Honeywell K14114 3/06 Rev.B setup guide AC Power and Backup Battery, Backup battery

Page 11

LYNXR-I Installation and Setup Guide

AC Power and Backup Battery

The system is powered by a 9VAC, 25VA Plug-in Transformer, ADEMCO K10145X10 (K10145CN in Canada). Refer to the wiring table below for wire gauge and length.

Use only the provided ADEMCO K10145X10 or K10145CN Transformer.

Distance from Transformer

Wire Gauge

to Control

 

 

 

Up to 75 feet

#20

 

 

75 to 150 feet

#18

 

 

150 to 300 feet

#16

 

 

Wiring to the AC Transformer must not exceed 300 feet using 16-gauge wire. The voltage reading between terminals 15 and 16 of the control must not fall below 9.00VAC.

Do not plug the transformer into the AC outlet until after all wiring connections have been made.

Backup battery

In the event of an AC power loss, the system is supported by a long life backup battery that is supervised for connection and for low voltage conditions. If the battery is missing, or a low battery condition is detected, a “low battery” message is displayed and a report is sent to the central station. In addition, the system will beep once every 45 seconds to audibly indicate a low battery condition (press any key to stop the beeping).

AC Power and Rechargeable Backup Battery

Connecting AC Power and backup battery

1.Connect wires from the K10145X10 (K10145CN) in Canada) AC Transformer to terminals 15 and 16 as shown in the wiring diagram.

2.Remove battery retainer.

3.Peel the backing from tape on the back plate.

4.Insert battery pack into back plate.

5.Install battery retainer.

6.Connect battery connector to receptacle on terminal block PC board.

7.After all wiring connections have been made, snap the front assembly to the back plate and plug the transformer into a 24-hour, 110VAC unswitched outlet.

Note: Rechargeable batteries may take up to 48-hours to fully charge. The “LOW BAT” message should clear within four hours or by entering Test Mode.

RETAINER

BATTERY

PACK

TAPE

NOTE

LYNXRCHKIT-HC

BATTERY PACK SHOWN

BATTERY

WIRING

 

RECEPTACLE

TERMINALS

07000-007-V0

Ensure the cover is snapped closed prior to applying AC power.

- 11 -

Image 11
Contents Ademco LYNXR-I Recommendations For Proper Intrusion Protection Recommendations for Smoke and Heat DetectorsTable of Contents System Features Desktop Mounting Mounting the ControlWall Mounting LYNXR-I Wiring Connections Wiring ConnectionsWiring Overview Full Line Seizure Connections Wiring ConnectionsGeneral Connecting/Configuring Communication ModulesInstalling the 7845i-L Communications Module AlarmNet 7845i-L* Communications DeviceConnecting AlarmNet 7845i-ENT/7845i Connecting AlarmNet 7845GSM* / 7845i-GSMAlarmNet 7845CV2 Connecting AlarmNet 7845CV2LRR/IP Communications Device 24-Hour Standby Power Distance from Transformer AC Power and Backup BatteryBackup battery AC Power and Rechargeable Backup BatteryReplacing the Rechargeable Battery AC Power and Rechargeable Backup BatteryType Description Installing Wireless ZonesGeneral Information Go/No Go Test Mode Transmitter Battery LifeUsing the Transmitter Sniffer Mode Enter Installer code 4112 + # +Setting 5800RL DIP Switches Setting DIP Switches on the 5800RL TransmitterProgramming a Data Field Entering Program ModeMechanics of Programming General Programming InformationExiting Program Mode Interactive Menu Mode Programming 56, 80, 81, 83, 84Loading Factory Defaults Interactive Mode Used to ProgramZone Response Type Definitions 5806/5807/5808 Data Field Descriptions Defaults where applicable are Indicated in bold textDialer Programming Fields 43 Periodic Test Report Second Dialer Delay BurglaryEnable/Disable LRR/IP Communications Split/Dual ReportingSystem Status Report Codes System Status and Restore Report Codes Programming 59 76Restore Report Codes Signaling Priority Dynamic Signaling DELAY/DYNAMIC Signaling Priority FieldDynamic Signaling Delay/ Dynamic Macro Audio Alarm Verification AAV/RemoteAUX Function/1-Button Paging = Aux key performs defined functionEnhanced Sequential Mode Enhanced Zone Programming ModeDevice Programming Menu Mode Zone Lists Menu ModeEnhanced Zone Programming Mode Input type Zone numberZone type Report codeDelete zone parameters confirmation Loop number or Loop and SerialVoice descriptor Enroll modeSerial number Descriptor Start by Zone Type or System Operation Device Programming Menu ModeProgramming Options Defined Start by EventUpon a Zone Type or System Operation Programming Powerline Carrier DevicesUpon Restore of a Zone List Device action Powerline Carrier DeviceProgramming Device numberZone List Menu Mode Enhanced Sequential Mode = copy the previous serial number entry from the buffer IA LCDelete serial number Assign zone voice descriptors Assign Zone Voice DescriptorsVoice Vocabulary Index Assign Zone Voice DescriptorCustom descriptor number Record Custom Voice DescriptorsAssign custom voice descriptors DELETE/ Stay key Used to Voice Prompt ProgrammingVoice Prompt Programming Keypad Functions Sensor Type Sensor Location Location Modifiers Second Central Station Account NumberFront Basement Back Sliding Side Hall Gar ge Kitchen Patio ToenrollPendant Type Template To!Enter Expert Programming ModeTemplate selections Template Equipment required to download to a system at the premises Remote Programming/Control DownloadingRemote Programming Information Remote Programming Advisory Notes Panic Keys System OperationSecurity Codes Other Functions Volume ControlKeypad Functions Message CenterQuick Arm Note Remote Phone Control FeatureRemote Phone Control Feature Speaker Phone OperationActivation Audio Alarm Verification Two-Way Voice FeatureOperator Commands Display Meaning Follow Me System Announcement FeaturePowerline Carrier Devices e.g. X10 devices Exit Error Alarm DisplaysSystem Displays AlarmReturn to normal operation Testing the SystemTest Mode Armed System TestCommunication Overview System CommunicationReport +1/4+1 Standard +1/4+1 Expanded Code DefinitionSystem Trouble Displays Troubleshooting GuideTrouble Conditions S t e m i n c l u d i n g W i r e l e s s Symptom Possible Cause RemedySmoke Detectors N t r o lBoldface indicates defaults that differ between tables Programming Default TablesFunction Event logging Default Duress CodeSystem Operation Start StopDevice Number EventIndex House ID Serial Number Federal Communications Commission FCC Part Regulatory Agency StatementsUL Notice This is a Grade a residential system Federal Communications Commission FCC Part 15 StatementLimitations of this Alarm System Read the Instructions SpecificationsLYNXR-I System ALL Output Circuits are Power LimitedLimited Warranty