Using 2-Wire Latching Glassbreaks on Zone 8

VISTA-40 Installation and Setup Guide

Using 2-Wire Latching Glassbreaks on Zone 8

Zone 8 can support 2-wire glassbreak detectors. The zone provides enough standby current to power up to 50 2-wire glassbreak detectors meeting the requirements listed below.

Compatible Glassbreak Detectors

Use detectors that meet the following ratings:

GLASSBREAK

DETECTOR

2000

ZONE 8

(+)

21

OHMS

 

 

EOLR

LATCHING TYPE GLASS

 

 

 

 

BREAK DETECTOR LOOP

(-)

 

22

 

 

Standby

Voltage:

Standby Resistance:

Alarm Resistance:

Alarm

Current:

Reset Time:

5VDC–13.8VDC

Greater than 20k ohms (equivalent resistance of all detectors in parallel)

Less than 1.1k ohms (see note below)

2mA–10mA

Less than 6 seconds

Figure 3-15: Wiring Latching Glassbreaks to Zone 8

The alarm current provided by zone 8 supports only one glassbreak detector in the alarmed state.

Do not use other N.O. or N.C. contacts when using glassbreak detectors on zone 8. Other contacts may prevent proper glassbreak detector operation.

NOTES:

You can use detectors that exceed 1.1k ohms in alarm, provided they maintain a voltage drop of less than 3.8 volts in alarm.

The ASC-SS1 detector has been tested and found to be compatible with these ratings.

To wire 2-wire latching glassbreak detectors to zone 8, perform the following steps:

Step Action

1Select compatible 2-wire glassbreak detectors that meet the requirements stated previously.

2Connect detectors across zone 8 (terminals 21 and 22). See Figure 3-15.

3Connect the EOL resistor at the last detector in the loop across the zone’s terminals. You must connect the EOL resistor across the loop wires at the last detector.

Installing RPM Devices

The polling loop provides both power and data to the RPM devices, and is constantly monitoring the status of all zones enabled on the loop. The maximum current

Compatible Polling Loop Devices

draw of all devices on the polling loop cannot total more than 64mA (unless the system uses a 4297 Polling Loop Extender Module).

Devices that can be programmed via either DIP switches or the built-in unique serial number must be set for the serial number mode operation.

All devices on the polling loop must be wired in parallel to the [+] and [-] polling loop terminals of the control panel (24 and 25). You can wire from device to device, or have multiple branches connected directly to the control panel in a star configuration.

Model Number

4208

4190WH

4278

4275

4194

4297

4192SD

4192SDT

4192CP

4101SN

4208U

4939SN-BR 4939SN-GY

4191SN-WH

4959SN

Type

8-Zone Expander

2-Zone Expander

Quad PIR

Dual PIR

Surface-Mount Reed Contact (Wide Gap)

