LYNXR-I Installation and Setup Guide

 

56 Enhanced Zone Programming Mode

 

 

 

 

 

 

 

 

 

 

 

Enroll mode

If “L” is displayed, the serial number for this transmitter has already

 

IA

LC

 

0 = advance to the VOICE DESCRIPTOR

been entered. It may, however, still be viewed, confirmed (only if in

 

 

listen mode), or deleted.

 

 

prompt (1C).

 

 

 

 

 

 

 

 

 

Note: This will save all zone parameters.

View serial number

 

 

 

 

 

1 = enter now and proceed to SERIAL

 

 

 

 

 

Enter “3”. Each digit will be redisplayed, and the keypad will beep once

 

 

 

 

 

NUMBER prompt (1b).

for digits 1-6, and three times for the last digit.

 

 

 

 

 

Note: Not applicable if the serial number is already

 

 

 

 

 

 

 

present.

Confirm serial number

 

 

 

 

 

2 = copy the last serial number entered into

The serial number/loop number combination can be confirmed after one

 

 

 

 

 

transmission from a BR type device or two transmissions (fault and

 

 

 

 

 

local ram.

 

 

 

 

 

restore) from a UR or RF type device. If a transmission is received that

 

 

 

 

 

Note: If this is the 1st zone, none will be in the buffer

 

 

 

 

 

matches the serial number and loop number entered, the system will

 

 

 

 

 

and the panel will emit a long tone. Not valid if

confirm the reception by announcing the Voice Descriptor for the zone,

 

 

 

 

 

serial number is already present.

if it is programmed, followed by three beeps, and a “C” will appear on

 

 

 

 

 

3 = view existing serial number.

the display indicating the received serial number and loop number

 

 

 

 

 

Note: Only if “L” is displayed. If “L” is not displayed,

have been confirmed. No further transmissions will be received.

 

 

 

 

 

panel will emit a long beep.

Delete serial number

 

 

 

 

 

9 = advance to F; delete existing serial

 

 

 

 

 

The serial number can be deleted by entering “9”.

 

 

 

 

 

number.

 

 

 

 

 

 

 

 

 

 

 

 

Note: Only if “L” is displayed. If “L” is not displayed,

If “L” is not displayed, the serial number for this transmitter has not

 

 

 

 

 

panel will emit a long beep.

 

 

 

 

 

been previously entered. You may enter the serial number manually,

 

 

 

 

 

[] = advance to the VOICE DESCRIPTOR

 

 

 

 

 

copy the previous serial number, return to Prompt (E) or enter the

 

 

 

 

 

prompt (1C). This will save all zone

serial number later using the 83 Enhanced Sequential Mode.

 

 

 

 

 

parameters.

Manual entry

 

 

 

 

 

[#] = return to the LOOP NUMBER prompt (E).

 

 

 

 

 

Enter "1" to advance to Serial number prompt (1b).

 

 

 

 

 

Note: In order for all entered parameters to be

 

 

 

 

 

Copy the previous serial number

 

 

 

 

 

accepted, you must advance to the VOICE

Enter “2” to copy the previous serial number entered.

 

 

 

 

 

DESCRIPTOR prompt (1C).

Return to Prompt (E)

 

 

 

 

 

 

Enter “#” to return to Loop Number prompt (E).

 

 

 

 

 

 

Enter transmitter later

 

 

 

 

 

 

Enter “0” or “” if you wish to enter the transmitter later, using the

 

 

 

 

 

 

83 Enhanced Sequential Mode described later in this manual.

 

 

 

 

 

 

Notes: (1) The panel will listen only when it is in the idle loop waiting

 

 

 

 

 

 

for key entry and a serial number has been entered. If a key

 

 

 

 

 

 

is entered, the function must be completed and the panel

 

 

 

 

 

 

will listen again.

 

 

 

 

 

 

(2) A long beep indicates illegal entry or duplicate serial number/loop

 

 

 

 

 

 

entry

 

 

 

 

 

Serial number

In this mode, the transmitter serial numbers can only be entered

 

Ib

 

 

 

Enter the transmitter’s 7-digit serial number.

manually.

 

 

 

 

 

 

 

 

 

 

 

[#] = return to prompt 1A and reject any serial

Enter the

7-digit serial number printed on the transmitter. If an

 

 

 

 

 

numbers entries that have been made.

 

 

 

 

 

incorrect digit is entered, press the [#] key to backup to prompt (1A)

 

 

 

 

 

[] = return to prompt 1A, (if a valid serial

 

 

 

 

 

and start over. When all 7 digits are entered, press the [] key.

 

 

 

 

 

number has been entered, the "L" is

 

 

 

 

 

 

 

displayed and the serial number will be

If 52 seconds passes and no entry has been made, the system returns

 

 

 

 

 

copied into EEROM from the last serial

to prompt (1A).

 

 

 

 

 

entered into the buffer.)

Notes: (1) If the serial and loop number combination is already

 

 

 

 

 

Note: This prompt can be used only to manually

 

 

 

 

 

 

present the keypad will emit a single long beep and the

 

 

 

 

 

enroll a serial number. RF enrollment will be

 

system will return to the (1A) prompt and “L” will be

 

 

 

 

 

rejected and the current zone descriptor will be

 

displayed.

 

 

 

 

 

announced, followed by a single long beep

(2)

If less than 7 digits have been entered, the keypad will

 

 

 

 

 

and the system will return to prompt (1A).

