LYNXR-I Installation and Setup Guide

Programming Default Tables

56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLES 3 & 4

Zone No.

Zone Type

Alarm Code

Input Type

Loop Number

 

Zone Descriptor

2

1

1,0

3 (RF)

2

47, 04 (FRONT DOOR)

3

1

1,0

3 (RF)

2

33, 04 (BACK DOOR)

4

3

1,0

3 (RF)

2

80

(WINDOW)

5

3

1,0

3 (RF)

2

80

(WINDOW)

6

3

1,0

3 (RF)

2

80

(WINDOW)

7

3

1,0

3 (RF)

2

80

(WINDOW)

8

10

1,0

3 (RF)

1

56

(MOTION DETECTOR)

9

9

1,0

3 (RF)

1

22, 02 (SMOKE DETECTOR)

26

21

1,0

5 (BR)

3

 

 

27

22

1,0

5 (BR)

2

 

 

28

23

0,0

5 (BR)

4

 

 

29

23

0,0

5 (BR)

1

 

 

30

21

1,0

5 (BR)

3

 

 

31

22

1,0

5 (BR)

2

 

 

32

23

0,0

5 (BR)

4

 

 

33

23

0,0

5 (BR)

1

 

 

92

---

1,0

---

---

 

 

99

6

1,0

---

---

 

 

NOTE: Zone 2 to 41 are RF zones; Zone 92 is Duress; Zone 99 is keypad panic

80 DEFAULT TABLE: APPLIES TO DEFAULT TABLE 4 (devices 2-7 have no default values)

 

 

 

Start

 

 

Stop

 

 

 

 

Zone Type

Restore of

Zone type

Device Number

Action

Event

Zone List

System Operation

Zone List

System operation

1

2

2

1

 

2

 

8**

2

 

 

33

 

36

**NOTE: If using an X10 Powerhouse Security SH10A siren as device 8, you must change the device action default to “3” if using default table 4.

80 DEFAULT TABLE: APPLIES TO DEFAULT TABLE 1 and 2 (devices 1-7 have no default values)

 

 

 

Start

 

 

Stop

 

 

 

 

Zone Type

Restore of

Zone type

Device Number

Action

Event

Zone List

System Operation

Zone List

System operation

8**

2

 

 

33

 

36

81 ZONE LIST FOR OUTPUT DEVICES DEFAULT TABLE: Applies To Default Table 1 - 4.

Zone List 1

28, 32

Zone List 2

29, 33

Zone List 3

2, 3

- 64 -

Image 64
Contents Ademco LYNXR-I Recommendations for Smoke and Heat Detectors Recommendations For Proper Intrusion ProtectionTable of Contents System Features Wall Mounting Mounting the ControlDesktop Mounting Wiring Overview Wiring ConnectionsLYNXR-I Wiring Connections Wiring Connections Full Line Seizure ConnectionsConnecting/Configuring Communication Modules Installing the 7845i-L Communications ModuleAlarmNet 7845i-L* Communications Device GeneralConnecting AlarmNet 7845GSM* / 7845i-GSM Connecting AlarmNet 7845i-ENT/7845iLRR/IP Communications Device 24-Hour Standby Power Connecting AlarmNet 7845CV2AlarmNet 7845CV2 AC Power and Backup Battery Backup batteryAC Power and Rechargeable Backup Battery Distance from TransformerAC Power and Rechargeable Backup Battery Replacing the Rechargeable BatteryGeneral Information Installing Wireless ZonesType Description Transmitter Battery Life Using the Transmitter Sniffer ModeEnter Installer code 4112 + # + Go/No Go Test ModeSetting DIP Switches on the 5800RL Transmitter Setting 5800RL DIP SwitchesEntering Program Mode Mechanics of ProgrammingGeneral Programming Information Programming a Data FieldInteractive Menu Mode Programming 56, 80, 81, 83, 84 Loading Factory DefaultsInteractive Mode Used to Program Exiting Program ModeZone Response Type Definitions 5806/5807/5808 Defaults where applicable are Indicated in bold text Data Field DescriptionsDialer Programming Fields 43 Second Dialer Delay Burglary Enable/Disable LRR/IP CommunicationsSplit/Dual Reporting Periodic Test ReportSystem Status and Restore Report Codes Programming 59 76 System Status Report CodesRestore Report Codes Dynamic Signaling Delay/ Dynamic Dynamic Signaling DELAY/DYNAMIC Signaling Priority FieldSignaling Priority Audio Alarm Verification AAV/Remote AUX Function/1-Button Paging= Aux key performs defined function MacroEnhanced Zone Programming Mode Device Programming Menu ModeZone Lists Menu Mode Enhanced Sequential ModeEnhanced Zone Programming Mode Zone number Zone typeReport code Input typeLoop number or Loop and Serial Delete zone parameters confirmationSerial number Enroll modeVoice descriptor Descriptor Device Programming Menu Mode Programming Options DefinedStart by Event Start by Zone Type or System OperationUpon Restore of a Zone List Programming Powerline Carrier DevicesUpon a Zone Type or System Operation Powerline Carrier Device ProgrammingDevice number Device actionZone List Menu Mode Enhanced Sequential Mode IA LC = copy the previous serial number entry from the bufferDelete serial number Assign Zone Voice Descriptors Assign zone voice descriptorsAssign Zone Voice Descriptor Voice Vocabulary IndexAssign custom voice descriptors Record Custom Voice DescriptorsCustom descriptor number Voice Prompt Programming Keypad Functions Voice Prompt ProgrammingDELETE/ Stay key Used to Second Central Station Account Number Front Basement Back Sliding Side Hall Gar ge Kitchen PatioToenroll Sensor Type Sensor Location Location ModifiersPendant Type Template selections Template To!Enter Expert Programming ModeTemplate Remote Programming Information Remote Programming/Control DownloadingEquipment required to download to a system at the premises Remote Programming Advisory Notes Security Codes System OperationPanic Keys Volume Control Keypad FunctionsMessage Center Other FunctionsRemote Phone Control Feature Remote Phone Control FeatureSpeaker Phone Operation Quick Arm NoteOperator Commands Audio Alarm Verification Two-Way Voice FeatureActivation Follow Me System Announcement Feature Powerline Carrier Devices e.g. X10 devicesExit Error Alarm Displays Display MeaningAlarm System DisplaysTesting the System Test ModeArmed System Test Return to normal operationSystem Communication Communication OverviewCode Definition Report +1/4+1 Standard +1/4+1 ExpandedTrouble Conditions Troubleshooting GuideSystem Trouble Displays Symptom Possible Cause Remedy S t e m i n c l u d i n g W i r e l e s sN t r o l Smoke DetectorsProgramming Default Tables Boldface indicates defaults that differ between tablesDefault Duress Code Function Event loggingStart Stop Device NumberEvent System OperationIndex House ID Serial Number Regulatory Agency Statements UL Notice This is a Grade a residential systemFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC PartLimitations of this Alarm System LYNXR-I SpecificationsRead the Instructions ALL Output Circuits are Power Limited SystemLimited Warranty