*If the bulk oil system waste tank is full, the computer displays RTI TANK FULL alternating with CONFIRM. Press the (1) button and call the bulk oil waste provider. The display returns to OFF.
DANGER
When draining oil into a disposal unit, do not fill above the maximum fill line located on the container.
DANGER
Allow oil to cool to 100°F (38°C) before draining into an appropriate METAL container for disposal.
DANGER
When draining oil into an appropriate MSDU or METAL container, make sure the container will hold at least FOUR gallons (15 liters) or more. Otherwise oil could overflow and can cause injury.
5. Empty fry vat: Press the | (1 yes) button and skip to step 12. |
(2 no) button. |
6.JIB Oil System: The computer displays is Disposal unit in place? alternating with yes no. Ensure an MSDU or suitable metal
container is in place under the drain with a capacity of FOUR gallons (15 liters) or larger is in place. Press the (1 yes) button to dispose the oil. The computer displays disposing ending with VAT EMPTY? alternating with YES. Press the (1 yes) button and skip to step 12.
Bulk* Oil System: Computer displays DRAINING. Once the oil has
drained into the filter pan the | computer displays Vat empty? |
alternating with yes. Press the | (1 yes) button and continue. |
*If INSERT PAN is displayed, remove and replace the filter pan.
Bulk Oil System: The computer displays OPEN DISPOSE VALVE.
7.Bulk Oil System: Open the left cabinet door and unlock the lock if necessary. Pull the dispose valve completely forward to start disposal.
Bulk Oil System: The computer displays DISPOSING for four minutes.
The pump transfers the waste oil from the pan to the bulk oil waste tanks.
Bulk Oil System: When finished, the computer displays REMOVE
PAN.
8. Bulk Oil System: Remove the filter pan and ensure the pan is empty. Bulk Oil System: The computer display alternates between IS PAN