I X AUL611/UL1610 Central Station Burglary Alarm VISTA-40Installation and Setup GuideFor Grade A Service For Grade AA ServiceAppendix A - Regulatory Agency Statements IN THE EVENT OF TELEPHONE OPERATIONAL PROBLEMSFCC PART 68 NOTICE CANADIAN EMISSIONS STATEMENTS VISTA-40Installation and Setup GuideAVIS Summary of System Commands A P P E N D I X BUser Code Commands Programming Commands Event Logging CommandsVISTA-40Installation and Setup Guide Specifications A P P E N D I X CInterface Wiring Interface WiringVISTA-40Installation and Setup Guide Contact ID Event Codes A P P E N D I X DTABLE OF CONTACT ID EVENT CODES CodeVISTA-40Installation and Setup Guide Index Index-1VISTA-40Installation and Setup Guide Index-2Index Index-3VISTA-40Installation and Setup Guide Index-4THE LIMITATIONS OF THIS ALARM SYSTEM LIMITED WARRANTY Page Page Page Page Page Page Page ¬19+l 165 Eileen Way, Syosset, New YorkN7001V5 5/04 Rev A