Honeywell K14114 3/06 Rev.B setup guide Fields 43

Page 22

LYNXR-I Installation and Setup Guide

Data Field Descriptions

All four digits of the Subscriber Account number must be entered in Fields 43 and 44. If ten-digit format is selected in 48 (option 5), all ten digits of the Subscriber Account number must be entered.

Fields 43 and 44:

Enter [] as the fourth digit if a 3-digit account number (for 3+1 dialer reporting format) is used. Enter 0 as the first digit of a 4-digit account number for Nos. 0000–0999. Enter [] as the fifth digit if a 4-digit account number (for 3+1, CID®) is used. Exit field by pressing [] if only 3 digits are used. To clear entries from field, press 43or 44. See blank Programming Form for examples of account number entries. If using the paging feature, do not enter a leading 0 in the subscriber account number, and do not use digits A-F anywhere in the number. Some paging systems provide voice mail capability, which is activated by a leading 0 in the message. Enter digits 0–9; # +11=B; # +12=C; # +13=D; # +14=E; or # +15=F.

43

Primary Subs Account No.

Enter the primary subscriber account number.

Enter a four or ten digit account number.

To clear entries from field, press 43.

 

 

 

44

Secondary Subs Account No.

Enter the secondary subscriber account number.

Enter a four or ten digit account number.

To clear entries from field, press 44.

 

 

 

Field 46: Enter up to 24 digits. Do not fill unused spaces. Enter 0-9, #+11 for ‘*’; #+12 for’#’; #+13 for a pause (2 seconds).

46

 

“Follow Me Reminder” Phone Number

 

 

This option allows the user to schedule a time driven message.

 

Enter up to 24 digits.

 

 

 

 

 

 

 

When activated the system will dial the phone number

 

 

 

 

 

 

 

 

 

programmed and deliver a voice message (custom words 72, 73

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and 74). This option is only supported when the pager or follow

 

 

 

 

 

 

 

 

 

 

 

 

 

me feature is enabled in field 49 (option 6-9 or 10-13).

 

 

 

 

 

 

 

 

 

 

 

 

 

If using the Follow Me Reminder feature, enter the phone number

 

 

 

 

 

 

 

 

 

 

 

 

 

here. If fewer than 24 digits are entered, exit by pressing []. To

 

 

 

 

 

 

 

 

 

 

 

 

 

clear entries from the field press 46.

 

 

 

 

 

 

 

 

 

 

 

 

 

The telephone message can be terminated (acknowledged) by

 

 

 

 

 

 

 

 

 

 

 

 

 

pressing any key on the telephone keypad. Pressing any key on

 

 

 

 

 

 

 

 

 

 

 

 

 

the local LYNXR-I keypad will terminate (acknowledge) both the

 

 

 

 

 

 

 

 

 

 

 

 

 

follow me and the local reminder announcements.

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: The follow me reminder announcement will be terminated if

 

 

 

 

 

 

 

 

 

 

 

 

 

any other event requires the system to dial out or if an

 

 

 

 

 

 

 

 

 

 

 

 

 

audible alarm has occurred.

 

 

 

 

 

 

 

 

 

 

47

 

Phone System Select

 

 

 

 

 

This option is used to enter the correct type of phone dialing

 

 

 

 

 

 

 

 

 

 

 

 

(pulse or tone), and to select the correct WATS line option for the

 

Central

 

 

Dialing

Mode

 

 

 

 

 

 

 

 

 

Central Station. This option is used to activate the Speaker Phone

 

 

 

Station

Pulse

Tone

 

Pulse

 

Tone

 

 

 

 

 

 

 

 

 

option.

 

 

 

No WATS

0 = No

1 = No

 

4 = With

 

5 = With

 

 

 

 

 

 

 

 

 

Note: If using pulse dialing, you must enter the numbers slowly in

 

 

 

 

Speaker

Speaker

 

Speaker

 

Speaker

 

 

 

 

 

 

Phone

Phone

 

Phone

 

Phone

 

 

order to allow the pulse dialer time to operate.

 

 

 

WATS

2 = No

3 = No

 

6 = With

 

7 = With

 

 

 

 

 

 

 

Speaker

Speaker

 

Speaker

 

Speaker

 

 

 

 

 

 

 

Phone

Phone

 

Phone

 

Phone

 

 

 

 

 

 

 

 

 

48

 

Report Format for Primary/Secondary

 

 

Enter as the 4th digit of 43 through 44, if 3+1 dialer

 

Primary

 

 

Secondary

 

 

 

reporting is to be used. (For an explanation of these formats, see

 

 

 

 

 

 

 

 

 

 

the System Communication section of this manual.)

 

 

See choices below

 

See choices below

 

 

 

 

 

 

 

 

 

Notes: (1) The maximum number of alarm and alarm restore

 

 

0 = 3+1; 4+1 ADEMCO Low Speed Standard

 

 

 

 

 

 

 

 

reports during one armed period is determined by field

 

 

1 = 3+1; 4+1 Radionics Standard

 

 

 

 

 

 

 

 

 

 

 

 

92.

 

 

2 = 4+2 ADEMCO Low Speed Standard

 

 

 

 

 

 

 

 

(2) If Option 5 is selected a 10-digit account number must

 

 

3 = 4+2 Radionics Standard

 

 

 

 

 

 

 

 

 

 

 

 

be entered in Fields 43 or 44.

