Use wall control supplied with operator. Any other wall control can cause the operator to operate unexpectedly and light not to work.

Door starts up, but stops before it￿s completely open.

Be sure door, operator, and springs are in

good repair, properly lubricated and balanced

(See maintenance section).

Check ￿OPEN￿ limit switch setting

(See section ).

Operator does not run from wall control.

Check lock switch on wall console.

Check power source.

Plug a lamp into outlet used for power head If lamp works, power source is OK.

If not, check fuse or circuit breaker.

Power is OK.

Check connections at power head terminals.

Check connections at wall control.

Check wires to ensure they are not cut. Staples can cut insulation and short wires. If wire is cut, replace it.

Check ￿OPEN FORCE￿ adjustment

23

(See section

 

).

 

 

 

Operator runs,

Make sure carriage is engaged to

but door does

carriage slide.

not move.

— Place carriage lever in lock position.

 

Check force adjustment (See section

 

).

 

 

 

Door operator will NOT run more than

 

 

 

30 seconds each way if door does

 

not move.

Door operator

Was a remote control lost or stolen?

starts for

Erase all remote control codes from

no reason.

receiver memory and reprogram

 

(See section

 

 

).

 

 

 

 

Button stuck

on

wall control.

 

Check CLOSE limit switch setting

 

(See section

 

 

).

 

 

 

 

Wires shorted.

 

 

Remote control

Relocate remote control inside car.

has less than

Point remote control at garage door.

25 feet

Replace battery (See section

 

).

 

operating range.

Reposition door operator antenna.

 

 

DO NOT attempt to retune remote controls.

Door starts down, then stops before it￿s closed.

Door starts down, then stops and goes

back up.

Door will only run closed.

Check CONTACT REVERSE (See section ).

Check ￿STB￿ system for beam obstruction or misalignment of lenses (See section ).

Check ￿STB￿ diagnostic code.

Check ￿CLOSE FORCE￿ adjustment (See section ).

Check OPEN limit switch for short and proper wiring.

Check ￿OPEN FORCE￿ adjustment (See section ).

Check door condition and door spring.

Operator works from wall control, but not from remote control.

Noisy operation.

Safe-T-Beam®system malfunction

Program remote control code into receiver memory. (See section ).

Replace remote control battery with good one. (See section ).

Be sure all fasteners are tight.

Be sure door and operator is in good repair, properly lubricated and balanced (See monthly maintenance section).

If an operational problem exists, and operator will not run closed. The operator can be forced

to close as follows (See section

).

Door will only run open

Check ￿STB￿ system (See self-diagnostic ￿STB￿ Troubleshooting Chart).

Check CLOSE limit switch for short and proper wiring.

Check ￿CLOSE FORCE￿ adjustment (See section ).

Disconnect the ￿STB￿ system from the operator.

Hold the wall control button down until door is completely closed.

Use self-diagnostic ￿STB￿ system Troubleshooting information to maintain safe operation.

Lights will not go

Disconnect and reconnect wires on wall control

out

(See section

 

).

 

 

Check wiring.

 

 

 

Incompatible wall control.

If you have any questions, please do not hesitate to contact customer service at:

1.800.354.3643

Image 23
Contents Garage Door Operator PRE-INSTALLATION Check List Typical 1-PIECE Door Installation Typical Sectional Door InstallationSafety Features Table of ContentsOperator Features Parts Identification Not Shown Full Size Recommended ToolsPiece Rail Hardware Exploded View Safety Information Parts ListPower Head Exploded View Operator Assembly Attach emergency release tag Attach rail to power headSlip carriage into carriage slot of rail Slip opposite no knot end through knobAttach limit switch wires Attach limit switchesMarking final height InstallationHeader and Door Mounting Brackets Finding header bracket mounting locationMounting the door bracket Door Bracket12 2. Mounting the header bracket Finding door bracket mounting locationMounting the Operator Attach the arms Connecting the armsSAFE-T-BEAM System Installation Check the following WiringFinding the mounting location Wall Control InstallationInstructions for electrician Connecting to PowerWith Permanent Wiring With Grounded PlugAdjusting Close force Limit Switch / Force AdjustmentAdjusting limit switches Adjusting Open force Contact Reverse Test Programming Remote Controls Single Button RemoteLost or Stolen Remote Light BULB/LENS InstallationMULTI-BUTTON Remote Door balance Maintenance Routine Monthly MaintenanceTroubleshooting Guide Door springs and hardwareDoor operator Operator runsBut door does Not moveTransmitter Compliance Statement Wiring DiagramPlease have part number and credit card ready DistributorGenie Company Garage Door Operator Accessories Order FormLimited Warranty Ayuda Para Temps de combien Pendant Brevets d’autres pour effectuée DemandeMexique au ou Canada au Unis,-Etats aux achetés Genie Produit le acheté initialementConnexion DE Schéma Cableado DE DiagramaRaison sans Mantenimiento de secciónProblème RemonteVerde .L.D Rojo .L.D Problemas DE Solución LA Para GuíaMantenimiento Chariot du Dépannage DE GuideEntretien Verte del Rouge delLente ET Pile DE Changement TélécommandePince LA DE Installation REMOTO, Control DEL InstalaciónInversión DE Contacto DE Prueba Télécommandes DES ProgrammationProgramación DE Remotos Controles ParedFig corredizo Abrir de límiteFuerza LA DE Ajuste / Limitador Interruptor Branchement Eléctrica Alimentación LA ConectarCiego agujero Tornillo VisBorne la à Murale commande la de l’arrière ÀMurales Commandes DES Installation Pared DE Control DEL InstalaciónControl de AjustadasNecesario Sensor del’extension BEAM-T-SAFE Systeme DU InstallationBEAM-T-SAFE Sistema DEL Instalación 1 x 16-#1012-2 .Fig Porte LA DE Bras LES InstallerOperador DEL Montaje Garde EN Mise PrecauciónPorte DE Montage DE ET Linteau DE Supports InstallaciónInstallation Puerta LA DE Montaje DEL Travesaño DEL CartelasRail Riel delRail du Esquina 7,-1 .FigDeuxième Operador DEL Conjunto’OPÉRATEUR DE Assemblage TroisièmeMotorisée Tète Éclatée VUE Control DE Caja LA DE Piezas DE ListaPiezas DE Lista Seguridad DE InformaciónArt Sécurité LA À Relatives InformationsPièces DES Nomenclature Motorisée Tète LA DE Pièces DES NomenclatureÉclatée VUE Rail DU Quincaillerie Éclatée VUE Rail DU QuincaillerieRiel DEL Herraje DEL Aumentada Vista Riel DEL Herraje DEL Aumentada VistaRecomendar Herramientas Recommande OutilsSujetadores Attaches Piezas DE IdentificaciónModelos algunos con incluido Operador DEL Características ÍndiceSeguridad DE Características Modelos algunos con incluida iluminada pared de ConsolaMatières DES Table Sécurité DE Caractéristiques’OPÉRATEUR DE Caractéristiques Monopièce Porte DE Installation De sistema del montaje de lugar el si ver para Verificar Votre sur l’installation pour 2-GER d’urgence déclenchementDe obligé certainement serez Vous .montage de emplacement Lentamente muy bajar o está, donde quedarse debe puerta LaPuertas de