Frymaster BIELA14 warranty 4.7M3000 Button Description and Functions, Navigation Buttons

Page 25
4.7M3000 Button Description and Functions

4.7M3000 Button Description and Functions

4.7.1 Navigation Buttons

The menu on the M3000 uses 34and tu buttons to navigate the various menus and submenus.

When programming, the left screen shows a menu or submenu item. The right screen is for data entry. Data is

entered with alpha-numeric characters, scrolling through Left Display Right Display lists or by toggling between choices.

During programming if a button is not pushed within one minute, the computer returns to operation mode.

4.7.2 Filter, Temperature and Info Buttons

The < FLTR and FLTR > buttons (see Figure 1) are used to filter the left and right vats of a split vat or a full vat fryer on demand. The FLTR buttons, if pressed once displays the number of cook cycles remaining until a filtration prompt. When the FLTR button is pressed twice, the date and time of the last filter is displayed. The TEMP button, if pressed once while the fryer is on,

displays current vat temperature on both sides. If the TEMP button is pressed twice while the fryer is on, it shows the setpoint temperatures of the vats. If the fryer is off, the display shows the current

versions of software. The INFO button (see Figure 1), if pressed once when the fryer is on, shows the recovery time for each vat from the last test. Recovery is the time required for the fryer to raise the temperature of the oil 50°F (28°C) between 250°F (121°C) and 300°F (149°C). Maximum

recovery time should not exceed 1:40 for electric or 2:25 for gas. If the INFO button is pressed and held for three seconds it shows information such as usage, filter statistics and last cook cycles (see page 4-34 for more details on the INFO button).

4.7.3 Cook Channel and Selection Buttons

The

buttons are dual-function buttons shared with

the number 1 and 2 buttons. They are located directly below the LED displays. Use these buttons to select or

cancel functions. The button is used to back out of and exit submenus.

