Honeywell K14114 3/06 Rev.B setup guide Zone List Menu Mode

Page 37

LYNXR-I Installation and Setup Guide

81 Zone List Menu Mode

While in Program mode, press 81 to enter Zone List Menu Mode. This mode is used to program zone lists for output devices (programmed in 80 menu mode) or Chime-by-Zone in Zone List 3.

NOTES:

Any list may include any or all of the systems zone numbers.

A zone list can be assigned to more than one Powerline Carrier Device.

The prompts for *81 are as follows:

81

Zone List Programming--------------------

Main Menu prompt

A01

b

C

d

E

Zone List Number ---------------------------

for entering the zone list number to be programmed

Zone Entry to List ---------------------------

for entering zones to the assigned zone list

Delete Entire List? --------------------------

for deleting the entire zone list and its contents

Delete Specific Zones From List?--------

Selects whether to delete zones or return to next zone

 

list number

Delete Zones -----------------------------------

for deleting specific zones from the current zone list

The following explains these prompts in detail. The left two columns identify the prompts and list the available entries. The right-most column provides a further explanation of the entries.

Notes: (1) Entering a number other than one specified will give unpredictable results.

(2)Do not assign zones with zone types 20, 21 or 22 to a zone list.

 

 

 

 

Zone list programming

Pressing 1 advances to the next prompt below.

 

 

8I

 

0 = exit mode

Pressing 0 exits mode, upon which this prompt blinks, indicating the

 

 

 

mode is inactive.

 

 

 

1 = enter mode

 

 

 

 

 

 

 

 

 

 

Zone list number

Enter the Zone List Number 01, 02, or 03 to program (or 00 if no

 

A

0I

 

01-03 = zone list number to be programmed

zone lists are used).

 

 

 

 

 

00 = exit Zone List mode

 

 

 

 

 

[] = continue

 

 

 

 

 

 

 

 

 

 

 

Zone entry to list

Enter each zone number to add to the zone list by first entering the

 

b

zz

 

01-41, 95, 96, 99 = zone numbers to add to zone

zone number, then the [] key (for example, 010203). The

 

 

system will announce the Voice Descriptor for the selected zone, if it

 

 

list

 

 

 

 

[] = accept zone number and enter the next zone

is programmed. After all desired zones are enrolled, enter “00” to

 

 

 

 

 

 

 

 

advance.

 

 

 

 

number

 

 

 

 

 

 

 

 

 

00 = accept zone number(s) and continue to next

 

 

 

 

 

prompt

 

 

 

 

 

 

 

 

 

 

 

Delete entire zone list?

To delete the zone list, enter “1”. All zones in the zone list will be

 

C

 

 

0 = don’t delete; continue to next prompt

deleted automatically and programming will return to the ZONE

 

 

 

LIST NUMBER prompt.

 

 

 

1 = delete the current zone list

 

 

 

 

 

To save the zone list or delete specific zones from the list, enter “0”.

 

 

 

 

 

 

 

 

 

 

Delete zones from list?

To save the entire zone list, enter “0” and programming will return

 

d

 

 

1 = continue to delete zones prompt

to the ZONE LIST NUMBER prompt.

 

 

 

To delete a zone or zones in a zone list enter “1”.

 

 

 

0 = don’t delete; continue to next zone list number

 

 

 

 

 

 

 

 

prompt (A….01)

 

 

 

 

 

[#] = return to zone list number prompt (A….01)

 

 

 

 

 

Delete zones

When deleting a zone(s) from the zone list, if the selected zone has a

 

E

 

 

Enter each 2-digit zone number to be deleted from

Voice Descriptor programmed, upon deletion it will be announced as

 

 

 

a confirmation that it has been deleted. After all zones to be deleted

 

 

 

the current zone list, followed by the [] key.

 

 

 

 

[] = delete zone and enter next zone to be

are entered, enter “00” to return to the ZONE LIST NUMBER

 

 

 

 

prompt so that another list can be programmed, if desired.

