BIELA14 SERIES GEN II LOV™ ELECTRIC FRYER
CHAPTER 5: FILTRATION INSTRUCTIONS
5.1Introduction
The FootPrint Pro filtration system allows the oil in one frypot to be safely and efficiently filtered while the other frypots in a battery remain in operation.
Section 5.2 covers preparation of the filter system for use. Operation of the system is covered in Section 5.3.
WARNING
The
WARNING
The filter pad or paper MUST be replaced daily.
5.2Preparing the Filter for Use
1.Pull the filter pan out from the cabinet and remove the crumb tray,
ring, filter pad (or paper), and filter screen. (See Figure 1) Clean all metal parts with a solution of All Purpose Concentrate and hot water then dry thoroughly.
The pan cover must not be removed except for cleaning, interior access, or to allow a shortening disposal unit (MSDU) to be positioned under the drain. If using an MSDU built before January 2004 see instructions on page 4- 16.
Figure 1
2.Inspect the filter pan connection fitting to ensure that both
Inspect the filter connection fitting
Figure 2