 

 

5 = ADEMCO Contact ID® Reporting with 10-digit

 

 

 

 

 

 

(3) Option 5 or 7 (ADEMCO Contact ID® Reporting) must

 

 

 

subscriber account number

 

 

 

 

 

 

 

 

 

 

 

 

 

be selected for AVM.

 

 

6 = 4+2 ADEMCO Express

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 = ADEMCO Contact ID® Reporting with 4-digit

 

 

 

 

 

 

subscriber account number

 

 

 

 

 

 

 

 

8 = 3+1; 4+1 ADEMCO Low Speed Expanded

 

 

 

 

 

9 = 3+1; 4+1 Radionics Expanded

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 22 -

Image 22
Contents Ademco LYNXR-I Recommendations for Smoke and Heat Detectors Recommendations For Proper Intrusion ProtectionTable of Contents System Features Wall Mounting Mounting the ControlDesktop Mounting Wiring Overview Wiring ConnectionsLYNXR-I Wiring Connections Wiring Connections Full Line Seizure ConnectionsAlarmNet 7845i-L* Communications Device Connecting/Configuring Communication ModulesInstalling the 7845i-L Communications Module GeneralConnecting AlarmNet 7845GSM* / 7845i-GSM Connecting AlarmNet 7845i-ENT/7845iLRR/IP Communications Device 24-Hour Standby Power Connecting AlarmNet 7845CV2AlarmNet 7845CV2 AC Power and Rechargeable Backup Battery AC Power and Backup BatteryBackup battery Distance from TransformerAC Power and Rechargeable Backup Battery Replacing the Rechargeable BatteryGeneral Information Installing Wireless ZonesType Description Enter Installer code 4112 + # + Transmitter Battery LifeUsing the Transmitter Sniffer Mode Go/No Go Test ModeSetting DIP Switches on the 5800RL Transmitter Setting 5800RL DIP SwitchesGeneral Programming Information Entering Program ModeMechanics of Programming Programming a Data FieldInteractive Mode Used to Program Interactive Menu Mode Programming 56, 80, 81, 83, 84Loading Factory Defaults Exiting Program ModeZone Response Type Definitions 5806/5807/5808 Defaults where applicable are Indicated in bold text Data Field DescriptionsDialer Programming Fields 43 Split/Dual Reporting Second Dialer Delay BurglaryEnable/Disable LRR/IP Communications Periodic Test ReportSystem Status and Restore Report Codes Programming 59 76 System Status Report CodesRestore Report Codes Dynamic Signaling Delay/ Dynamic Dynamic Signaling DELAY/DYNAMIC Signaling Priority FieldSignaling Priority = Aux key performs defined function Audio Alarm Verification AAV/RemoteAUX Function/1-Button Paging MacroZone Lists Menu Mode Enhanced Zone Programming ModeDevice Programming Menu Mode Enhanced Sequential ModeEnhanced Zone Programming Mode Report code Zone numberZone type Input typeLoop number or Loop and Serial Delete zone parameters confirmationSerial number Enroll modeVoice descriptor Descriptor Start by Event Device Programming Menu ModeProgramming Options Defined Start by Zone Type or System OperationUpon Restore of a Zone List Programming Powerline Carrier DevicesUpon a Zone Type or System Operation Device number Powerline Carrier DeviceProgramming Device actionZone List Menu Mode Enhanced Sequential Mode IA LC = copy the previous serial number entry from the bufferDelete serial number Assign Zone Voice Descriptors Assign zone voice descriptorsAssign Zone Voice Descriptor Voice Vocabulary IndexAssign custom voice descriptors Record Custom Voice DescriptorsCustom descriptor number Voice Prompt Programming Keypad Functions Voice Prompt ProgrammingDELETE/ Stay key Used to Toenroll Second Central Station Account NumberFront Basement Back Sliding Side Hall Gar ge Kitchen Patio Sensor Type Sensor Location Location ModifiersPendant Type Template selections Template To!Enter Expert Programming ModeTemplate Remote Programming Information Remote Programming/Control DownloadingEquipment required to download to a system at the premises Remote Programming Advisory Notes Security Codes System OperationPanic Keys Message Center Volume ControlKeypad Functions Other FunctionsSpeaker Phone Operation Remote Phone Control FeatureRemote Phone Control Feature Quick Arm NoteOperator Commands Audio Alarm Verification Two-Way Voice FeatureActivation Exit Error Alarm Displays Follow Me System Announcement FeaturePowerline Carrier Devices e.g. X10 devices Display MeaningAlarm System DisplaysArmed System Test Testing the SystemTest Mode Return to normal operationSystem Communication Communication OverviewCode Definition Report +1/4+1 Standard +1/4+1 ExpandedTrouble Conditions Troubleshooting GuideSystem Trouble Displays Symptom Possible Cause Remedy S t e m i n c l u d i n g W i r e l e s sN t r o l Smoke DetectorsProgramming Default Tables Boldface indicates defaults that differ between tablesDefault Duress Code Function Event loggingEvent Start StopDevice Number System OperationIndex House ID Serial Number Federal Communications Commission FCC Part 15 Statement Regulatory Agency StatementsUL Notice This is a Grade a residential system Federal Communications Commission FCC PartLimitations of this Alarm System LYNXR-I SpecificationsRead the Instructions ALL Output Circuits are Power Limited SystemLimited Warranty