18.Bulk or JIB System: The computer displays SCRUB VAT COMPLETE? alternating with yes. Press the 9 (1 yes) button.
19.Bulk or JIB System: The computer displays DRAINING. The drain opens to drain the small amount of residual solution left in the vat. Rinse excess solution from vat.
20.Bulk or JIB System: The computer displays Rinse complete?
alternating with yes. Press the 9 (1 yes) button to continue when the vat is completely rinsed.
21.Bulk or JIB System: The computer displays REMOVE PAN. Remove the filter pan.
22.Bulk or JIB System: The computer displays VAT and pan DRY?, alternating with yes. Ensure the vat and pan are completely dry.
DANGER
Ensure that the frypot and filter pan are completely dry and free of water before filling with oil. Failure to do so will cause splattering of hot liquid when the oil is heated to cooking temperature.
23.Bulk or JIB System: The computer displays INSERT pan. Reinstall screen, filter pad, hold down ring and crumb basket removed in step 16. Insert the filter pan.
24.JIB system: The computer displays MANUAL FILL alternating with
yes. Press the 9 (1 yes) button and display returns to OFF.
Bulk system: Go to Section 4.11.4 Fill Vat From Bulk on page
4.12.3 HIGH-LIMIT TEST MODE
The
The test is cancelled at any time by turning the fryer off. When the fryer is turned back on, it returns to the operating mode and displays the product.
1. Perform steps
Computer displays hi limit test.
2. Press the 9 (1 yes) button to continue the
The computer displays
3.Press the 9 (1 yes) button to continue the test. If performing the test on a split vat press the 9 (1 yes) button on the side which corresponds to the vat.
The computer displays press and h0ld check.
4. Press and hold the 9 (1 yes) button to initiate the