Honeywell K14114 3/06 Rev.B setup guide Descriptor

Page 33

 

 

 

 

 

 

LYNXR-I Installation and Setup Guide

 

 

 

 

 

56 Enhanced Zone Programming Mode

 

 

 

 

 

 

 

 

 

 

 

Descriptor 1

† see 84 Assign Zone Voice Descriptors section for vocabulary index

 

 

Id

 

 

 

vi

 

Enter [#] + 2-digit vocabulary index number† of

Use the [6] or [8] key to advance as described.

 

 

 

first descriptor word for this zone.

 

 

 

To change the entered index number before pressing [6] or [8], simply

 

 

 

 

 

6 = accept word and advance to descriptor 2

 

 

 

 

 

press [#] + desired 2-digit vocabulary index number.

 

 

 

 

 

(descriptor 2 will be announced)

 

 

 

 

 

If descriptor 1 is not desired, enter [#] + 99 (blank), then press [8] to

 

 

 

 

 

8 = accept word and advance to next zone

return to zone number prompt.

 

 

 

 

 

(prompt A) – entire zone descriptor will be

 

 

 

 

 

 

announced

 

 

 

 

 

 

Press any other key to repeat the selected word.

 

 

 

 

 

 

 

 

 

 

 

 

 

Descriptor 2

† see 84 Assign Zone Voice Descriptors section for vocabulary index

 

 

IE

 

 

 

vi

 

Enter [#] + 2-digit vocabulary index number† of

 

 

 

 

second descriptor word for this zone.

Use the [6] or [8] key to advance as described.

 

 

 

 

 

6 = accept word and advance to descriptor 3

To change the entered index number before pressing [6] or [8], simply

 

 

 

 

 

(descriptor 3 will be announced)

press [#] + desired 2-digit vocabulary index number.

 

 

 

 

 

8 = accept word and advance to next zone

If descriptor 2 is not desired, enter [#] + 99 (blank), then press [8] to

 

 

 

 

 

return to zone number prompt.

 

 

 

 

 

(prompt A) – entire zone descriptor will be

 

 

 

 

 

 

 

 

 

 

 

announced

 

 

 

 

 

 

Press any other key to repeat the selected word.

 

 

 

 

 

 

 

 

 

 

 

 

 

Descriptor 3

† see 84 Assign Zone Voice Descriptors section for vocabulary index

 

 

 

 

 

 

IF

vi

 

Enter [#] + 2-digit vocabulary index number† of

Use the [6] or [8] key to advance as described.

 

 

 

third descriptor word for this zone.

 

 

 

To change the entered index number before pressing [6] or [8], simply

 

 

 

 

 

6 or 8 = accept word and advance to next zone

 

 

 

 

 

press [#] + desired 2-digit vocabulary index number.

 

 

 

 

 

(prompt A) – entire zone descriptor will

 

 

 

 

 

If descriptor 3 is not desired, enter [#] + 99 (blank), then press [8] to

 

 

 

 

 

be announced

return to zone number prompt.

 

 

 

 

 

Press any other key to repeat the selected word.

 

 

 

 

 

 

 

 

- 33 -

Image 33
Contents Ademco LYNXR-I Recommendations For Proper Intrusion Protection Recommendations for Smoke and Heat DetectorsTable of Contents System Features Mounting the Control Wall MountingDesktop Mounting Wiring Connections Wiring OverviewLYNXR-I Wiring Connections Full Line Seizure Connections Wiring ConnectionsInstalling the 7845i-L Communications Module Connecting/Configuring Communication ModulesAlarmNet 7845i-L* Communications Device GeneralConnecting AlarmNet 7845i-ENT/7845i Connecting AlarmNet 7845GSM* / 7845i-GSMConnecting AlarmNet 7845CV2 LRR/IP Communications Device 24-Hour Standby PowerAlarmNet 7845CV2 Backup battery AC Power and Backup BatteryAC Power and Rechargeable Backup Battery Distance from TransformerReplacing the Rechargeable Battery AC Power and Rechargeable Backup BatteryInstalling Wireless Zones General InformationType Description Using the Transmitter Sniffer Mode Transmitter Battery LifeEnter Installer code 4112 + # + Go/No Go Test ModeSetting 5800RL DIP Switches Setting DIP Switches on the 5800RL TransmitterMechanics of Programming Entering Program ModeGeneral Programming Information Programming a Data FieldLoading Factory Defaults Interactive Menu Mode Programming 56, 80, 81, 83, 84Interactive Mode Used to Program Exiting Program ModeZone Response Type Definitions 5806/5807/5808 Data Field Descriptions Defaults where applicable are Indicated in bold textDialer Programming Fields 43 Enable/Disable LRR/IP Communications Second Dialer Delay BurglarySplit/Dual Reporting Periodic Test ReportSystem Status Report Codes System Status and Restore Report Codes Programming 59 76Restore Report Codes Dynamic Signaling DELAY/DYNAMIC Signaling Priority Field Dynamic Signaling Delay/ DynamicSignaling Priority AUX Function/1-Button Paging Audio Alarm Verification AAV/Remote= Aux key performs defined function MacroDevice Programming Menu Mode Enhanced Zone Programming ModeZone Lists Menu Mode Enhanced Sequential ModeEnhanced Zone Programming Mode Zone type Zone numberReport code Input typeDelete zone parameters confirmation Loop number or Loop and SerialEnroll mode Serial numberVoice descriptor Descriptor Programming Options Defined Device Programming Menu ModeStart by Event Start by Zone Type or System OperationProgramming Powerline Carrier Devices Upon Restore of a Zone ListUpon a Zone Type or System Operation Programming Powerline Carrier DeviceDevice number Device actionZone List Menu Mode Enhanced Sequential Mode = copy the previous serial number entry from the buffer IA LCDelete serial number Assign zone voice descriptors Assign Zone Voice DescriptorsVoice Vocabulary Index Assign Zone Voice DescriptorRecord Custom Voice Descriptors Assign custom voice descriptorsCustom descriptor number Voice Prompt Programming Voice Prompt Programming Keypad FunctionsDELETE/ Stay key Used to Front Basement Back Sliding Side Hall Gar ge Kitchen Patio Second Central Station Account NumberToenroll Sensor Type Sensor Location Location ModifiersPendant Type To!Enter Expert Programming Mode Template selections TemplateTemplate Remote Programming/Control Downloading Remote Programming InformationEquipment required to download to a system at the premises Remote Programming Advisory Notes System Operation Security CodesPanic Keys Keypad Functions Volume ControlMessage Center Other FunctionsRemote Phone Control Feature Remote Phone Control FeatureSpeaker Phone Operation Quick Arm NoteAudio Alarm Verification Two-Way Voice Feature Operator CommandsActivation Powerline Carrier Devices e.g. X10 devices Follow Me System Announcement FeatureExit Error Alarm Displays Display MeaningSystem Displays AlarmTest Mode Testing the SystemArmed System Test Return to normal operationCommunication Overview System CommunicationReport +1/4+1 Standard +1/4+1 Expanded Code DefinitionTroubleshooting Guide Trouble ConditionsSystem Trouble Displays S t e m i n c l u d i n g W i r e l e s s Symptom Possible Cause RemedySmoke Detectors N t r o lBoldface indicates defaults that differ between tables Programming Default TablesFunction Event logging Default Duress CodeDevice Number Start StopEvent System OperationIndex House ID Serial Number UL Notice This is a Grade a residential system Regulatory Agency StatementsFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC PartLimitations of this Alarm System Specifications LYNXR-IRead the Instructions System ALL Output Circuits are Power LimitedLimited Warranty