●Verify that the tilt mechanism is working properly when lifting and lowering elements and that the element wires are not binding and/or chafing.
●Verify the
●Verify that the temperature and
●Verify that component box and contactor box components (i.e. computer/controller, relays, interface boards, transformers, contactors, etc.) are in good condition and free from oil and other debris.
●Verify that component box and contactor box wiring connections are tight and that wiring is in good condition.
●Verify that all safety features (i.e. contactor shields, reset switches, etc.) are present and functioning properly.
●Verify that the frypot is in good condition and free of leaks and that the frypot insulation is in serviceable condition.
●Verify that all wiring harnesses and connections are tight and in good condition.
Built-In Filtration System
●Inspect all
●Inspect the filter pan for leaks and cleanliness. If there is a large accumulation of crumbs in the crumb basket, advise the owner/operator that the crumb basket should be emptied into a fireproof container and cleaned daily.
●Verify that all
●Check filtration system integrity as follows:
−Verify that filter pan cover is present and properly installed.
−With the filter pan empty, place each vat into fill vat from drain pan selection, one at a time. Verify proper functioning of each oil return valve by activating the filter pump using the return to pan selection. Verify that the pump activates and that bubbles appear in the cooking oil of the associated frypot.
−Verify that the filter pan is properly prepared for filtering with a clean filter pad, then drain a frypot of oil heated to 350°F (177°C) into the filter pan by using the drain to pan selection (see page