Extender Module

Photoelectric Smoke Detector Devices

Photoelectric Smoke Detector w/Heat Detector

Ionization Smoke Detector

Serial Number Single-Output Relay Module

Universal 8-Zone Expander

Serial Number Surface-Mount Reed Contacts

Serial Number Recessed Reed Contact

Aluminum Overhead Door Contact

3-10

Image 20
Contents $0&29,67$ 3DUWLWLRQHG6HFXULW\6\VWHPQVWDOODWLRQDQG6HWXS*XLGH N7001V5 5/04 Rev APage Table of Contents Index List of Figures Conventions Used in This Manual PRODUCT MODEL NUMBERSFeatures General DescriptionS E C T I O N About the VISTA-40Event Log VISTA-40Installation and Setup GuideAdditional Features Setting-Upa Partitioned System PartitioningTheory of Partitioning S E C T I O NVISTA-40Installation and Setup Guide Installing the Control Installing the Cabinet LockMounting the Control Cabinet Grade A Mercantile Premises Listing GuidelinesStep Action Installing the Control’s Circuit BoardVISTA-40Installation and Setup Guide Installing the Keypads Section 3 - Installing the ControlWire Run Length/Gauge Table Wire GaugeInstalling External Sounders VISTA-40Installation and Setup GuideAlarm Output Supervision Wiring the Alarm OutputTelephone Line Connections Section 3 - Installing the ControlSupervising the Alarm Output Using a Siren DriverVISTA-40Installation and Setup Guide Figure 3-9 Wiring Connections for ZonesTERMINALS ON CONTROLSection 3 - Installing the Control Using 2-WireSmoke Detectors on ZoneCompatible 2-WireSmoke Detectors Using 4-WireSmoke Detectors on ZonesVISTA-40InstallationTOand Setup Guide Using Smoke Power Reversal ModuleInstalling the 333PRM Smoke Detectors Compatible with the 333PRMSection 3 - Installing the Control FOUR-WIREDETECTOR CIRCUITFOUR-WIREDETECTOR CIRCUIT CONTROL PANELInstalling RPM Devices VISTA-40Installation and Setup GuideUsing 2-WireLatching Glassbreaks on Zone 3-10Section 3 - Installing the Control 3-11Step Action Figure 3-16 Polling Loop Connections to theVISTA-40Installation and Setup Guide Using the 4297 Polling Loop Extender3-12 Polling Loop SupervisionWireless Zone Expansion Section 3 - Installing the ControlRF System Installation Advisories Installation and Setup of the 5881 RF ReceiversVISTA-40Installation and Setup Guide 3-14Step Action StepSection 3 - Installing the Control Installing the 5800TM ModuleThe 5800TM must not be installed within 5800 Series Transmitter SetupInstalling Relay Devices VISTA-40Installation and Setup GuideTransmitter Battery Life Installing the 4204 Relay ModulesInstalling the Ground Start Module Section 3 - Installing the ControlInstalling X10 Devices The wire that reads + 50VDC is the RING sideInstalling a Remote Keyswitch VISTA-40Installation and Setup GuideKeyswitch Tamper Operation Wiring for the Remote KeyswitchInstalling a 4100SM Remote Keypad SounderLong Range Radio Connected to the J7 Triggers Section 3 - Installing the ControlInstalling the 4285/4286 VIP Module VISTA-40Installation and Setup GuideConnecting the 4100SM to a Serial Printer UL installationsSection 3 - Installing the Control 3-21Step Action Step Action3-22 Installing the Audio Alarm Verification ModuleVISTA-40Installation and Setup Guide Connecting the Transformer Section 3 - Installing the Control3-23 UVCM AND UVST SUMMARY OF CONNECTIONSVISTA-40Installation and Setup Guide Power Limiting Outputs3-24 OutputDetermining the Control’s Power Supply Load Panel Earth Ground ConnectionsSection 3 - Installing the Control AC Power Outlet Ground Available fromDetermining the Size of the Standby Battery VISTA-40Installation and Setup GuideTable 3 Alarm Output Current Load AlarmSection 3 - Installing the Control Table 6 Battery Selection TableRecommended Battery 3-27VISTA-40Installation and Setup Guide 3-28Programming Program ModesEntering and Exiting Programming Mode Data Field Programming Mode#93 Menu Mode Programming VISTA-40Installation and Setup GuideEntry Errors 1Enter Program Mode Installer Code +VISTA-40Installation and Setup Guide #93 Menu Mode Programming CommandsMAIN MENU OPTIONSZone Number Designations VISTA-40Installation and Setup GuideZone Defaults Communication DefaultsZone Response Type Definitions Communication Defaults for ZonesType 05 Trouble by Day/Alarm by Night Section 4 - ProgrammingZone Input Type Definitions VISTA-40Installation and Setup GuideType 06 24-HourSilent Alarm Type 07 24-HourAudible AlarmProgramming for Access Control Programming for 4100SMSection 4 - Programming StepVISTA-40Installation and Setup Guide Data Field Descriptions About Data Field ProgrammingProgramming Data Fields Installer CodeVISTA-40Installation and Setup Guide Alarm Sounder Duration partition-specificKeyswitch Assignment Prevent Fire Timeout24 25 26 Power-Upin Previous StatePABX Access Code Section 5 - Data Field Descriptions38 39 VISTA-40Installation and Setup GuideDownload Command Enables Enable Open/Close report for Keyswitch45 46 47 48 49 Section 5 - Data Field DescriptionsFIELD TITLE and DATA ENTRIES59 60 61 62 VISTA-40Installation and Setup GuideAlarm Code for Zones Alarm Code for Zones74 75 76 77 Supervisory and Restore CodesAlarm Code for Zones Alarm Code for Zones82 83 84 VISTA-40Installation and Setup GuideNon-AlarmReport Codes Second Digit Restore Report Timing1*01 1*02 1*03 1*04 1*05 1*09 1*28 1*29 1*30 1*311*33 1*341*36 1*371*38 1*391*49 1*531*57 1*582*02 2*172*18 2*19Downloading Primer General InformationRemote Downloading is not a UL Listed feature Access SecurityGetting On-Linewith a Control Panel VISTA-40Installation and Setup GuideOn-LineControl Functions Stage What HappensSection 24 - Downloading Primer Direct-WireDownloadingTelco Handoff VISTA-40Installation and Setup Guide Setting the Real-TimeClock Setting the Time and DateS E C T I O N General InformationVISTA-40Installation and Setup Guide User Access Codes User Codes & Levels of AuthorityLevel 0 Installer User 1 Code S E C T I O NMultiple Partition Access VISTA-40Installation and Setup GuideEXAMPLE OF MULTIPLE PARTITION ACCESS Level 6 Duress CodesPROMPTEXPLANATION Adding a Master, Manager, or Operator CodeSection 9 - User Access Codes Changing a Master, Manager, or Operator Code Adding an RF Key to an Existing UserDeleting a Master, Manager, or Operator Code Exiting the User Edit ModeTesting the System Battery TestDialer Test Burglary Walk-TestCode + 5 TESTTesting Wireless Transmitters VISTA-40Installation and Setup GuideStep Action 1Enter Installer Code + Transmitter ID Sniffer ModeTo the Installer Trouble ConditionsSection 10 - Testing The System Power FailureVISTA-40Installation and Setup Guide Contacting Technical SupportTechnical Support ATLIS-FAXFAXBACK Automated Fax Retrieval SystemUL Installation Requirements UL365 Police Station Connected Burglar AlarmRegulatory Agency Statements A P P E N D I X AUL611/UL1610 Central Station Burglary Alarm VISTA-40Installation and Setup GuideFor Grade A Service For Grade AA ServiceFCC PART 68 NOTICE IN THE EVENT OF TELEPHONE OPERATIONAL PROBLEMSAppendix A - Regulatory Agency Statements AVIS VISTA-40Installation and Setup GuideCANADIAN EMISSIONS STATEMENTS Summary of System Commands A P P E N D I X BUser Code Commands Programming Commands Event Logging CommandsVISTA-40Installation and Setup Guide Specifications A P P E N D I X CInterface Wiring Interface WiringVISTA-40Installation and Setup Guide Contact ID Event Codes A P P E N D I X DTABLE OF CONTACT ID EVENT CODES CodeVISTA-40Installation and Setup Guide Index Index-1VISTA-40Installation and Setup Guide Index-2Index Index-3VISTA-40Installation and Setup Guide Index-4THE LIMITATIONS OF THIS ALARM SYSTEM LIMITED WARRANTY Page Page Page Page Page Page Page N7001V5 5/04 Rev A 165 Eileen Way, Syosset, New York¬19+l