 

emit a single long beep and return to the (1A) prompt

 

 

 

 

 

 

 

without displaying the “L”.

 

 

 

 

 

 

(3)

If more than 7 digits have been entered, the first 6 digits

 

 

 

 

 

 

 

will be saved along with the last digit that was entered

 

 

 

 

 

 

 

(entering 123456789 yields the serial number 1234569).

 

 

 

 

 

 

 

 

 

 

 

 

Voice descriptor

Each zone can have a voice descriptor of up to 3 words that will be

 

IC

 

 

 

0 = skip to next zone (A)

announced whenever the system announces status for that zone.

 

 

 

 

 

 

 

 

 

 

1 = enter descriptor mode; existing descriptor

 

 

 

 

 

 

 

for this zone will be announced

 

 

 

 

 

 

 

 

 

 

- 32 -

Image 32
Contents Ademco LYNXR-I Recommendations for Smoke and Heat Detectors Recommendations For Proper Intrusion ProtectionTable of Contents System Features Desktop Mounting Mounting the ControlWall Mounting LYNXR-I Wiring Connections Wiring ConnectionsWiring Overview Wiring Connections Full Line Seizure ConnectionsConnecting/Configuring Communication Modules Installing the 7845i-L Communications ModuleAlarmNet 7845i-L* Communications Device GeneralConnecting AlarmNet 7845GSM* / 7845i-GSM Connecting AlarmNet 7845i-ENT/7845iAlarmNet 7845CV2 Connecting AlarmNet 7845CV2LRR/IP Communications Device 24-Hour Standby Power AC Power and Backup Battery Backup batteryAC Power and Rechargeable Backup Battery Distance from TransformerAC Power and Rechargeable Backup Battery Replacing the Rechargeable BatteryType Description Installing Wireless ZonesGeneral Information Transmitter Battery Life Using the Transmitter Sniffer ModeEnter Installer code 4112 + # + Go/No Go Test ModeSetting DIP Switches on the 5800RL Transmitter Setting 5800RL DIP SwitchesEntering Program Mode Mechanics of ProgrammingGeneral Programming Information Programming a Data FieldInteractive Menu Mode Programming 56, 80, 81, 83, 84 Loading Factory DefaultsInteractive Mode Used to Program Exiting Program ModeZone Response Type Definitions 5806/5807/5808 Defaults where applicable are Indicated in bold text Data Field DescriptionsDialer Programming Fields 43 Second Dialer Delay Burglary Enable/Disable LRR/IP CommunicationsSplit/Dual Reporting Periodic Test ReportSystem Status and Restore Report Codes Programming 59 76 System Status Report CodesRestore Report Codes Signaling Priority Dynamic Signaling DELAY/DYNAMIC Signaling Priority FieldDynamic Signaling Delay/ Dynamic Audio Alarm Verification AAV/Remote AUX Function/1-Button Paging= Aux key performs defined function MacroEnhanced Zone Programming Mode Device Programming Menu ModeZone Lists Menu Mode Enhanced Sequential ModeEnhanced Zone Programming Mode Zone number Zone typeReport code Input typeLoop number or Loop and Serial Delete zone parameters confirmationVoice descriptor Enroll modeSerial number Descriptor Device Programming Menu Mode Programming Options DefinedStart by Event Start by Zone Type or System OperationUpon a Zone Type or System Operation Programming Powerline Carrier DevicesUpon Restore of a Zone List Powerline Carrier Device ProgrammingDevice number Device actionZone List Menu Mode Enhanced Sequential Mode IA LC = copy the previous serial number entry from the bufferDelete serial number Assign Zone Voice Descriptors Assign zone voice descriptorsAssign Zone Voice Descriptor Voice Vocabulary IndexCustom descriptor number Record Custom Voice DescriptorsAssign custom voice descriptors DELETE/ Stay key Used to Voice Prompt ProgrammingVoice Prompt Programming Keypad Functions Second Central Station Account Number Front Basement Back Sliding Side Hall Gar ge Kitchen PatioToenroll Sensor Type Sensor Location Location ModifiersPendant Type Template To!Enter Expert Programming ModeTemplate selections Template Equipment required to download to a system at the premises Remote Programming/Control DownloadingRemote Programming Information Remote Programming Advisory Notes Panic Keys System OperationSecurity Codes Volume Control Keypad FunctionsMessage Center Other FunctionsRemote Phone Control Feature Remote Phone Control FeatureSpeaker Phone Operation Quick Arm NoteActivation Audio Alarm Verification Two-Way Voice FeatureOperator Commands Follow Me System Announcement Feature Powerline Carrier Devices e.g. X10 devicesExit Error Alarm Displays Display MeaningAlarm System DisplaysTesting the System Test ModeArmed System Test Return to normal operationSystem Communication Communication OverviewCode Definition Report +1/4+1 Standard +1/4+1 ExpandedSystem Trouble Displays Troubleshooting GuideTrouble Conditions Symptom Possible Cause Remedy S t e m i n c l u d i n g W i r e l e s sN t r o l Smoke DetectorsProgramming Default Tables Boldface indicates defaults that differ between tablesDefault Duress Code Function Event loggingStart Stop Device NumberEvent System OperationIndex House ID Serial Number Regulatory Agency Statements UL Notice This is a Grade a residential systemFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC PartLimitations of this Alarm System Read the Instructions SpecificationsLYNXR-I ALL Output Circuits are Power Limited SystemLimited Warranty