 

 

 

 

deleted

 

 

 

 

 

 

 

 

 

00 = delete zone and return to next zone list

 

 

 

 

 

number prompt (A….01) desired

 

 

 

 

 

 

 

- 37 -

Image 37
Contents Ademco LYNXR-I Recommendations For Proper Intrusion Protection Recommendations for Smoke and Heat DetectorsTable of Contents System Features Wall Mounting Mounting the ControlDesktop Mounting Wiring Overview Wiring ConnectionsLYNXR-I Wiring Connections Full Line Seizure Connections Wiring ConnectionsInstalling the 7845i-L Communications Module Connecting/Configuring Communication ModulesAlarmNet 7845i-L* Communications Device GeneralConnecting AlarmNet 7845i-ENT/7845i Connecting AlarmNet 7845GSM* / 7845i-GSMLRR/IP Communications Device 24-Hour Standby Power Connecting AlarmNet 7845CV2AlarmNet 7845CV2 Backup battery AC Power and Backup BatteryAC Power and Rechargeable Backup Battery Distance from TransformerReplacing the Rechargeable Battery AC Power and Rechargeable Backup BatteryGeneral Information Installing Wireless ZonesType Description Using the Transmitter Sniffer Mode Transmitter Battery LifeEnter Installer code 4112 + # + Go/No Go Test ModeSetting 5800RL DIP Switches Setting DIP Switches on the 5800RL TransmitterMechanics of Programming Entering Program ModeGeneral Programming Information Programming a Data FieldLoading Factory Defaults Interactive Menu Mode Programming 56, 80, 81, 83, 84Interactive Mode Used to Program Exiting Program ModeZone Response Type Definitions 5806/5807/5808 Data Field Descriptions Defaults where applicable are Indicated in bold textDialer Programming Fields 43 Enable/Disable LRR/IP Communications Second Dialer Delay BurglarySplit/Dual Reporting Periodic Test ReportSystem Status Report Codes System Status and Restore Report Codes Programming 59 76Restore Report Codes Dynamic Signaling Delay/ Dynamic Dynamic Signaling DELAY/DYNAMIC Signaling Priority FieldSignaling Priority AUX Function/1-Button Paging Audio Alarm Verification AAV/Remote= Aux key performs defined function MacroDevice Programming Menu Mode Enhanced Zone Programming ModeZone Lists Menu Mode Enhanced Sequential ModeEnhanced Zone Programming Mode Zone type Zone numberReport code Input typeDelete zone parameters confirmation Loop number or Loop and SerialSerial number Enroll modeVoice descriptor Descriptor Programming Options Defined Device Programming Menu ModeStart by Event Start by Zone Type or System OperationUpon Restore of a Zone List Programming Powerline Carrier DevicesUpon a Zone Type or System Operation Programming Powerline Carrier DeviceDevice number Device actionZone List Menu Mode Enhanced Sequential Mode = copy the previous serial number entry from the buffer IA LCDelete serial number Assign zone voice descriptors Assign Zone Voice DescriptorsVoice Vocabulary Index Assign Zone Voice DescriptorAssign custom voice descriptors Record Custom Voice DescriptorsCustom descriptor number Voice Prompt Programming Keypad Functions Voice Prompt ProgrammingDELETE/ Stay key Used to Front Basement Back Sliding Side Hall Gar ge Kitchen Patio Second Central Station Account NumberToenroll Sensor Type Sensor Location Location ModifiersPendant Type Template selections Template To!Enter Expert Programming ModeTemplate Remote Programming Information Remote Programming/Control DownloadingEquipment required to download to a system at the premises Remote Programming Advisory Notes Security Codes System OperationPanic Keys Keypad Functions Volume ControlMessage Center Other FunctionsRemote Phone Control Feature Remote Phone Control FeatureSpeaker Phone Operation Quick Arm NoteOperator Commands Audio Alarm Verification Two-Way Voice FeatureActivation Powerline Carrier Devices e.g. X10 devices Follow Me System Announcement FeatureExit Error Alarm Displays Display MeaningSystem Displays AlarmTest Mode Testing the SystemArmed System Test Return to normal operationCommunication Overview System CommunicationReport +1/4+1 Standard +1/4+1 Expanded Code DefinitionTrouble Conditions Troubleshooting GuideSystem Trouble Displays S t e m i n c l u d i n g W i r e l e s s Symptom Possible Cause RemedySmoke Detectors N t r o lBoldface indicates defaults that differ between tables Programming Default TablesFunction Event logging Default Duress CodeDevice Number Start StopEvent System OperationIndex House ID Serial Number UL Notice This is a Grade a residential system Regulatory Agency StatementsFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC PartLimitations of this Alarm System LYNXR-I SpecificationsRead the Instructions System ALL Output Circuits are Power LimitedLimited Warranty