Excalibur electronic P95-LP3 Glass Door Installation, Optional Screen Doors, Front Facade

Page 29

INSTALLATION

GLASS DOOR

INSTALLATION

1)Fit top door bracket over the fl ange at the top of the fi rebox.

2)Secure with 3 screws on the bottom.

3)Mount the 2 screws back onto the mounting plate on the rear of the facade through the tab on the glass frame and then tighten screw to secure.

OPTIONAL

SCREEN DOORS

1)Attach door bracket to side using 2 screws to the left and right side of the unit.

Flange

Door

Door Bracket attaches with 2 screws.

Tighten both screws to secure Front

Facade to Glass Door.

2) Slide the door(s) onto the hinges.

Tab

Screw

FRONT FACADE

1)Remove the 2 screws from the mounting plate that are on the back of the facade.

Remove screws from the mount-

ing tabs.

2)Place the Front Facade into position by sliding the 2 holes in the bottom brackets over the pins on the base, one on each side.

View from underneath of the

screw and the bracket.

4)Slide Bottom Louver into position. On each side secure the bottom screw fi rst into the side bracket. Do not overtighten, leave slightly loose to allow the louver to move freely.

Secure

Screw

5)Attach the two control boxes to the bottom unit base and tighten the 2 screws on the left side and 1 screw on the right side.

Adjusting the Plunger: Loosen the screw that holds that plunger bracket so that you can remove the plunger.

Loosen the

screw holding

the bracket.

Once the plunger has been removed take a pin and put it in the hole that is in the round part of the plunger and adjust it accordingly by turning it to the left or right.

Bracket Pin

Fit the bottom brackets over

the pins on the base.

Secure left side with 2 screws and right

side with one screw.

Adjust plunger by turning it to the left or right with a pin.

Excalibur® P95-3 Zero Clearance Direct Vent Gas Fireplace

29

Image 29
Contents 07/17/06 P95-3 Zero Clearance Direct Vent Gas FireplaceTo the New Owner CongratulationsTable of Contents Copy of Safety Decal for P95-3 Safety LabelFor the State of Massachusetts only RequirementsGeneral Safety Information InstallationInstallation Checklist Important Message Save These InstructionsManufactured Mobile Home Additional Requirements Locating Your GAS FireplaceOptional Heatwave Duct System KIT Optional Heat Release KITCombustible Mantels Framing DimensionsFraming Finishing Unit Base STAND-OFFSHearth Requirements Facing RequirementFacing Over 1 25mm Thick Floor Mounted Fireplaces Raised FireplacesTop Standoff Assembly Unit Assembly Prior to InstallationVenting Introduction Side Nailing StripsFPI Direct Vent System Flex Horizontal Terminations Only VentingExterior Vent Termination Locations Corner Installation Flat Wall Installation Wall Thickness Vent Length RequiredSimpson DURA-VENT Venting Alternate Horizontal Termination CapParts not supplied by Dura-Vent Simpson DURA-VENT Venting Components ListDescription FPI Direct Vent System Flex Venting Arrangements Horizontal TerminationsHorizontal Venting with Three 3 90o Elbows Horizontal Venting with Two 2 90o ElbowsOption + H1 Option + V1 H + H1Option Vertical Venting with Two 2 90o ElbowsVertical Venting with Three 3 90o Elbows Simpson DURA-VENT Direct Vent GS System Venting Arrangements Vertical TerminationsInstallation Snorkel Terminations Below Grade InstallationContinue to assemble pipe lengths Vertical TerminationOffset Chart Installation ProceduresFor FPI Direct Vent System Flex GS 8 Nominal Diameter ID OffsetGAS Line Installation Pilot AdjustmentGAS Pipe Pressure Testing High ElevationInstallation of LPG Conversion Kit Installation of the DC Sparker Heat Shield Optional Brick Panels LOG SET InstallationPicture below is a view from the back of the burner Optional Screen Doors Glass Door InstallationFront Facade Tab ScrewSingle Door Accents Accent KIT InstallationWall Thermostat Thermostat Wire TableDo not cut the ground terminal off under any circumstances Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds of GAS AppliancesMaintenance To Install the Fans FAN MaintenanceShut the power off To Remove the FansBrick panel is very fragile handle with care Installing ValveRemoving Valve P95-3 Main Assembly Parts ListParts List P95-3 Burner Assembly & LOG SET Description P95-3 Flush Front AccessoriesWarranty Limited Lifetime WarrantyInstaller Please complete the following information