| TorqueMaster® Spring | |
| Removal Continued... | |
|
| |
Tools Needed: | should be free to rotate in either direction. | |
If the counterbalance cable is still taut and | ||
| ||
Recommended | the TorqueMaster® Spring Tube is difficult | |
to rotate, that is an indication that spring | ||
tools from | ||
tension still exists on the left hand spring. | ||
page 5 | Repeat Steps 1 and 2 for releasing spring | |
| tension on the left hand side. | |
| Step 4: Using a flat tip screwdriver, | |
| pry the counter gear and counter cover | |
| from the right hand end bracket (Fig. 4 | |
| on previous page). Discard the counter | |
| gear and counter cover. On double spring | |
| applications, repeat for left hand side. | |
| Step 5: Remove the upper 5/16” x | |
| ||
| bracket (Fig. 5). Attach locking pliers to | |
| the upper portion of the end bracket and | |
| hold the housing steady while removing | |
| the lower 5/16” x | |
| #10 x 1/2” phillips head screw from the | |
| end bracket (Fig. 6). | |
| Step 6: Holding the right hand end | |
| bracket steady with locking pliers, | |
| carefully pry the end bracket and drive | |
| gear off the winding shaft using a flat tip | |
| screwdriver (Fig. 7). | |
| CAUTION: THE WINDING SHAFT MAY | |
| ROTATE WHEN REMOVING THE END | |
| BRACKET AND DRIVE GEAR. | |
| Step 7: Repeat Step 4 for the left hand | |
| side. Holding the left hand end bracket | |
| steady with locking pliers, carefully pry | |
| the end bracket off the winding shaft | |
| using a flat tip screwdriver (Fig. 7). | |
| Step 8: Remove the two (2) lag bolts | |
| attaching the center bracket assembly to | |
| the header board (Fig. 8). | |
| Step 9: Lift the right hand side of the | |
| TorqueMaster® Spring Tube and slide the | |
| cable drum off. Realign the groove in the | |
| winding shaft with the radial notch in the | |
| flagangle and drape the counterbalance | |
| cable with drum over the flagangle. Lift | |
| the left hand side of the TorqueMaster® | |
| Spring Tube and slide the cable drum | |
| and winding shaft off (Fig. 9). Drape the | |
| counterbalance cable with drum over the | |
| flagangle. Lift the TorqueMaster® spring | |
| assembly off the flagangles and out of | |
| the doorway. Unhook the counterbalance | |
| cables from the bottom brackets and | |
| remove all parts from the work area. | |
| NOTE: The cable drums may be difficult to | |
| remove. If so, twist the cable drum to aid | |
| in removal. | |
| NOTE: Continue with “P4” on page 9 after | |
| completing this step. | |
|
|
Remove top lag screw
Fig. 5
Use locking pliers
to hold end bracket
Remove #10
Phillips head
screw
Remove
bottom lag
screw
Fig. 6
Hold the
end bracket steady with locking pliers
Pry end bracket from winding shaft using a flat tip screw driver and locking pliers
| Fig. 7 | |
CENTER | Remove cable drum and | |
BRACKET | winding shaft | |
ASSEMBLY | ||
|
(2) 5/16” x | Drape cable |
|
|
| Lift | ||
hex head lag | across |
| TorqueMaster® |
screws | Top of flagangle |
| Spring Tube |
|
|
| Off flagangle |
|
|
8Please Do Not Return This Product To The Store. Contact your local
yellow pages business listings or go to the Find a Dealer section online at