5.4.5 Filter Busy
When FILTER BUSY is displayed the MIB board is waiting on another vat to be filtered or waiting on another issue to clear. Wait 15 minutes to see if problem is corrected. If not, call your local ASA.
DANGER
Do not drain more than one frypot at a time into the
WARNING
The filter pump is equipped with a manual reset switch in case the filter motor overheats or an electrical fault occurs. If this switch trips, turn off power to the filter system and allow the pump motor to cool 20 minutes before attempting to reset the switch (see photo below).
WARNING
Use caution and wear appropriate safety equipment when resetting the filter pump reset switch. Resetting the switch must be accomplished with care to avoid the possibility of a serious burn from careless maneuvering around the drain tube and frypot.
Filter Pump Reset Switch
5.5Manual or End of Day Filtration (MAINT FLTR)
NOTICE
The filter pad or paper must be replaced daily.
DANGER
Do not drain more than one frypot at a time into the
Ensure that the filter pad or paper is replaced daily to keep the system operating correctly.
1.The fryer MUST be at setpoint temperature. With the computer ON press and hold the FLTR button for three seconds.