Excalibur electronic P95-NG3, P95-LP3 Picture below is a view from the back of the burner

Page 28

INSTALLATION

8)Place the top of Log 307 across the notch on Log 311.

11)Fit Log 310 on the pin and then swing the front end of the log to hit the fi rst grate

12)Place the embers on the front of the burner tray.

306

311

307

310

Notch

Pin

9)PlacethebackofLog309againstthebracket on the top right side of the burner.

The picture below is a view from the back of the burner.

309

Rest log against

bracket306 Rear Log

311

Place embers on the burner tray.

DO NOT BLOCK BURNER HOLES

13)Test fi re to ensure proper light off (make sure fl ame fl ows smoothly from one end of burner to the other). If there is any fl ame hesitation, check that area for any blockage of the burner ports.

14)Reverse steps 1-3 under the "Optional Brick Panels" section.

307

309

Middle Left Log

Middle Right Log

10)Place the top of Log 309 on Log 308, supported by the knot.

309

308

Knot

310

Front Left Log

311

312

308

Center Left Log

Front Bottom Log

Center Right Log

28

Excalibur® P95-3 Zero Clearance Direct Vent Gas Fireplace

Image 28
Contents P95-3 Zero Clearance Direct Vent Gas Fireplace 07/17/06Congratulations To the New OwnerTable of Contents Safety Label Copy of Safety Decal for P95-3Requirements For the State of Massachusetts onlyInstallation General Safety InformationInstallation Checklist Important Message Save These InstructionsLocating Your GAS Fireplace Manufactured Mobile Home Additional RequirementsOptional Heatwave Duct System KIT Optional Heat Release KITFraming Dimensions Combustible MantelsFraming Finishing Unit Base STAND-OFFSFacing Requirement Hearth RequirementsFacing Over 1 25mm Thick Floor Mounted Fireplaces Raised FireplacesUnit Assembly Prior to Installation Top Standoff AssemblyVenting Introduction Side Nailing StripsVenting FPI Direct Vent System Flex Horizontal Terminations OnlyExterior Vent Termination Locations Flat Wall Installation Wall Thickness Vent Length Required Corner InstallationSimpson DURA-VENT Venting Alternate Horizontal Termination CapDescription Simpson DURA-VENT Venting Components ListParts not supplied by Dura-Vent Venting Arrangements Horizontal Terminations FPI Direct Vent System FlexHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsOption + H1 Option + V1 H + H1Vertical Venting with Three 3 90o Elbows Vertical Venting with Two 2 90o ElbowsOption Venting Arrangements Vertical Terminations Simpson DURA-VENT Direct Vent GS SystemInstallation Below Grade Installation Snorkel TerminationsVertical Termination Continue to assemble pipe lengthsInstallation Procedures Offset ChartFor FPI Direct Vent System Flex GS 8 Nominal Diameter ID OffsetPilot Adjustment GAS Line InstallationGAS Pipe Pressure Testing High ElevationInstallation of LPG Conversion Kit Installation of the DC Sparker Heat Shield LOG SET Installation Optional Brick PanelsPicture below is a view from the back of the burner Glass Door Installation Optional Screen DoorsFront Facade Tab ScrewAccent KIT Installation Single Door AccentsThermostat Wire Table Wall ThermostatWiring Diagrams Do not cut the ground terminal off under any circumstancesFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Normal Operating Sounds of GAS Appliances Copy of the Lighting Plate InstructionsMaintenance FAN Maintenance To Install the FansShut the power off To Remove the FansRemoving Valve Installing ValveBrick panel is very fragile handle with care Parts List P95-3 Main AssemblyParts List P95-3 Burner Assembly & LOG SET P95-3 Flush Front Accessories DescriptionWarranty Warranty Limited LifetimeInstaller Please complete the following information