If conversion to LP Gas is required, convert regulator before installation. Oven/broil and top burner conversion can be made from front of range.
a. A GAS
b. The house piping and/or range connector used to connect the range to the main gas supply must be clean, free of metal shavings, rust, dirt and liquids (oil or water). Dirt, etc. in the supply lines can work its way into the range manifold and in turn cause failure of the gas valves or controls and clog burners and/or pilot orifices.
CAUTION: DO NOT LIFT OR MOVE RANGE BY GRASPING MAIN TOP, DOOR HANDLES, OR BACKGUARD.
c.Turn off all pilots and main gas valve of other gas appliances.
d.Turn off main gas valve at meter.
e. Before connecting range, apply pipe thread compound approved for LPG to all threads.
f.Use only a flexible connector to connect range to gas supply at appliance pressure regulator using adaptors supplied with connector. Regulator supplied with range has 1/2 NPT female connection.
NOTE: It is recommended to use a CSA certified flexible connector no longer than 36 (91.4 cm) with a minimum BTU/HR rating of 88,200.
See serial plate for type of gas range has been manufactured for, located on
g. Turn on main gas valve at meter, and relight pilots at other gas appliances.
h. Apply a
CAUTION: NEVER CHECK FOR LEAKS WITH A FLAME.
WHEN LEAK CHECK IS COMPLETE, WIPE OFF ALL RESIDUE.
ADAPTOR
FLEXIBLE CONNECTOR
ADAPTOR
REGULATOR
FIGURE 4