| 80 Device Programming Menu Mode |
STOP | The "STOP" programming determines when and under what conditions the device will be de- |
| activated. The following options are available: |
Upon Restore of a Zone List
Restore Zone List: If a "ZONE LIST" is used as the “Stop” event, the device will
Upon a Zone Type or System Operation
Zone Type/System Operation: Instead of using a "RESTORE ZONE LIST," a specific zone (response) type or system operation action can be selected to
•If a specific "ZONE TYPE" is chosen, any zone of that response type that restores from a previous alarm, trouble, or fault condition will cause the device to
•If a "SYSTEM OPERATION" is chosen, that operation will cause the device to
During normal system operation, any devices may be manually started by keypad entry of: Code* + [#]
+4 + “n;” or manually stopped by keypad entry of: Code* + [#] + 7 + “n,” where “n” = the device number to be controlled.
*Code is required for devices 7 and 8. For devices
Programming Powerline Carrier Devices
While in program mode, press ✻80 to enter Output Device Menu Mode. This mode is used to program all output devices used in the system. Refer to the output device table for ✻80 on the separate programming form when programming output devices.
Note: The House ID of the Powerline Carrier Devices must be entered in data field ✻25.
The prompts for ✻80 are as follows:
80
Powerline Carrier Device Programming Main Menu prompt
A 01
Device Number | for entering the device number |
b
Device Action | for defining the action the device will perform when active |
C
Start Event Type | for assigning the event type to start the action |
d
Start Zone List | for assigning the zone list to start the action |
E
Start Zone | for assigning the zone type to start the action |
F
Stop Zone List | for assigning the zone list to stop the action |
1A
Stop Zone | for assigning the zone type to stop the action |
- 35 -