Honeywell K14114 3/06 Rev.B setup guide Mounting the Control, Wall Mounting, Desktop Mounting

Page 5

LYNXR-I Installation and Setup Guide

Mounting the Control

Wall Mounting

The illustration below shows the front assembly separated from the back plate.

!

DO NOT disconnect the ribbon cable from the terminal strip board. Disconnect the cable only from the front assembly board.

1.Release the front assembly from the back plate by depressing the two locking tabs at the top of the unit with the blade of a medium size screwdriver.

2.Once these tabs have been released, insert the screwdriver in the side of the case and release the side locking tabs by gently twisting.

3.Carefully disconnect the ribbon cable from the front assembly, leaving the ribbon cable connected to the terminal block PC board. The back plate contains the terminal block for making wiring connections.

4.Mount the back plate to a sturdy wall, feeding the field wiring through the appropriate openings in the back plate.

5.After wiring connections are made, carefully reconnect the ribbon cable to the front assembly PC board connector (properly aligning the red wire).

6.Snap the front assembly to the back plate so it is secured by the locking tabs.

LOCKING

TABS

LOCKING TABS

RED WIRE

MARKINGLOCKING

TABS

DISCONNECT

THIS END ONLY!

07000-003-V1

Desktop Mounting

For desktop use the optional mounting base (model LYNX-DM, purchased separately) must be used.

1.Slide the control panel onto the mounting base locking tabs.

2.Bring all wiring through the bottom of the mounting base, using one of the three wire entry locations, before making connections to the control panel.

3.Use tie-wraps to secure the wiring to the built-in wire loops as needed. Use the two supplied screws to secure the control panel to the mounting base.

OFF

ESCAPE

AWAY

ADD

STAY

DELETE

AUX

SELECT

WIRE ENTRY KNOCKOUT (1 of 3)

01009-004-V1

- 5 -

Image 5
Contents Ademco LYNXR-I Recommendations For Proper Intrusion Protection Recommendations for Smoke and Heat DetectorsTable of Contents System Features Desktop Mounting Mounting the ControlWall Mounting LYNXR-I Wiring Connections Wiring ConnectionsWiring Overview Full Line Seizure Connections Wiring ConnectionsInstalling the 7845i-L Communications Module Connecting/Configuring Communication ModulesAlarmNet 7845i-L* Communications Device GeneralConnecting AlarmNet 7845i-ENT/7845i Connecting AlarmNet 7845GSM* / 7845i-GSMAlarmNet 7845CV2 Connecting AlarmNet 7845CV2LRR/IP Communications Device 24-Hour Standby Power Backup battery AC Power and Backup BatteryAC Power and Rechargeable Backup Battery Distance from TransformerReplacing the Rechargeable Battery AC Power and Rechargeable Backup BatteryType Description Installing Wireless ZonesGeneral Information Using the Transmitter Sniffer Mode Transmitter Battery LifeEnter Installer code 4112 + # + Go/No Go Test ModeSetting 5800RL DIP Switches Setting DIP Switches on the 5800RL TransmitterMechanics of Programming Entering Program ModeGeneral Programming Information Programming a Data FieldLoading Factory Defaults Interactive Menu Mode Programming 56, 80, 81, 83, 84Interactive Mode Used to Program Exiting Program ModeZone Response Type Definitions 5806/5807/5808 Data Field Descriptions Defaults where applicable are Indicated in bold textDialer Programming Fields 43 Enable/Disable LRR/IP Communications Second Dialer Delay BurglarySplit/Dual Reporting Periodic Test ReportSystem Status Report Codes System Status and Restore Report Codes Programming 59 76Restore Report Codes Signaling Priority Dynamic Signaling DELAY/DYNAMIC Signaling Priority FieldDynamic Signaling Delay/ Dynamic AUX Function/1-Button Paging Audio Alarm Verification AAV/Remote= Aux key performs defined function MacroDevice Programming Menu Mode Enhanced Zone Programming ModeZone Lists Menu Mode Enhanced Sequential ModeEnhanced Zone Programming Mode Zone type Zone numberReport code Input typeDelete zone parameters confirmation Loop number or Loop and SerialVoice descriptor Enroll modeSerial number Descriptor Programming Options Defined Device Programming Menu ModeStart by Event Start by Zone Type or System OperationUpon a Zone Type or System Operation Programming Powerline Carrier DevicesUpon Restore of a Zone List Programming Powerline Carrier DeviceDevice number Device actionZone List Menu Mode Enhanced Sequential Mode = copy the previous serial number entry from the buffer IA LCDelete serial number Assign zone voice descriptors Assign Zone Voice DescriptorsVoice Vocabulary Index Assign Zone Voice DescriptorCustom descriptor number Record Custom Voice DescriptorsAssign custom voice descriptors DELETE/ Stay key Used to Voice Prompt ProgrammingVoice Prompt Programming Keypad Functions Front Basement Back Sliding Side Hall Gar ge Kitchen Patio Second Central Station Account NumberToenroll Sensor Type Sensor Location Location ModifiersPendant Type Template To!Enter Expert Programming ModeTemplate selections Template Equipment required to download to a system at the premises Remote Programming/Control DownloadingRemote Programming Information Remote Programming Advisory Notes Panic Keys System OperationSecurity Codes Keypad Functions Volume ControlMessage Center Other FunctionsRemote Phone Control Feature Remote Phone Control FeatureSpeaker Phone Operation Quick Arm NoteActivation Audio Alarm Verification Two-Way Voice FeatureOperator Commands Powerline Carrier Devices e.g. X10 devices Follow Me System Announcement FeatureExit Error Alarm Displays Display MeaningSystem Displays AlarmTest Mode Testing the SystemArmed System Test Return to normal operationCommunication Overview System CommunicationReport +1/4+1 Standard +1/4+1 Expanded Code DefinitionSystem Trouble Displays Troubleshooting GuideTrouble Conditions S t e m i n c l u d i n g W i r e l e s s Symptom Possible Cause RemedySmoke Detectors N t r o lBoldface indicates defaults that differ between tables Programming Default TablesFunction Event logging Default Duress CodeDevice Number Start StopEvent System OperationIndex House ID Serial Number UL Notice This is a Grade a residential system Regulatory Agency StatementsFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC PartLimitations of this Alarm System Read the Instructions SpecificationsLYNXR-I System ALL Output Circuits are Power LimitedLimited Warranty