Honeywell K14114 3/06 Rev.B setup guide System Displays, Alarm

Page 55

 

 

LYNXR-I Installation and Setup Guide

 

 

System Operation

 

System Displays

 

 

 

 

 

Display

Meaning

 

 

PC

Remote Phone Control feature is active (Appears in place of the clock).

 

 

PH

System Speaker Phone mode is active (Appears in place of the clock).

 

 

AC

AC power is present. If not displayed, the system is operating on backup battery power.

 

 

ALARM

System is armed and an intrusion has been detected (also appears during a

 

 

 

fire alarm or audible emergency alarm). Accompanied by the protection zone

 

 

 

that is in alarm.

 

 

AWAY

All burglary zones, interior and perimeter, are armed.

 

 

BYPASS

One or more burglary protection zones have been bypassed.

 

 

 

 

 

 

CHIME

Chime feature is activate

 

 

FAULT

A malfunction is discovered in the system; or an open is detected in a fire zone; or a

 

 

 

fault in a day/night burglary zone is discovered during a disarmed period.

 

 

 

Accompanied by a display of the zone number in trouble.

 

 

FIRE

A fire alarm or fire fault is present. Accompanied by a display of the zone that

 

 

 

is in alarm

 

 

LOW BAT

Low battery condition in a wireless sensor (if zone number is displayed) or low system

 

 

 

battery (if no zone number is displayed). If 00 is displayed, a wireless keypad has a low

 

 

 

battery condition.

 

 

INSTANT

Entry delay is turned off.

 

 

MESSAGE

A message has been recorded and has not yet been played back.

 

 

 

 

 

 

REC

The system is in Recording mode.

 

 

 

 

 

 

STAY

Perimeter Burglary zones, such as protected windows and doors, are armed

 

 

TEST

System is in Test mode.

 

 

 

 

 

- 55 -

Image 55
Contents Ademco LYNXR-I Recommendations For Proper Intrusion Protection Recommendations for Smoke and Heat DetectorsTable of Contents System Features Wall Mounting Mounting the ControlDesktop Mounting Wiring Overview Wiring ConnectionsLYNXR-I Wiring Connections Full Line Seizure Connections Wiring ConnectionsGeneral Connecting/Configuring Communication ModulesInstalling the 7845i-L Communications Module AlarmNet 7845i-L* Communications DeviceConnecting AlarmNet 7845i-ENT/7845i Connecting AlarmNet 7845GSM* / 7845i-GSMLRR/IP Communications Device 24-Hour Standby Power Connecting AlarmNet 7845CV2AlarmNet 7845CV2 Distance from Transformer AC Power and Backup BatteryBackup battery AC Power and Rechargeable Backup BatteryReplacing the Rechargeable Battery AC Power and Rechargeable Backup BatteryGeneral Information Installing Wireless ZonesType Description Go/No Go Test Mode Transmitter Battery LifeUsing the Transmitter Sniffer Mode Enter Installer code 4112 + # +Setting 5800RL DIP Switches Setting DIP Switches on the 5800RL TransmitterProgramming a Data Field Entering Program ModeMechanics of Programming General Programming InformationExiting Program Mode Interactive Menu Mode Programming 56, 80, 81, 83, 84Loading Factory Defaults Interactive Mode Used to ProgramZone Response Type Definitions 5806/5807/5808 Data Field Descriptions Defaults where applicable are Indicated in bold textDialer Programming Fields 43 Periodic Test Report Second Dialer Delay BurglaryEnable/Disable LRR/IP Communications Split/Dual ReportingSystem Status Report Codes System Status and Restore Report Codes Programming 59 76Restore Report Codes Dynamic Signaling Delay/ Dynamic Dynamic Signaling DELAY/DYNAMIC Signaling Priority FieldSignaling Priority Macro Audio Alarm Verification AAV/RemoteAUX Function/1-Button Paging = Aux key performs defined functionEnhanced Sequential Mode Enhanced Zone Programming ModeDevice Programming Menu Mode Zone Lists Menu ModeEnhanced Zone Programming Mode Input type Zone numberZone type Report codeDelete zone parameters confirmation Loop number or Loop and SerialSerial number Enroll modeVoice descriptor Descriptor Start by Zone Type or System Operation Device Programming Menu ModeProgramming Options Defined Start by EventUpon Restore of a Zone List Programming Powerline Carrier DevicesUpon a Zone Type or System Operation Device action Powerline Carrier DeviceProgramming Device numberZone List Menu Mode Enhanced Sequential Mode = copy the previous serial number entry from the buffer IA LCDelete serial number Assign zone voice descriptors Assign Zone Voice DescriptorsVoice Vocabulary Index Assign Zone Voice DescriptorAssign custom voice descriptors Record Custom Voice DescriptorsCustom descriptor number Voice Prompt Programming Keypad Functions Voice Prompt ProgrammingDELETE/ Stay key Used to Sensor Type Sensor Location Location Modifiers Second Central Station Account NumberFront Basement Back Sliding Side Hall Gar ge Kitchen Patio ToenrollPendant Type Template selections Template To!Enter Expert Programming ModeTemplate Remote Programming Information Remote Programming/Control DownloadingEquipment required to download to a system at the premises Remote Programming Advisory Notes Security Codes System OperationPanic Keys Other Functions Volume ControlKeypad Functions Message CenterQuick Arm Note Remote Phone Control FeatureRemote Phone Control Feature Speaker Phone OperationOperator Commands Audio Alarm Verification Two-Way Voice FeatureActivation Display Meaning Follow Me System Announcement FeaturePowerline Carrier Devices e.g. X10 devices Exit Error Alarm DisplaysSystem Displays AlarmReturn to normal operation Testing the SystemTest Mode Armed System TestCommunication Overview System CommunicationReport +1/4+1 Standard +1/4+1 Expanded Code DefinitionTrouble Conditions Troubleshooting GuideSystem Trouble Displays S t e m i n c l u d i n g W i r e l e s s Symptom Possible Cause RemedySmoke Detectors N t r o lBoldface indicates defaults that differ between tables Programming Default TablesFunction Event logging Default Duress CodeSystem Operation Start StopDevice Number EventIndex House ID Serial Number Federal Communications Commission FCC Part Regulatory Agency StatementsUL Notice This is a Grade a residential system Federal Communications Commission FCC Part 15 StatementLimitations of this Alarm System LYNXR-I SpecificationsRead the Instructions System ALL Output Circuits are Power LimitedLimited Warranty