| is missing |
E12 | ERROR RETURN VALVE NOT OPEN | Return valve was trying to open and confirmation |
|
| is missing |
E13 | ERROR RETURN VALVE NOT CLOSED | Return valve was trying to close and confirmation |
|
| is missing |
E14 | ERROR AIF BOARD | MIB detects AIF missing; AIF board failure |
E15 | ERROR MIB BOARD | Cooking computer detects MIB connections lost; |
|
| Check software version on each computer. If |
|
| versions are missing, check CAN connections |
|
| between each computer; MIB board failure |
E16 | ERROR AIF PROBE | AIF RTD reading out of range |
E17 | ERROR ATO PROBE | ATO RTD reading out of range |
E18 | Not used |
|
E19 | M3000 CAN TX FULL | Connection between computers lost. Check for |
|
| loose CAN cables between computers and MIB |
|
| board. Check software version by pressing the |
|
| TEMP button with the computers displaying OFF. |
|
| If a computer displays only M3000 software, the |
|
| computer may be defective. |
E20 | INVALID CODE LOCATION | SD card removed during update |
E21 | FILTER PAD PROCEDURE ERROR | 25 hour timer has expired or dirty filter logic has |
| (Change Filter Pad) | activated |
E22 | OIL IN PAN ERROR | The MIB has reset the oil in pan flag. |
E23 | CLOGGED DRAIN (Gas) | Vat did not empty during filtration |
E24 | AIF BOARD OIB FAILED (Gas) | Oil is back sensor failed. |
E25 | RECOVERY FAULT | Recovery time exceeded maximum time limit. |
E26 | RECOVERY FAULT CALL SERVICE | Recovery time exceeded maximum time limit for |
|
| two or more cycles. |
E27 | LOW TEMP ALARM | Oil temperature has dropped lower than 15°F |
|
| (8°C) in idle mode or 45°F (25°C) in cook mode. |