CONNECTING THE RANGE
Electric Supply
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.
In Canada the range must be installed in accordance with the current CSA Standard C22.1 - Canadian Electrical Code Part 1.
Electrical Supply Connection
The range requires 120 volts, 60 cycle alternating current from a grounded outlet with a 15 amp circuit breaker. See serial plate for rating, located on
Electrical Grounding Instructions
This appliance is equipped with a
DISCONNECT ELECTRICAL SUPPLY BEFORE SERVICING THE APPLIANCE.
MANIFOLD
OVEN GAS
FIGURE 3
Gas Supply
Installation of this range must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI
In Canada the range must be installed in accordance with the current CGA Standard
NOTE: If oven burners do not ignite, check oven gas
Oven Gas Shut-Off Valve (See figure 3)
1.Remove rear burner knob.
2.Remove spill guard.
3.Rotate to 9:00 position to turn on and 12:00 position to turn off.
Checking Pressure Of House Piping System
1.The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 lbs./sq. in. (3.5 kPa) (13.8 in. water column).
2.The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 lbs./sq. in. (3.5 kPa) (13.8 in. water column).
Gas Supply Connection (See figure 4)
A TRAINED SERVICEMAN OR GAS APPLIANCE INSTALLER MUST MAKE THE GAS SUPPLY CONNECTION. Leak testing of the appliance shall be conducted by the installer according to the instructions given in section h.
NATURAL GAS SUPPLY LINE MUST HAVE A NATURAL GAS SERVICE REGULATOR. INLET PRESSURE TO THIS APPLIANCE SHOULD BE REDUCED TO A MAXIMUM OF 14 INCHES WATER COLUMN (0.5 POUNDS PER SQUARE INCH (P.S.I.) LIQUEFIED PETROLEUM (L.P.)/PROPANE GAS SUPPLY LINE MUST HAVE A L.P. GAS PRESSURE REGULATOR. INLET PRESSURE TO THIS APPLIANCE SHOULD BE REDUCED TO A MAXIMUM OF 14 INCHES WATER COLUMN (0.5 P.S.I.). INLET PRESSURES IN EXCESS OF 0.5 P.S.I. CAN DAMAGE THE APPLIANCE PRESSURE REGULATOR AND OTHER GAS COMPONENTS IN THIS APPLIANCE AND CAN RESULT IN A GAS LEAK.
NOTE: This range is shipped from the factory set for Natural Gas at 5 water column pressure.
Gas supply pressure for testing regulator must be at least 1 water column pressure above manifold pressure shown on serial plate.