4-7

Image 25
Contents FRYMASTER BIELA14 SERIES GEN II LOV OPERATOR’S MANUALELECTRIC FRYER FOR YOUR SAFETYNOTICE TO U.S. CUSTOMERS NOTICENOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS CANADADANGER Adding New Product Menu Items Product Selection M3000 Menu Summary TreeSee section 4.10.2B.WARRANTY PROVISIONS - FRYPOTS A.WARRANTY PROVISIONS - FRYERSD.WARRANTY EXCLUSIONS C.PARTS RETURN•overtime or holiday charges This warranty also does not coverBIELA14 SERIES GEN II LOV ELECTRIC FRYER 1.2Safety InformationCHAPTER 1: INTRODUCTION 1.1General1.3Computer Information for the M3000 Computers 1.5Installation, Operating, and Service Personnel1.4European Community CE Specific Information CE StandardWhat to do if your equipment arrives damaged 1.7Shipping Damage Claim Procedure1.8Service Information NOTICE 2.1General Installation Requirements2.1.2 Electrical Grounding Requirements 2.1.3 Australian Requirements 2.2Power RequirementsDANGER CHAPTER 3: OPERATING INSTRUCTIONS TYPICAL CONFIGURATION BIELA314 SHOWNM3000 COMPUTER 3.1Equipment Setup and Shutdown Procedures3.3.2 Install the Oil Reservoir 3.3 Low Oil Volume Automatic Refill3.3.1 Prepare the System for Use 3.3.3 Routine Oil Changes3.3.4Bulk Oil Systems FR FRIES 4.1M3000 General Information4.2Basic Operation 4.3Cooking with Multi-ProductDisplay 4.4Cooking with Dedicated Display <<<< >>>> 4.5Changing from Breakfast Setup to Lunch<<<<>>>>; an alarm will sound Press and quickly4.6Changing from Lunch Setup to Breakfast 4.7.1 Navigation Buttons 4.7M3000 Button Description and Functions4.7.2 Filter, Temperature and Info Buttons 4.7.3 Cook Channel and Selection ButtonsSee section 4.8M3000 Menu Summary Tree4.10.2 4.10.31234 4.9Fryer Setup Mode Programming24hR 4.10.1 Escape Menu Items 4.10 M3000 Common Tasksfull 1.Escaping out of a menu or sub-menuproduct selectionPROD COOK ID DISABLE Product selection prompt 4.10.3 Storing Menu Items in Product Buttons4.10.4.1 Disposal for Non-BulkOil Systems 4.10.4.2 Refilling JIB Oil Systems 2. Press the u INFO button and scroll to dispose When finished, the computer displays REMOVE PAN4. To dispose press the 1 yes button to continue The computer displays DRAINING4.11 Filter Menu 4.11.1 Accessing the Filter Menua. auto filter b. maint filter4.11.2 Drain to Pan yes no 4.11.3 Fill Vat from Drain Pan4.11.4 Fill Vat from Bulk 4.11.5 Pan to Waste 4.12 Programming Level Onee. Fryer setup c. DEEP CLEAN MODEa.disabled b.enabled 4.12.1 AIF CLOCKselection display 4.12.2DEEP CLEAN MODE BOIL-OUTYes No EMPTY? and Yes NO DANGER 4.12.3 HIGH-LIMITTEST MODE comp 4.13 Programming Level Two4.13.1 PRODUCT COMP MODE c. password SETUPa. Prod comp b. e-log4.13.2 E-LOGMODE 4.13.3 PASSWORD SETUP MODE4.13.4 ALERT TONE MODE 4.13.5 FILTER AFTER 4.13.6 FILTER TIME 4.14 INFO ModeSPLIT VAT CONFIGURATION FULL VAT CONFIGURATION4.14.1 FILTER STATS MODE a. filter statsa. DAY wed, DATE 03/20/07 – Current day and date 4.14.2 REVIEW USAGE MODE4321 FULL / SPLIT VAT CONFIGURATION4.14.3LAST LOAD MODE 4-38 5.Press the 2 button again to quit5.1Introduction CHAPTER 5: FILTRATION INSTRUCTIONSThe filter pad or paper MUST be replaced daily 5.2Preparing the Filter for Use5.3 Auto Intermittent Filtration AIF 5.3.1 Auto Demand Filtration DRAINING, WASHING and FILLING during the process2. Press the 9 1 yes button to continue 9.Press 9 1 yes to silence alarm and continue prompt for SYSTEM ERROR 5.4.4 Filter Error Flowchart5.5Manual or End of Day Filtration MAINT FLTR 5.4.5 Filter BusyThe filter pad or paper must be replaced daily 2.Press the uINFO button to scroll to maInT fIltEr 9. Press the 9 1 yes button to continue 6.1.2Clean the Built-inFiltration System – Daily 6.1Cleaning the Fryer DANGER6.1.3Clean Behind Fryers – Weekly Replace the O-rings Deep Clean Boiling Out the Frypot6.2Annual/Periodic System Inspection FryerBuilt-InFiltration System 7.1 Introduction Problem Problem7.2Troubleshooting 7.2.1 Computer and Heating Problems7.2.3 Filtration Problems Corrective Action 7.2.4 Auto Top-OffProblemsError Log Codes 7.2.5 Bulk Oil System ProblemsProbable Causes 7.2.6is missing 8.1Wiring Diagrams 8.1.1Component Wiring Domestic CHAPTER 8: WIRING DIAGRAMS8.1.2Component Wiring CE 8.1.3Component Wiring CSA 8.1.4Component Wiring Australia 8.1.5Contactor Box – Delta Configuration 8.1.6 Contactor Box – WYE Configuration START OF 6-WIRE DATA & POWER 8.1.7 BIELA14 Series GEN II LOV Simplified Wiring8051734Q Page NOTE: Do NOT overfill the jug A.1.1 Bulk Oil SystemsFigure 2: Position the melter APPENDIX C: Solid Shortening Melter Use FAX Parts SERVICE HOTLINEFAX Tech Support 1-800-551-8633
Related manuals
Manual 26 pages 13.97 Kb Manual 96 pages 23.21 Kb