Honeywell K14114 3/06 Rev.B Keypad Functions, Message Center, Volume Control, Other Functions

Page 51

LYNXR-I Installation and Setup Guide

System Operation

Keypad Functions

The keypad allows the user to arm and disarm the system, and perform other system functions, such as bypassing zones. Zone and system conditions (alarm, trouble, bypass) are displayed in the display window. When an alarm occurs, keypad sounding and external sounding will occur, and the zone(s) in alarm will be displayed on the keypad. Pressing any key will silence the keypad sounder for 10 seconds (only once). Disarming the system will silence both keypad and external sounders. When the system is disarmed, any zones that were in an alarm condition during the armed period will be displayed (memory of alarm). To clear this display, simply repeat the disarm sequence (enter the security code and press the OFF key). The keypad also features chime annunciation, and 3 panic key pairs for silent, audible, fire or personal emergency alarms. These keys can notify the central station of an alarm condition, if that service is connected. A summary of system functions is provided below for more detailed information refer to the User’s Manual.

Security Functions (Empty boxes represent the user’s security code)

Checking system status:

 

 

 

(high

level

messages); press

 

 

 

again for secondary

STATUS

STATUS

messages

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To arm in STAY mode:

 

 

 

 

 

+

 

 

 

(or installer code + [3])

 

 

 

 

 

 

STAY

To restart exit delay:

 

 

(applies only if system is armed in Stay mode)

STAY

To arm in AWAY mode:

 

 

 

 

 

+

 

 

 

(or installer code + [2])

 

 

 

 

 

 

AWAY

To arm with NO DELAY:

 

 

 

 

 

+

 

or

 

 

+

 

 

 

 

 

 

 

AWAY

STAY

NO DELAY

 

To arm if Quick Arm is programmed:

 

or

 

(hold down for at least 2 seconds)

AWAY

STAY

To disarm the system and silence alarms:

 

 

+

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

Note: During Exit Delay or when an Alarm Condition exists the system can be disarmed by entering the User Code and entering the OFF key is not required.

To bypass a zone(s):

 

To turn Chime mode on or off:

FUNCTION

+

+

CHIME

BYPASS

+ 2-digit zone number(s)

Message Center

 

To record a message:

FUNCTION

To stop recording before end of 90 seconds: OFF

........................To play back a message:

FUNCTION

To skip a message:

[]

To delete all messages:

 

FUNCTION

+

+

+

RECORD

PLAY

DELETE (during message replay)

Volume Control

 

 

 

 

 

 

 

 

 

 

 

 

To adjust message playback/system announcement volume:

 

 

 

 

+

 

 

FUNCTION

VOLUME

To mute system announcements:

 

 

+

 

 

 

+

 

 

 

 

FUNCTION

VOLUME

 

 

OFF

 

 

To restore/unmute announcement & volume:

 

 

+

 

+ [3] or [6]

 

FUNCTION

 

VOLUME

+ [3] or [6]

Other Functions

To set the time and date: .......................

To set the scheduling: .............................

To activate or deactivate X10 devices 1-6:To activate or deactivate X10 devices 7 & 8: To add a user code: .................................

To delete a user code (except Master Code): To turn Test mode on: .............................

To turn Test mode off: ............................

 

+

 

 

 

 

 

 

+ [63]

 

 

 

 

 

 

 

FUNCTION

 

+

 

 

 

 

 

 

+ [64]

 

 

 

 

 

 

 

FUNCTION

 

 

+

 

 

 

 

 

 

or

 

 

 

+ device number

FUNCTION

 

LIGHTS ON

LIGHTS OFF

 

 

 

 

 

+

 

 

 

 

+

 

or

 

+ dev. No.

 

 

 

 

 

FUNCTION

LIGHTS ON

LIGHTS OFF

 

*+

 

 

 

 

+ user number + user’s code (*master code)

 

 

 

CODE

 

 

 

 

 

*+

 

 

+ user number (* master code)

 

 

 

 

 

CODE

+

 

