Excalibur electronic P95-LP3, P95-NG3 installation manual Parts List, P95-3 Main Assembly

Page 39

PARTS LIST

Part #

Description

1)430-129 Receptacle Box Mount

2) *

Thermodisc Bracket

7)910-428 Duplex Receptacle

8)910-429 Box - Receptacle

9)910-430 Cover - Receptacle

10)904-687 Clamp Connector

22)770-033 Baffle Guide

23)780-011 Standoff - Top

25)770-074 Standoff

26)

770-128

Sealing Plate

27)

*

Outer Flue Collar

28)

*

Inner Flue Collar Assy

29)

*

Flue Mounting Bracket

30)

*

Gasket for Flue Collar

 

773-528 Brick Panel Base (set of 3)

31)

*

Brick Panel - Base Rear

32)

*

Brick Panel - Base Front

770-901 Brick Panel Set - Standard

Brown

770-902 Brick Panel Set

-Standard Red 770-903 Brick Panel Set

-Herringbone Brown

770-904 Brick Panel Set

-Herringbone Red

33)

*

Brick Panel - Back

34)

*

Brick Panel - Left

35)

*

Brick Panel - Right

36)904-716 #10 x 5/8" Butt Spacer

511-031 Brick Panel Clip

P95-3 MAIN ASSEMBLY

Part # Description

432-967 Burner ON/OFF Switch Assy

38)910-241 Burner ON/OFF - Switch

910-899 Wire Harness - Valve to Burner

42)430-517/P Fan Assembly (120 Volts)

910-331/P Fan Motor (120 Volts)

770-523 Fan Switch Assembly

43)910-813 Power Cord (120 Volts)

46)910-330 Fan Speed Control Switch

47)904-586 Knob - Speed Control

48)910-199 Wire Holder Clip

49)910-142 Thermodisc-Fan Auto On/Off

910-878 Wire Harness - Twin Fan Cable

50)770-994 Dura-Vent Adaptor (Optional)

60)W260260 Top Relief Frame Gasket

61)942-117 Top Relief Plate Frame

62)W260280 Top Relief Plate Gasket

63)770-066 Top Relief Plate

64)

*

Hex Cap Screw 1/4 20NC 3.5

65)

*

Hex Cap Screw 1/4 20NC

2.0

80)

*

Hex Cap Screw 1/4 20NC

1.75

946-556 Heat Wave Duct Kit (Optional)

89)946-004 Junction Box

90)946-000 Round Duct Adaptor

91)946-002 Round to Oval Adaptor

92)946-001 Oval Duct Adaptor

93)946-007 Angle Bracket

Part #

Description

94)946-517/P Fan Assy - HeatWave Option

95)946-006 Grill Plate - White

96)946-005/01 Wall Adaptor Plate - White

97)910-417 Knob - White

98)910-366 Switch Cover Plate - White

99)910-412 Fan Speed Controller

100)910-367 Box-Plastic Switch Receptacle

101)690-022 Cover Plate

102)946-010 Flexible Air Duct

946-045 Insulation 6" dia. x 60"

946-570 Heat Release Duct Kit (Opt.)

108)910-165 Fan (120 V)

109)946-000 Flexible Air Release Duct

918-526 Manual

773-969 Conversion Kit - NG to LP

*Not available as a replacement part.

Excalibur® P95-3 Zero Clearance Direct Vent Gas Fireplace

39

Image 39
Contents 07/17/06 P95-3 Zero Clearance Direct Vent Gas FireplaceTo the New Owner CongratulationsTable of Contents Copy of Safety Decal for P95-3 Safety LabelFor the State of Massachusetts only RequirementsImportant Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistOptional Heat Release KIT Locating Your GAS FireplaceManufactured Mobile Home Additional Requirements Optional Heatwave Duct System KITUnit Base STAND-OFFS Framing DimensionsCombustible Mantels Framing FinishingFloor Mounted Fireplaces Raised Fireplaces Facing RequirementHearth Requirements Facing Over 1 25mm ThickSide Nailing Strips Unit Assembly Prior to InstallationTop Standoff Assembly Venting IntroductionFPI Direct Vent System Flex Horizontal Terminations Only VentingExterior Vent Termination Locations Alternate Horizontal Termination Cap Flat Wall Installation Wall Thickness Vent Length RequiredCorner Installation Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List DescriptionParts not supplied by Dura-Vent FPI Direct Vent System Flex Venting Arrangements Horizontal TerminationsOption + V1 H + H1 Horizontal Venting with Two 2 90o ElbowsHorizontal Venting with Three 3 90o Elbows Option + H1Vertical Venting with Two 2 90o Elbows Vertical Venting with Three 3 90o ElbowsOption Simpson DURA-VENT Direct Vent GS System Venting Arrangements Vertical TerminationsInstallation Snorkel Terminations Below Grade InstallationContinue to assemble pipe lengths Vertical TerminationGS 8 Nominal Diameter ID Offset Installation ProceduresOffset Chart For FPI Direct Vent System FlexHigh Elevation Pilot AdjustmentGAS Line Installation GAS Pipe Pressure TestingInstallation of LPG Conversion Kit Installation of the DC Sparker Heat Shield Optional Brick Panels LOG SET InstallationPicture below is a view from the back of the burner Tab Screw Glass Door InstallationOptional Screen Doors Front FacadeSingle Door Accents Accent KIT InstallationWall Thermostat Thermostat Wire TableDo not cut the ground terminal off under any circumstances Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesMaintenance To Remove the Fans FAN MaintenanceTo Install the Fans Shut the power offInstalling Valve Removing ValveBrick panel is very fragile handle with care P95-3 Main Assembly Parts ListParts List P95-3 Burner Assembly & LOG SET Description P95-3 Flush Front AccessoriesWarranty Limited Lifetime WarrantyInstaller Please complete the following information