Excalibur electronic P95-LP3, P95-NG3 Optional Brick Panels, LOG SET Installation

Page 27

INSTALLATION

OPTIONAL

BRICK PANELS

1)Open the bottom louver door. Loosen the 2 screws holding the Burner ON/OFF switch and bracket to the bottom louver and lift the assembly out.

2)Remove facade.

3)Remove glass door. Remove logs.

LOG SET

INSTALLATION

Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.

Log Kit # 770-930 contains the following pieces:

4)Place Log 312 on the front right side of the burner, fi tting the log on the 2 pins.

312

Note: The logs must not be in the unit.

4)Insert the back brick panel fi rst by carefully slipping it between the back wall of the fi rebox and the rear log bracket.

5)Put the side panels in next. Slide them in from the front and push them fl at up against the wall. Be very careful not to scratch them on the fi rebox hardware.

6)Install the 2 brick retaining clips, one on each side.

a)

306

Rear Log

5) Position Log 311 across the notch in Log

b)

307

Middle Left Log

c)

308

Center Right Log

306 and rest the bottom of the log into the

d)

309

Middle Right Log

2nd grate tab.

e)310 Front Left Log

f)311 Center Left Log

g)312 Front Bottom Log

h)

Embers

902-154

 

i)

Vermiculite

902-179

306

 

 

311

306

307

Notch

3092nd Grate Tab

311

3086) Position Log 308 across the log landing in Log 311. Rest the bottom of the log against the 5th grate tab.

310312

The 3-digit numbers (ie. 312) are

 

molded into the rear of each log.

311

308

NOTE: If you will be installing the optional Brick Panels, install the Brick Panels prior to installing the logs.

Note: If the bottom brick panel must be removed: Remove the Rear Log Stand, then remove the Burner Tray. See the instructions in the "Removing Valve" section.

1)Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.

2)Sprinkle the vermiculite all over the top of the base brick panel.

3)Place Log 306 on the rear log support pins with the fl at side to the back.

306

Pins on the rear log support.

5th Grate Tab

7)Fit the bottom of Log 307 into the bracket on the left side of the burner.

307

Bracket

Excalibur® P95-3 Zero Clearance Direct Vent Gas Fireplace

27

Image 27
Contents 07/17/06 P95-3 Zero Clearance Direct Vent Gas FireplaceTo the New Owner CongratulationsTable of Contents Copy of Safety Decal for P95-3 Safety LabelFor the State of Massachusetts only RequirementsImportant Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistOptional Heat Release KIT Locating Your GAS FireplaceManufactured Mobile Home Additional Requirements Optional Heatwave Duct System KITUnit Base STAND-OFFS Framing DimensionsCombustible Mantels Framing FinishingFloor Mounted Fireplaces Raised Fireplaces Facing RequirementHearth Requirements Facing Over 1 25mm ThickSide Nailing Strips Unit Assembly Prior to InstallationTop Standoff Assembly Venting IntroductionFPI Direct Vent System Flex Horizontal Terminations Only VentingExterior Vent Termination Locations Alternate Horizontal Termination Cap Flat Wall Installation Wall Thickness Vent Length RequiredCorner Installation Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List DescriptionParts not supplied by Dura-Vent FPI Direct Vent System Flex Venting Arrangements Horizontal TerminationsOption + V1 H + H1 Horizontal Venting with Two 2 90o ElbowsHorizontal Venting with Three 3 90o Elbows Option + H1Vertical Venting with Two 2 90o Elbows Vertical Venting with Three 3 90o ElbowsOption Simpson DURA-VENT Direct Vent GS System Venting Arrangements Vertical TerminationsInstallation Snorkel Terminations Below Grade InstallationContinue to assemble pipe lengths Vertical TerminationGS 8 Nominal Diameter ID Offset Installation ProceduresOffset Chart For FPI Direct Vent System FlexHigh Elevation Pilot AdjustmentGAS Line Installation GAS Pipe Pressure TestingInstallation of LPG Conversion Kit Installation of the DC Sparker Heat Shield Optional Brick Panels LOG SET InstallationPicture below is a view from the back of the burner Tab Screw Glass Door InstallationOptional Screen Doors Front FacadeSingle Door Accents Accent KIT InstallationWall Thermostat Thermostat Wire TableDo not cut the ground terminal off under any circumstances Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesMaintenance To Remove the Fans FAN MaintenanceTo Install the Fans Shut the power offInstalling Valve Removing ValveBrick panel is very fragile handle with care P95-3 Main Assembly Parts ListParts List P95-3 Burner Assembly & LOG SET Description P95-3 Flush Front AccessoriesWarranty Limited Lifetime WarrantyInstaller Please complete the following information