TEST

+

OFF

- 51 -

Image 51
Contents Ademco LYNXR-I Recommendations For Proper Intrusion Protection Recommendations for Smoke and Heat DetectorsTable of Contents System Features Mounting the Control Wall MountingDesktop Mounting Wiring Connections Wiring OverviewLYNXR-I Wiring Connections Full Line Seizure Connections Wiring ConnectionsGeneral Connecting/Configuring Communication ModulesInstalling the 7845i-L Communications Module AlarmNet 7845i-L* Communications DeviceConnecting AlarmNet 7845i-ENT/7845i Connecting AlarmNet 7845GSM* / 7845i-GSMConnecting AlarmNet 7845CV2 LRR/IP Communications Device 24-Hour Standby PowerAlarmNet 7845CV2 Distance from Transformer AC Power and Backup BatteryBackup battery AC Power and Rechargeable Backup BatteryReplacing the Rechargeable Battery AC Power and Rechargeable Backup BatteryInstalling Wireless Zones General InformationType Description Go/No Go Test Mode Transmitter Battery LifeUsing the Transmitter Sniffer Mode Enter Installer code 4112 + # +Setting 5800RL DIP Switches Setting DIP Switches on the 5800RL TransmitterProgramming a Data Field Entering Program ModeMechanics of Programming General Programming InformationExiting Program Mode Interactive Menu Mode Programming 56, 80, 81, 83, 84Loading Factory Defaults Interactive Mode Used to ProgramZone Response Type Definitions 5806/5807/5808 Data Field Descriptions Defaults where applicable are Indicated in bold textDialer Programming Fields 43 Periodic Test Report Second Dialer Delay BurglaryEnable/Disable LRR/IP Communications Split/Dual ReportingSystem Status Report Codes System Status and Restore Report Codes Programming 59 76Restore Report Codes Dynamic Signaling DELAY/DYNAMIC Signaling Priority Field Dynamic Signaling Delay/ DynamicSignaling Priority Macro Audio Alarm Verification AAV/RemoteAUX Function/1-Button Paging = Aux key performs defined functionEnhanced Sequential Mode Enhanced Zone Programming ModeDevice Programming Menu Mode Zone Lists Menu ModeEnhanced Zone Programming Mode Input type Zone numberZone type Report codeDelete zone parameters confirmation Loop number or Loop and SerialEnroll mode Serial numberVoice descriptor Descriptor Start by Zone Type or System Operation Device Programming Menu ModeProgramming Options Defined Start by EventProgramming Powerline Carrier Devices Upon Restore of a Zone ListUpon a Zone Type or System Operation Device action Powerline Carrier DeviceProgramming Device numberZone List Menu Mode Enhanced Sequential Mode = copy the previous serial number entry from the buffer IA LCDelete serial number Assign zone voice descriptors Assign Zone Voice DescriptorsVoice Vocabulary Index Assign Zone Voice DescriptorRecord Custom Voice Descriptors Assign custom voice descriptorsCustom descriptor number Voice Prompt Programming Voice Prompt Programming Keypad FunctionsDELETE/ Stay key Used to Sensor Type Sensor Location Location Modifiers Second Central Station Account NumberFront Basement Back Sliding Side Hall Gar ge Kitchen Patio ToenrollPendant Type To!Enter Expert Programming Mode Template selections TemplateTemplate Remote Programming/Control Downloading Remote Programming InformationEquipment required to download to a system at the premises Remote Programming Advisory Notes System Operation Security CodesPanic Keys Other Functions Volume ControlKeypad Functions Message CenterQuick Arm Note Remote Phone Control FeatureRemote Phone Control Feature Speaker Phone OperationAudio Alarm Verification Two-Way Voice Feature Operator CommandsActivation Display Meaning Follow Me System Announcement FeaturePowerline Carrier Devices e.g. X10 devices Exit Error Alarm DisplaysSystem Displays AlarmReturn to normal operation Testing the SystemTest Mode Armed System TestCommunication Overview System CommunicationReport +1/4+1 Standard +1/4+1 Expanded Code DefinitionTroubleshooting Guide Trouble ConditionsSystem Trouble Displays S t e m i n c l u d i n g W i r e l e s s Symptom Possible Cause RemedySmoke Detectors N t r o lBoldface indicates defaults that differ between tables Programming Default TablesFunction Event logging Default Duress CodeSystem Operation Start StopDevice Number EventIndex House ID Serial Number Federal Communications Commission FCC Part Regulatory Agency StatementsUL Notice This is a Grade a residential system Federal Communications Commission FCC Part 15 StatementLimitations of this Alarm System Specifications LYNXR-IRead the Instructions System ALL Output Circuits are Power LimitedLimited Warranty