9.Press the u (INFO) button. The computer displays 0 DUR. This is the amount of time the AIF is to remain suspended.
10.Use the number keys to enter a time between 0 and 999 minutes (ex. 1½ hours is entered as 90 minutes). Enter
90 for this example. The computer displays 090 DUR. Four different time periods to suspend filtration are available for each day or set of days.
11.Press the u (INFO) button to accept time and move to the next time period.
12. When finished, press the | button once to exit and return to PRODUCT |
selection display. |
|
13.Press the (2) button to quit and to return to OFF.
4.12.2DEEP CLEAN MODE (BOIL-OUT)
The deep clean mode is used to remove carbonized oil from the frypot.
NOTE: Refer to Kay Chemical “Fryer Deep Clean Procedure” instructions to clean the LOV™ fryer.
1.Perform steps
2. Press the (1 yes) button.
Bulk Oil System: Ensure a complete and clean filter pan is in place.
JIB Oil System: Ensure an MSDU or suitable metal container is in place under the drain with a capacity of FOUR gallons (15 liters) or more.
The computer displays DEEP CLEAN? alternating with yes no. 3. Press the (1 yes) button.
4.Full Vat: Computer displays IS Oil REMOVED? alternating with
Yes No.
Split Vat: Computer displays Deep Clean alternating with L R.
Press the (1) or (2) button under the split vat to be cleaned. The computer displays IS OIL REMOVED? alternating with yes no*.